To characterize focal biomechanical differences between normal, keratoconic, and post-laser vision correction (LVC) corneas using motion-tracking Brillouin microscopy. Prospective cross-sectional study. Thirty eyes from 30 patients (10 normal controls [Controls], 10 post-LVC, and 10 stage I or II keratoconus [KC]) had Scheimpflug and motion-tracking Brillouin microscopy imaging using a custom-built device. Mean, maximum (max) and minimum (min) Brillouin shift, spatial standard deviation, and max-min values were compared. Min values were correlated with local Brillouin values at multiple Scheimpflug imaging locations. Mean (P < .0003), min (P < .00001), spatial standard deviation (P < .01), and max-min (P < .001) were significantly different between the groups. In post hoc pairwise comparisons, the best differentiators for group comparisons were mean (P = .0004) and min (P = .000002) for Controls vs KC, min (P = .0022) and max-min (P = .002) for Controls vs LVC, and mean (P = .0037) and min (P = .0043) for LVC vs KC. Min (area under the receiver operating characteristic = 1.0) and mean (area under the receiver operating characteristic = 0.96) performed well in differentiating Control and KC eyes. Min values correlated best with Brillouin shift values at the thinnest corneal point (r2 = 0.871, P = .001) and maximum keratometry value identified in the tangential curvature map (r2 = 0.840, P = .002). Motion-tracking Brillouin microscopy effectively characterized focal corneal biomechanical alterations in LVC and KC and clearly differentiated these groups from Controls. Primary motion-tracking Brillouin metrics performed well in differentiating groups as compared with basic Scheimpflug metrics, in contrast to previous Brillouin studies, and identified focal changes after LVC where prior Brillouin studies did not.
Corneal biomechanics play a critical role in maintaining corneal shape and thereby directly influence visual acuity. However, direct corneal biomechanical measurement in-vivo with sufficient accuracy and a high spatial resolution remains an open need. Here, we developed a three-dimensional (3D) motion-tracking Brillouin microscope for in-vivo corneal biomechanics mapping. The axial tracking utilized optical coherence tomography, which provided a tracking accuracy better than 3 µm. Meanwhile, 10 µm lateral tracking was achieved by tracking pupils with digital image processing. The 3D tracking enabled reconstruction of depth-dependent Brillouin distribution with a high spatial resolution. This superior technical performance enabled the capture of high-quality mechanical mapping in vivo even while the subject was breathing normally. Importantly, we improved Brillouin spectral measurements to achieve relative accuracy better than 0.07% verified by rubidium absorption frequencies, with 0.12% stability over 2000 seconds. These specifications finally yield the Brillouin measurement sensitivity that is required to detect ophthalmology-relevant corneal biomechanical properties.
1 September 2016 in Review of Scientific Instruments
We propose a stable method for repetition rate multiplication of a 250-MHz Er-fiber frequency comb by a phase-locked all-pass fiber ring resonator, whose phase-locking configuration is simple. The optical path length of the fiber ring resonator is automatically controlled to be accurately an odd multiple of half of the original cavity length using an electronical phase-locking unit with an optical delay line. As for shorter cavity length of the comb, high-order odd multiple is preferable. Because the power loss depends only on the net-attenuation of the fiber ring resonator, the energetic efficiency of the proposed method is high. The input and output optical spectrums show that the spectral width of the frequency comb is clearly preserved. Besides, experimental results show less pulse intensity fluctuation and 35 dB suppression ratio of side-modes while providing a good long-term and short-term frequency stability. Higher-order repetition rate multiplication to several GHz can be obtained by using several fiber ring resonators in cascade configuration.
Brillouin microscopy, which maps the elastic modulus from the frequency shift of scattered light, has evolved to a faster speed for the investigation of rapid biomechanical changes. Impulsive stimulated Brillouin scattering (ISBS) spectroscopy has the potential to speed up measurement through the resonant amplification interaction from pulsed excitation and time-domain continuous detection. However, significant progress has not been achieved due to the limitation in signal-to-noise ratio (SNR) and the corresponding need for excessive averaging to maintain high spectral precision. Moreover, the limited spatial resolution also hinders its application in mechanical imaging. Here, by scrutinizing the SNR model, we design a high-speed ISBS microscope through multi-parameter optimization including phase, reference power, and acquisition time. Leveraging this, with the further assistance of the Matrix Pencil method for data processing, three-dimensional mechanical images are mapped under multiple contrast mechanisms for a millimeter-scale polydimethylsiloxane pattern immersed in methanol, enabling the identification of these two transparent materials without any contact or labeling. Our experimental results demonstrate the capability to maintain high spectral precision and resolution at a sub-millisecond integration time for one pixel. With a two-order improvement in the speed and a tenfold improvement in the spatial resolution over the state-of-the-art systems, this method makes it possible for ISBS microscopes to sensitively investigate rapid mechanical changes in time and space.
A comb-based active laser ranging scheme is proposed for enhanced distance resolution and a common time standard for the entire system. Three frequency combs with different repetition rates are used as light sources at the two ends where the distance is measured. Pulse positions are determined through asynchronous optical sampling and type II second harmonic generation. Results show that the system achieves a maximum residual of 379.6 nm and a standard deviation of 92.9 nm with 2000 averages over 23.6 m. Moreover, as for the frequency transfer, an atom clock and an adjustable signal generator, synchronized to the atom clock, are used as time standards for the two ends to appraise the frequency deviation introduced by the proposed system. The system achieves a residual fractional deviation of 1.3 × 10−16 for 1 s, allowing precise frequency transfer between the two clocks at the two ends.
26 February 2026 in American Journal of Ophthalmology
To compare the diagnostic efficacy of motion-tracking (MT) Brillouin microscopy with multimodal corneal imaging for keratoconus suspect (KCS) identification. Prospective, cross-sectional diagnostic evaluation. There were 56 eyes from 56 patients evaluated, including 28 eyes from 28 bilaterally normal control patients and 28 eyes from 28 keratoconus suspect patients. All patients underwent MT Brillouin microscopy using a custom-built device, Scheimpflug tomography, anterior segment optical coherence tomography (AS-OCT), and Corneal Visualization Scheimpflug Technology (Corvis ST). MT Brillouin microscopy data included mean (MTB-mean) and focal minimum (MTB-min) values within the anterior plateau region. The sensitivity, specificity, and area under the receiver operating characteristic curves (AUROC) were calculated for variables from all modalities. No significant demographic differences were found between groups except thinnest corneal thickness (556 μm Control vs 526 μm KCS; P < .001). MT Brillouin metrics MTB-min (AUC = 0.999, Sensitivity 100%, Specificity 96%) and MTB-mean (AUC 0.981, Sensitivity 93%, Specificity 100%) outperformed all other multimodal imaging metrics in KCS identification and group differentiation. MTB-min significantly outperformed all multimodal metrics, including the Corvis ST Tomographic and Biomechanical Index (TBI) (AUC 0.906, P = .018), Pentacam Random Forest Index (PRFI) (AUC 0.870, P = .005), Keratoconus Index (KI) (AUC 0.873, P = .005), and Index of Height Decentration (IHD) (AUC 0.859, P = .005). The best epithelial metric, Epi 5 mm ST-IN, performed poorly in group differentiation (AUC = 0.641). Motion-tracking Brillouin microscopy metrics effectively identified focal corneal weakening in keratoconus suspects and significantly outperformed all multimodal imaging metrics in differentiating keratoconus suspect eyes from normal controls.