28 July 2022 in Optics Express
Impulsive stimulated Brillouin spectroscopy (ISBS) plays a critical role in investigating mechanical properties thanks to its fast measurement rate. However, traditional Fourier transform-based data processing cannot decipher measured data sensitively because of its incompetence in dealing with low signal-to-noise ratio (SNR) signals caused by a short exposure time and weak signals in a multi-peak spectrum. Here, we propose an adaptive noise-suppression Matrix Pencil method for heterodyne ISBS as an alternative spectral analysis technique, speeding up the measurement regardless of the low SNR and enhancing the sensitivity of multi-component viscoelastic identification. The algorithm maintains accuracy of 0.005% for methanol sound speed even when the SNR drops 33 dB and the exposure time is reduced to 0.4 ms. Moreover, it proves to extract a weak component that accounts for 6% from a polymer mixture, which is inaccessible for the traditional method. With its outstanding ability to sensitively decipher weak signals without spectral a priori information and regardless of low SNRs or concentrations, this method offers a fresh perspective for ISBS on fast viscoelasticity measurements and multi-component identifications.
19 December 2022 in Applied Physics Letters
The elasto-optic coefficient, which describes the interaction of acoustic waves and light in a medium, allows a contrast mechanism in optomechanics. However, the non-contact measurement is a challenge, limiting the study of some materials such as liquids. We present a high-speed non-contact method based on laser-induced phonons. The elasto-optic coefficients of common liquids are measured with only 10 ms and an averaged relative standard deviation of 1.52%, complementing the rare liquid data. By deciphering Brillouin spectra, the elasto-optic coefficient and viscoelastic parameters can be obtained simultaneously, and the introduction of the elasto-optic coefficient makes the characterization more sensitive. Benefiting from spatially resolved measurement, the elasto-optic coefficient is mapped to provide another contrast mechanism for mechanical imaging and may prove useful to characterize biological cells and tissues.
25 March 2024 in Photonics Research
Brillouin microscopy, which maps the elastic modulus from the frequency shift of scattered light, has evolved to a faster speed for the investigation of rapid biomechanical changes. Impulsive stimulated Brillouin scattering (ISBS) spectroscopy has the potential to speed up measurement through the resonant amplification interaction from pulsed excitation and time-domain continuous detection. However, significant progress has not been achieved due to the limitation in signal-to-noise ratio (SNR) and the corresponding need for excessive averaging to maintain high spectral precision. Moreover, the limited spatial resolution also hinders its application in mechanical imaging. Here, by scrutinizing the SNR model, we design a high-speed ISBS microscope through multi-parameter optimization including phase, reference power, and acquisition time. Leveraging this, with the further assistance of the Matrix Pencil method for data processing, three-dimensional mechanical images are mapped under multiple contrast mechanisms for a millimeter-scale polydimethylsiloxane pattern immersed in methanol, enabling the identification of these two transparent materials without any contact or labeling. Our experimental results demonstrate the capability to maintain high spectral precision and resolution at a sub-millisecond integration time for one pixel. With a two-order improvement in the speed and a tenfold improvement in the spatial resolution over the state-of-the-art systems, this method makes it possible for ISBS microscopes to sensitively investigate rapid mechanical changes in time and space.
6 April 2023 in Physical Review Applied
Open-path dual-comb spectroscopy has emerged as a promising technique for regional multigas monitoring with its conspicuous advantages of broadband spectral coverage, high spectral resolution, and rapid update rate. However, it is challenging to realize its full potential due to the undesirable mutual coherence of the dual-comb source and turbulence in the air path, which hinder it from field-deployed open-path applications. Here, phase-sensitive open-path dual-comb spectroscopy based on free-running combs is reported, in which dual-purpose compensation is proposed to provide immunity against both the time jitter of comb sources and turbulent noise. Broadband and high-fidelity atmospheric amplitude and phase spectra containing gas absorption and dispersion information over a 900-m turbulent air path are acquired. For the rovibrational resonances of and in 6250–6660 , the achieved residual of the amplitude spectrum is no more than 0.01, and the average residual of the phase spectrum is 0.2 mrad, corresponding to about 0.2 as of relative timing noise or a refraction-index change of about 6 × over the target path. The precision of concentration retrieval is about 3 ppm for in 30 s. A simulated gas-leakage measurement validates the dynamic monitoring capability of this system. This highly effective noise-compensation method provides the possibility of deploying the portable configuration and holds the potential to propel environmental protection and atmospheric science.
25 September 2024 in Biomedical Optics Express
We present the use of stimulated Brillouin scattering spectroscopy to achieve rapid measurements of cell biomechanics in a flow cytometer setup. Specifically, our stimulated Brillouin scattering flow cytometry can acquire at a rate of 200 Hz, with a spectral acquisition time of 5 ms, which marks a 10x improvement compared to previous demonstrations of spontaneous Brillouin scattering flow cytometry. We experimentally validate our stimulated Brillouin scattering flow cytometer by measuring cell populations of normal breast epithelial cells and metastatic breast epithelial cancer cells.
19 September 2019 in Applied Optics
One of the greatest challenges of long distance measurement is the beam drift caused by the air refractive index gradient. It has been established in many researches that optical phase conjugation (OPC) can be used to compensate for the beam bending. However, this method is limited to responding speed, phase conjugate reflectivity, flexibility, and specific source and medium. To reduce beam drift, instead of OPC, this study applies a digital OPC (DOPC) method, which is also creatively applied to collimation and flatness measurements. The main devices in the wavefront correction unit are the spatial light modulator and the Shack–Hartmann wavefront sensor. For the straightness measurement unit, the collimation and flatness of the optical rail are measured through the prism system and a position-sensing detector. After wavefront compensation, the root mean square is decreased from to . The beam drift is decreased from 1.22 mm to 0.70 mm in the direction and from 2.49 mm to 1.55 mm in the direction. The experimental data indicate that the straightness measurement system based on DOPC can effectively decrease the beam drift.