Ayoade Felix Agbetuyi

Ayoade Felix Agbetuyi

Auto-generated profile, based on publicly available information

Ayoade Felix Agbetuyi

Department of Electrical & Information Engineering, Covenant University, Ota, Nigeria

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2019 in Heliyon
Verified
Journal Article
Open access
AEAyodele Benjamin Esan
Ayodele Benjamin Esan
AAAyoade Felix Agbetuyi
Ayoade Felix Agbetuyi
OOOghenevogaga Oghorada
Oghenevogaga Oghorada
KOKingsley Ogbeide
Kingsley Ogbeide
AAAyokunle Awelewa
Ayokunle Awelewa
AAA. Esan Afolabi
A. Esan Afolabi
This paper presents the use of a novel approach in assessing the generation reliability of a hybrid mini-grid system (HMS) based on the optimal design result obtained from the HOMER software. A typical Nigerian rural community - Lade II in Kwara State was used as a case study where the energy demand for the residential and commercial loads was 2.5MWh/day and 171kWh/day respectively. The optimized HMS results from HOMER comprising of a solar photovoltaic (PV) array (1.5MW), diesel generators (350kW) and battery storage (1200 units) has a combined least net present cost of $4,909,206 and a levelized electricity tariff of $0.396 per kWh. Contrasting the HMS with a diesel-only system for the community, an approximate 97% reduction in all pollutant emissions was observed. Furthermore, fluctuations in diesel fuel prices, variations in average solar insolation, and variations in the solar PV's capital/replacement costs were utilized in conducting a sensitivity analysis for the HMS. The capacity outage probability table (COPT) was utilized in validating the reliability of the simulation results obtained from HOMER. The HMS was observed to experience a load loss of 0.769MW, 0.594MW & 0.419MW when zero, one and two diesel generator(s) respectively were operational for all of the Solar PV's and Batteries being off-line. The loss of load probability (LOLP), loss of load expectation (LOLE), and total expected load loss (ELL) obtained from the COPT were 5.76 × 10-8, 5.0457 × 10-4 hr/yr and 0.025344Watt respectively. The results show the reliability of the HMS and also depicts a highly economical and feasible hybrid energy system.

10 September 2018 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
KOKayode Oladipo
Kayode Oladipo
AFAgbetuyi A. Felix
Agbetuyi A. Felix
OBOwolabi Bango
Owolabi Bango
OCObiakor Chukwuemeka
Obiakor Chukwuemeka
FOFagbuaro Olawale
Fagbuaro Olawale

1 January 2018 in Cogent Engineering
Verified
Journal Article
Open access
AAAdeyinka Ajao Adewale
Adeyinka Ajao Adewale
AAAderibigbe Adekitan
Aderibigbe Adekitan
OIOfukowoicho Jeremiah Idoko
Ofukowoicho Jeremiah Idoko
FAFelix Ayoade Agbetuyi
Felix Ayoade Agbetuyi
ISIsaac Adekunle Samuel
Isaac Adekunle Samuel
Energy is indispensable to human existence, and its need is on the increase daily due to technological advancement. In recent times, there is sporadic increase in the development of modern buildings, and these buildings require a cost-effective and sustainable source of energy. Nigeria and some other African countries have major energy shortage issues due to the insufficient power generation and distribution facilities. This energy poverty creates a challenge for the growing population, and as such, it is vital to ensure that the energy supplied to a building is duly optimized and delivered cost effectively. In this study, an energy audit of an eight-floor multipurpose business complex was performed to determine the nature and type of loads within the building. Based on the load profile and energy consumption over a 10-year period, three alternative energy sources (national grid, diesel generator and photovoltaic [PV] system) were considered using various load-sharing ratios. The result reveals that though PV solar system is a renewable energy source that reduces the production of greenhouse gases generated by burning diesel, its continuous application in low–middle-income country like Nigeria may be challenged by the initial start-up capital which raises the cost of its unit energy.

