Markus Ruben Pietsch

Markus Ruben Pietsch

Auto-generated profile, based on publicly available information

Markus Ruben Pietsch

Technical University of Munich, Chair of Technical Electrochemistry

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
BSBjörn M. Stühmeier
Björn M. Stühmeier
MPMarkus R. Pietsch
Markus R. Pietsch
JSJan N. Schwämmlein
Jan N. Schwämmlein
HGHubert A. Gasteiger
Hubert A. Gasteiger
The hydrogen oxidation and evolution reaction (HOR/HER) has been widely investigated due to its importance for a broad variety of applications especially in electrolysis and fuel cells. However, owing to its extremely fast kinetics, kinetic data can only be obtained with experimental setups that provide very fast mass transport, so that the effect of hydrogen partial pressure (pH2) and kinetic limitations at high overpotentials are not yet fully understood. Here we report detailed kinetic investigations on the temperature and pressure dependence of the HOR/HER kinetics on carbon supported platinum (Pt/C) using the PEMFC-based H2-pump approach. By using ultra-low platinum loadings, we could show that the apparent activation energy of the HOR/HER on platinum increases with increasing pH2, due to a diminishing effect of the hydrogen adsorption enthalpy with increasing coverage by adsorbed hydrogen atoms on the Pt surface. Consequently, the HOR/HER reaction order with respect to pH2 also depends on the temperature. We further observed that the HOR reaches a limiting current at high HOR overpotentials that showed a direct proportionality to pH2 and a pressure-independent activation energy. We ascribe this to a limitation of the hydrogen adsorption rate either by a rate limiting Tafel-reaction or mass transport limitations.

13 January 2025 in Microscopy and Microanalysis
Verified
Journal Article
Open access
MVMaurits Vuijk
Maurits Vuijk
GDGianmarco Ducci
Gianmarco Ducci
LSLuis Sandoval
Luis Sandoval
MPMarkus Pietsch
Markus Pietsch
KRKarsten Reuter
Karsten Reuter
CSChristoph Scheurer
Christoph Scheurer
In catalysis research, the amount of microscopy data acquired when imaging dynamic processes is often too much for nonautomated quantitative analysis. Developing machine learned segmentation models is challenged by the requirement of high-quality annotated training data. We thus substitute expert-annotated data with a physics-based sequential synthetic data model. We study environmental scanning electron microscopy (ESEM) data collected from isopropanol oxidation to acetone over cobalt oxide as an example. Upon applying a temperature program during the reaction a phase transition occurs, reducing the catalyst selectivity toward acetone. This is accompanied on the micrometer ESEM scale by the formation of cracks between the pores of the catalyst surface. We aim to generate synthetic data to train a neural network capable of semantic segmentation (pixel-wise labeling) of this ESEM data. This analysis will lead to insights into this phase transition. To generate synthetic data that approximates this transition, our algorithm composes the ESEM images of the room-temperature catalyst with dynamically evolving synthetic cracks satisfying physical construction principles, gathered from qualitative knowledge accessible in the ESEM data. We mimic the surface crack growth propagation along surface paths, avoiding close vicinity to nearby pores. This physics-based approach results in a lowered rate of false positives compared to a random approach.

