Leonardo Isaias Astudillo

Leonardo Isaias Astudillo

Auto-generated profile, based on publicly available information

Leonardo Isaias Astudillo

Technical University of Munich

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2023 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
LALeonardo I. Astudillo
Leonardo I. Astudillo
HGHubert A. Gasteiger
Hubert A. Gasteiger
A major degradation mechanism of polymer electrolyte membrane fuel cells (PEMFCs) in transportation applications is the loss of the electrochemically active surface area (ECSA) of platinum cathode catalysts upon dynamic load cycling (resulting in cathode potential cycles). This is commonly investigated by accelerated stress tests (ASTs), cycling the cell voltage under H2/N2 (anode/cathode). Here we examine the degradation of membrane electrode assemblies with Vulcan carbon supported Pt catalysts over extended square-wave voltage cycles between 0.6-1.0 VRHE at 80 °C and 30%-100% RH under either H2/N2 or H2/Air; for the latter case, differential reactant flows were used, and the lower potential limit is controlled to correspond to the high-frequency resistance corrected cell voltage, assuring comparable aging conditions. Over the course of the ASTs, changes of the ECSA, the hydrogen crossover current, the proton conduction resistance and the oxygen transport resistance of the cathode electrode, as well as the differential-flow H2/O2 and H2/Air performance at 80 °C/100% RH were monitored. While the ECSA loss decreases with decreasing RH, it is independent of the gas feeds. Furthermore, the H2/Air performance loss only depends on the ECSA loss. ASTs under H2/N2 versus H2/Air only differ with regards to the chemical/mechanical degradation of the membrane.

23 January 2026 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
YLYan-Sheng Li
Yan-Sheng Li
LALeonardo I. Astudillo
Leonardo I. Astudillo
MPMarkus R. Pietsch
Markus R. Pietsch
ADAna Marija Damjanović
Ana Marija Damjanović
HGHubert A. Gasteiger
Hubert A. Gasteiger
Unlike in the case of single-cell proton exchange membrane fuel cells (PEMFCs), implementing voltage-controlled in situ diagnostics in PEMFC stack tests is challenging, as the single cell voltage cannot be controlled precisely. Consequently, in PEMFC stacks, current-controlled methods must be used. Here we evaluate the so-called charging current (CC) diagnostics for its suitability to quantify the electrochemically active surface area (ECSA) of a platinum-catalyzed electrode of a membrane electrode assembly (MEA) as well as the H 2 -crossover ( i H 2 − x , memb ) and the ohmic-shorting currents ( i short , memb ) of MEAs. As the here proposed analysis method enables an independent quantification of both i H 2 − x , memb and i short , memb , reliable ECSA values can be obtained not only for pristine MEAs but also for severely aged MEAs that exhibit low electrode roughness factors ( rf ) and significant H 2 -crossover and shorting currents. This is validated using model MEAs with very low rf values and/or high H 2 -crossover/shorting currents, characteristic for MEAs after accelerated stress tests (ASTs). The CC diagnostics was also applied to an automotive-scale short-stack (manufactured and tested at EKPO Fuel Cell Technologies) after ∼8000 h of a load-cycling AST. Finally, a brief guideline on how to conduct the CC diagnostics and its limitations for PEMFC stacks is presented.

9 September 2026 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
LALeonardo I. Astudillo
Leonardo I. Astudillo
HGHubert A. Gasteiger
Hubert A. Gasteiger
MTMohammad Fathi Tovini
Mohammad Fathi Tovini
IrO 2 is widely used as an anode co–catalyst in proton exchange membrane fuel cells (PEMFCs) to mitigate cell reversal (CR) induced damages. In this study, two types of IrO 2 anode co–catalysts with different reduction resistances in H 2 atmosphere are implemented into membrane electrode assemblies (MEAs) and subjected to accelerated stress tests (ASTs), combining start–up/shut–down (SUSD) and CR cycles within two protocols. Protocol 1 starts with a segment of SUSD cycles followed by a segment of CR cycles, while Protocol 2 combines SUSD and CR cycles within the same segments. Although Protocol 1 helps to isolate the performance losses induced by SUSD and CR cycles, Protocol 2 introduces a more realistic testing scenario and captures the complex interplay of concurrent degradation mechanisms. The results of Protocol 2 show that the detrimental impact of iridium dissolution from the reducible anode co–catalyst outweighs the benefit of its higher OER activity at the early stages of the AST, while the advantage of its higher OER activity becomes apparent in the later stages of the AST. This study shows that OER activity and reduction resistance are critical for benchmarking anode OER co–catalysts, with the optimal balance dictated by system–specific operating conditions.