1 June 2018
Verified
Conference Paper
Closed access
AFAgbetuyi Ayoade Felix
Agbetuyi Ayoade Felix
OHOrovwode Hope
Orovwode Hope
OJOlowoleni Joseph
Olowoleni Joseph
NCNwangwu Chukwuebuka
Nwangwu Chukwuebuka
One of the challenges of unsatisfactory performance of solar powered equipment in Nigeria is the importation of substandard solar panels which in turns give rise to improper rating of the solar panels. Some of the equipment manufacturers are known for labeling the solar panels with arbitrary ratings in other to sell and make profit. Since the solar powered equipment depends on the Sun for its energy, there is need to monitor and measure the solar panel parameters like voltage, current, light intensity and temperature. This is necessary to confirm if the solar panel is performing to expectation and giving good readings. This work aims at developing a Solar Energy Measurement System that will aid in the measurement and monitoring of solar panel parameters like voltage, current, light intensity and temperature. The design work is divided into two main parts, hardware and software sections. The hardware involves the development of major units like the power supply unit, the control unit and the sensor units of the entire project by using solid state electronic components, integrated circuits and microcontroller. The software design involves the development of a program using C programming language to enable the arduino microcontroller to function and perform as desired. The basic inputs to the system are the sensor units. They sense the required variable that is to be measured and the measured values are then displayed. The results obtained from the display unit are then compared with the manufacturer's values that are found on the solar panel. It is observed that there are slight differences between the measured and the manufacturer's values, but still within a tolerable range (less than 5%).

10 September 2018 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
AAAyoade Felix Agbetuyi
Ayoade Felix Agbetuyi
EUEyo Okon Udeme
Eyo Okon Udeme
EOEmeka Obiakor
Emeka Obiakor
OKOladipupo O Kayode
Oladipupo O Kayode
BOBango Owolabi
Bango Owolabi
The problem of Renewable Dispersed Generation (RDG) and renewable resource harnessing in most cases, is not the inadequacy of resource distribution at a particular location but rather, it is the perpetually deprived exploitation of these resources. The existing dread for the performance of distributed generation systems that utilize renewable sources for power generation has crippled sustainable power generation expansion for several years. Hence, this study performs a practical assessment of the productivity of solar PV systems in Nigeria. In this study, five states with diverse geographical or meteorological data are selected from the cardinal regions of the country. These include Sokoto State (North West), Borno State (North East), Ogun State (South West), Rivers State (South South) and Abuja, the federal capital territory at the center. The global horizontal radiations available from the National Aviation and Space Agency (NASA) for these cities were used in simulating the performance of a 1-MW grid-tied solar PV plant using the PVsyst software. The result shows that the performance parameters with respect to energy production are better in the northern region compared with the southern region with capacity factors decreasing from 20.46% to 16.21% for a 1 MW solar PV plant located at these regions. This was seen to reflect on the corresponding annual energy yield of similar systems sited at these locations. Also, the performance ratios of these systems, given their respective reference yields, were observed to be better in the southern region compared with the northern region of Nigeria. This can be attributed to external factors that can influence system efficiency. These factors tend to favor systems located at the southern region as opposed to those at the northern region. These findings validate this study as a decision tool for predicting the performance of any Renewable Dispersed Generation (RDG) systems utilizing solar energy as the source at other regions of the country.

4 March 2021 in Journal of Engineering
Verified
Journal Article
Open access
PDF file
HOHope Orovwode
Hope Orovwode
SMSimeon Matthew
Simeon Matthew
AAA. Felix Agbetuyi
A. Felix Agbetuyi
UAU. Anthony Adoghe
U. Anthony Adoghe
EAElizabeth Oses Amuta
Elizabeth Oses Amuta
Frequent burning of three-phase induction motors windings has been reported. The initial symptoms observed before the burning of the windings were an increase in operating current and a temperature rise. The induction motor protection and control system was designed, developed, and constructed to reduce the problem of burnt winding by early detection and disconnection of supply if the problem persists. It was found to be efficient, reliable, durable, and rugged. The system is a boost to Nigerian industrialists as it will reduce cases of burning of induction motors and the consequent downtime and cost. The system is cheap and easy to repair and maintain because the parts and components used in the design are available locally.