24 November 2025 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
MPMarkus Ruben Pietsch
Markus Ruben Pietsch
HGHubert Andreas Gasteiger
Hubert Andreas Gasteiger
One of the primary challenges still limiting the durability of proton exchange membrane fuel cells (PEMFCs) is the instability of Pt nanoparticles in Pt/C-based cathode catalysts under dynamic operating conditions. Research has shown that repeated cycling between high (> 0.85 V) and low (< 0.6 V) potentials promotes Pt dissolution, leading to particle growth via Ostwald ripening and Pt migration into the ionomer phase. This effectively reduces the electrochemically active surface area (ECSA) of the cathode catalyst, progressively impairing cell performance upon aging [1]. To evaluate catalyst stability, potential-controlled voltage-cycling accelerated stress tests (ASTs) are typically conducted in PEMFC single-cells with small active areas, which enable systematic, well-controlled parametric studies under defined conditions [2,3,4]. However, extrapolating single-cell findings to large-active area (short-)stacks is challenging, as the operation conditions often exceed those encountered in real-world applications and the added system complexity possibly introduces cell deviations in parameters like temperature, humidity, and potential, which can significantly affect degradation behavior [5,6]. In contrast, durability testing in large-active area (short-)stacks typically uses current-controlled load-cycling protocols modeled on real-world automotive drive cycles [7]. Although more representative of actual operation, these tests demand significant resources and infrastructure, and the reduced experimental control limits the applicability of sophisticated diagnostics to assess degradation mechanisms [6]. A promising intermediate solution are laboratory-scale short-stacks. They provide a cost-effective and experimentally manageable platform to investigate catalyst degradation under more realistic conditions while also enabling the application and refinement of diagnostic techniques tailored for (short-)stack-level fuel cell characterization. In this study, we present the implementation of a laboratory-scale short-stack setup for degradation testing of catalyst materials using load-cycling ASTs. To this end, a state-of-the-art commercial membrane electrode assembly (MEA), designed for heavy-duty applications, was utilized, and its degradation assessed on two distinct testing platforms. Baseline measurements were performed using potential-controlled voltage-cycling ASTs with our in-house 5 cm 2 differential-flow single-cell hardware. The data obtained from single-cell experiments were then compared to a current-controlled load-cycling AST conducted with a 25 cm 2 active area PEMFC short-stack comprising 5 cells. The load profile was selected to closely replicate the voltage profile of the single-cell tests, ensuring a meaningful comparison of the ASTs. Through intermittent characterization over the course of the ASTs, we demonstrate how dedicated current-controlled diagnostics, such as galvanostatic charging potentiometry [8] and hybrid electrochemical impedance spectroscopy [9] can be effectively employed in the short-stack setup as substitutes for conventional potentiostatic methods commonly used in single-cell testing. These methods enable the determination of MEA-specific parameters, including ECSA, hydrogen crossover, membrane shorting currents, and proton conduction resistance in the cathode catalyst layer. Overall, this study highlights how laboratory-scale short-stack setups can be employed for degradation testing of MEAs using load-cycling protocols in comparison to single-cell voltage-cycling tests, while maintaining the diagnostic capabilities of traditional potential-controlled techniques through the application of specialized current-controlled diagnostics. References: [1] P. J. Ferreira, G. J. la O', Y. Shao-Horn, D. Morgan, R. Makharia, S. Kocha, H. A. Gasteiger. J. Electrochem. Soc. 152 (11), A2256 (2005). [2] P. Zihrul, I. Hartung, S. Kirsch, G. Huebner, F. Hasché, H. A. Gasteiger. J. Electrochem Soc. 163 (6), F492-F498 (2016). [3] G. S. Harzer, J. N. Schwämmlein, A. M. Damjanović, S. Ghosh, H. A. Gasteiger. J. Electrochem. Soc. 165 (6), F3118-F3131 (2018). [4] R. K. F. Della Bella, B. M. Stühmeier, H. A. Gasteiger. J. Electrochem. Soc. 169 , 044528 (2022). [5] M. Miller, A. Bazylak. J. Power Sources . 196 (2), 601-613 (2011). [6] M. Schüttoff, C. Wachtel, R. Schlumerberger, F. Wilhelm, J. Scholta, M. Hölzle. Fuel Cells. 24 , e202300263 (2024). [7] H. L. Nguyen, J. Han, X. L. Nguyen, S. Yu, Y.-M. Goo, D. D. Le. Energies. 14 (13), 4048 (2021). [8] P. Pei, Z. Wu, Y. Li, X. Jia, D. Chen, S. Huang. Appl. Energy . 215 , 338-347 (2018). [9] P.T. Wojcik, P. Agarwal, M.E. Orazem. Electrochim. Acta . 41 (7), 977-983 (1996). Acknowledgement: We gratefully acknowledge funding from the German Federal Ministry for Digital and Transport (BMDV) under the funding scheme H2Sky (funding code 03B10706). Figure 1: Comparison of the loss of ECSA (normalized to the value at beginning-of-test) over the course of a load-cycling AST performed with a laboratory-scale short-stack versus voltage-cycling ASTs performed with single-cells. Figure 1

23 January 2026 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
YLYan-Sheng Li
Yan-Sheng Li
LALeonardo I. Astudillo
Leonardo I. Astudillo
MPMarkus R. Pietsch
Markus R. Pietsch
ADAna Marija Damjanović
Ana Marija Damjanović
HGHubert A. Gasteiger
Hubert A. Gasteiger
Unlike in the case of single-cell proton exchange membrane fuel cells (PEMFCs), implementing voltage-controlled in situ diagnostics in PEMFC stack tests is challenging, as the single cell voltage cannot be controlled precisely. Consequently, in PEMFC stacks, current-controlled methods must be used. Here we evaluate the so-called charging current (CC) diagnostics for its suitability to quantify the electrochemically active surface area (ECSA) of a platinum-catalyzed electrode of a membrane electrode assembly (MEA) as well as the H 2 -crossover ( i H 2 − x , memb ) and the ohmic-shorting currents ( i short , memb ) of MEAs. As the here proposed analysis method enables an independent quantification of both i H 2 − x , memb and i short , memb , reliable ECSA values can be obtained not only for pristine MEAs but also for severely aged MEAs that exhibit low electrode roughness factors ( rf ) and significant H 2 -crossover and shorting currents. This is validated using model MEAs with very low rf values and/or high H 2 -crossover/shorting currents, characteristic for MEAs after accelerated stress tests (ASTs). The CC diagnostics was also applied to an automotive-scale short-stack (manufactured and tested at EKPO Fuel Cell Technologies) after ∼8000 h of a load-cycling AST. Finally, a brief guideline on how to conduct the CC diagnostics and its limitations for PEMFC stacks is presented.