1 September 2019 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
LALeonardo Isaias Astudillo
Leonardo Isaias Astudillo
HGHubert A. Gasteiger
Hubert A. Gasteiger
Polymer-electrolyte-membrane fuel cells (PEMFCs) have proven their applicability as a clean energy conversion technology. At the same time, a clear understanding of their degradation under dynamic operation is critical to project and ultimately improve long-term durability. In order to mimic real-life operation stressors, accelerated stress tests (ASTs) are used to enhance a particular type of degradation mechanism. After the AST application, various physico- and electrochemical diagnostic tools aid to understand and catalogue the observed performance losses. Since the ultimate goal is to develop in situ mitigation and recovery strategies for automotive applications, a comprehensive voltage loss study describing the degradation effects on performance losses is desired. Particularly inside ASTs, voltage cycling tests reproduce conditions that mimic the dynamic operation of a fuel cell stack, and which are directly linked to the degradation of catalyst layers1 in a membrane electrode assembly (MEA). In a semi-empirical study, voltage cycling tests were applied by Kneer et al. 2 to promote electrochemical surface area (ECSA) losses of a carbon-supported platinum catalyst (Pt/C) for the oxygen reduction reaction (-ORR), establishing an ECSA loss semiempirical model for a wide range of voltage cycling conditions. Subsequently, this model was used to project performance losses in H2/air curves based on a theoretical relationship between ECSA evolution and the ORR observed kinetic and transport losses. However, the authors observed that their model prediction resulted in a substantial unaccounted voltage loss (compared to experimental data), suggesting that deeper analyses are required to understand voltage cycling induced performance losses, with the ultimate goal to develop in situ mitigation and recovery strategies. Therefore, our study will make use of voltage cycling ASTs, which will correlate voltage losses to degradation phenomena measured by various diagnostic tests3. These include the ORR mass activity (via H2/O2 measurements), proton transport resistance through the membrane and catalyst layer (via impedance analyses), and O2 transport resistance (via limiting current measurements). By performing a standardized protocol, the differences in MEA aging during voltage cycling tests conducted with H2/air vs. the more frequently used H2/N2 (anode and cathode, respectively) will be separately studied. Furthermore, as observed in Figure 1a, lowering the relative humidity (RH) of the reactants significantly reduces ECSA losses during voltage cycling tests, in comparison to the same protocol performed at 100% RH. More importantly, the H2/air performance losses are substantially lowered after low RH testing (in comparison to 100% RH) (Figure 1b). The unaccounted voltage losses vs. specific current density (ispec ) (the difference between the theoretical 70 mV/dec. line (black line in Figure 1c) and the corrected experimental cell voltages) are lowered, as well. Therefore, the effect of further operational stressors (e.g. cell temperature) on voltage cycling aging for H2/N2 vs. H2/air will be presented. Ultimately, we will seek to correlate the observed losses to those under automotive operating conditions. This insight leads to a better understanding of catalyst degradation and its subsequent suppression via appropriate mitigation strategies through the correct application of operating conditions as described by single cell experiments. Figure 1: a) ECSA losses vs. number of cycles. The insert depicts the used voltage profile (1 cycle equals to 8s at the lower voltage limit (LVL) followed by 8s at the higher voltage limit (HVL), voltage ramp >4V/s). Voltage cycling tests were performed as described by Harzer et. al. in a single-cell PEMFC with 5 cm2 active area (loading: 0.1 and 0.4 mgPt cm-2 in the anode and cathode, respectively; 100 kPaabs, 80°C and H2/N2 flows of 200 nccm/75 nccm on anode/cathode, respectively)3. b) H2/air performance curves (conditions: differential flow, 80°C, 170 kPaabs inlet-controlled pressure, anode: 2000 nccm of H2, cathode: 5000 nccm of air). c) Tafel representation of I-V curves after voltage cycling AST at 30% RH (20k cycles) and 100% RH (10k cycles). Ecell was corrected for HFR, H+ resistance through the catalyst layer, and O2 mass transport resistance; specific current density (ispec ) is corrected for cell shorting resistance and H2 crossover current. References Kneer, A.; Wagner, N.; Sadeler, C.; Scherzer, A. C.; Gerteisen, D., Effect of Dwell Time and Scan Rate during Voltage Cycling on Catalyst Degradation in PEM Fuel Cells. J Electrochem Soc 2018, 165 (10), F805-F812. Kneer, A.; Wagner, N., A Semi-Empirical Catalyst Degradation Model Based on Voltage Cycling under Automotive Operating Conditions in PEM Fuel Cells. J Electrochem Soc 2019, 166 (2), F120-F127. Harzer, G. S.; Schwämmlein, J. N.; Damjanovic, A. M.; Ghosh, S.; Gasteiger, H. A., Cathode Loading Impact on Voltage Cycling Induced PEMFC Degradation: A Voltage Loss Analysis. J Electrochem Soc 2018, 165 (6), F3118-F3131. Figure 1