16 May 2024 in ChemRxiv
Verified
Preprint
Open access
PDF file
MVMaurits Vuijk
Maurits Vuijk
GDGianmarco Ducci
Gianmarco Ducci
LSLuis E. Sandoval-Diaz
Luis E. Sandoval-Diaz
MPMarkus Pietsch
Markus Pietsch
KRKarsten Reuter
Karsten Reuter
CSChristoph Scheurer
Christoph Scheurer
In catalysis research, the amount of microscopy data acquired when imaging dynamic processes is often too much for non-automated quantitative analysis. Developing machine learned segmentation models is challenged by the requirement of high-quality annotated training data. We thus substitute expert-annotated data with a physics-based sequential synthetic data model. We study environmental SEM (ESEM) data collected from isopropanol oxidation to acetone over cobalt oxide. Upon applying a temperature program during the reaction a phase transition occurs, reducing the catalyst selectivity towards acetone. This is accompanied on the μm ESEM by the formation of cracks between the pores of the catalyst surface. We aim to generate synthetic data to train a neural network capable of semantic segmentation (pixel-wise labelling) of this ESEM data. This analysis will lead to insights into this phase transition. To generate synthetic data that approximates this transition, our algorithm composes the ESEM images of the room-temperature catalyst with dynamically evolving synthetic cracks satisfying physical construction principles, gathered from qualitative knowledge accessible in the ESEM data. We mimic the surface crack growth propagation along surface paths, avoiding close vicinity to nearby pores. This physics-based approach results in a lowered rate of false positives compared to a random approach.

24 November 2025 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
CHCarla Sophie Harzer
Carla Sophie Harzer
MPMarkus Ruben Pietsch
Markus Ruben Pietsch
EBElias Bindl
Elias Bindl
HGHubert Andreas Gasteiger
Hubert Andreas Gasteiger
Proton exchange membrane (PEM) fuel cell durability targets have been raised significantly, as applications move from light-duty vehicles to heavy-duty vehicles, trucks, and airplanes. Along with lifetime targets, efficiency requirements are becoming more critical, as improving the efficiency of the fuel cell stack and system can substantially reduce operating costs. 1 A potential solution to both extend lifetime and enhance operational efficiency is by increasing the cathode Pt loading, which is a feasible option for highly demanding applications like airplanes. A recent study has shown that increased cathode Pt loadings improve the electrode durability, particularly in voltage cycling ASTs. 2 This is because the performance and degradation of the PEM fuel cell is primarily driven by the cathode roughness factor ( rf ) rather than the electrochemically active surface area ( ECSA ). 3 Additionally, higher Pt loadings enhance the oxygen reduction reaction kinetics, and simultaneously reduce the local oxygen transport resistance induced overpotentials. As a result, the fuel cell can operate at lower current densities while maintaining the same power output, leading to an improved efficiency and an extended lifespan. 4-6 Increasing the cathode Pt loading can be achieved in two ways: by increasing the electrode thickness with the same catalyst material, or by using a higher Pt loaded catalyst (i.e., a higher Pt content of carbon-supported catalysts), which enables greater electrode loadings while maintaining a constant electrode thickness. This study focuses on the impact of electrode Pt-loading and the resulting cathode thickness on the oxygen mass transport resistance determined by limiting current measurements. 7 Specifically, we investigate different Pt loaded membrane electrode assemblies (MEAs) made with catalysts ranging from 10 to 60 wt% Pt on a low-surface area carbon support, with electrode thicknesses varying between 2 µm and 17 µm. Here, we are able to correlate the total oxygen mass transport resistance to the cathode roughness factor, which is a measure of the available Pt surface area in the cathode catalyst layer independent of the cathode Pt loading and its thickness. Additionally, we examine the effect of cathode Pt loadings on the oxygen reduction reaction kinetics over a wide range of cathode Pt loadings (~ 0.01 – 0.69 mg Pt /cm 2 ). This investigation provides important insights into the determination of mass activity through Tafel analysis in dependence on the resulting electrode potential at which it is measured and determined. References: D. A. Cullen, K. C. Neyerlin, R. K. Ahluwalia, R. Mukundan, K. L. More, R. L. Borup, A. Z. Weber, D. J. Myers, and A. Kusoglu, Nature Energy , 6 , 462 (2021). C. S. Harzer, R. K. F. Della Bella, and H. A. Gasteiger, ECS Meeting Abstracts , MA2023-02 , 1775 (2023). R. K. F. Della Bella, B. M. Stühmeier, and H. A. Gasteiger, Journal of The Electrochemical Society , 169 , 044528 (2022). H. A. Gasteiger, J. E. Panels, and S. G. Yan, Journal of Power Sources , 127 , 162 (2004). T. A. Greszler, D. Caulk, and P. Sinha, Journal of The Electrochemical Society , 159 , F831 (2012). J. P. Owejan, J. E. Owejan, and W. Gu, Journal of The Electrochemical Society , 160 , F824 (2013). D. R. Baker, D. A. Caulk, K. C. Neyerlin, and M. W. Murphy, Journal of The Electrochemical Society , 156 , B991 (2009). Acknowledgement: C. Harzer, M. Pietsch, and E. Bindl gratefully acknowledge funding from the German Federal Ministry for Digital and Transport (BMDV) under the funding scheme H2Sky (funding code 03B10706).