This paper presents the use of a novel approach in assessing the generation reliability of a hybrid mini-grid system (HMS) based on the optimal design result obtained from the HOMER software. A typical Nigerian rural community - Lade II in Kwara State was used as a case study where the energy demand for the residential and commercial loads was 2.5MWh/day and 171kWh/day respectively. The optimized HMS results from HOMER comprising of a solar photovoltaic (PV) array (1.5MW), diesel generators (350kW) and battery storage (1200 units) has a combined least net present cost of $4,909,206 and a levelized electricity tariff of $0.396 per kWh. Contrasting the HMS with a diesel-only system for the community, an approximate 97% reduction in all pollutant emissions was observed. Furthermore, fluctuations in diesel fuel prices, variations in average solar insolation, and variations in the solar PV's capital/replacement costs were utilized in conducting a sensitivity analysis for the HMS. The capacity outage probability table (COPT) was utilized in validating the reliability of the simulation results obtained from HOMER. The HMS was observed to experience a load loss of 0.769MW, 0.594MW & 0.419MW when zero, one and two diesel generator(s) respectively were operational for all of the Solar PV's and Batteries being off-line. The loss of load probability (LOLP), loss of load expectation (LOLE), and total expected load loss (ELL) obtained from the COPT were 5.76 × 10-8, 5.0457 × 10-4 hr/yr and 0.025344Watt respectively. The results show the reliability of the HMS and also depicts a highly economical and feasible hybrid energy system.
1 October 2019 in Sustainable Energy Technologies and Assessments
This paper presents a novel inter-cluster direct current (DC) capacitor voltage balancing control scheme for the single-star configured modular multilevel cascaded converter (MMCC)-based static synchronous compensator (STATCOM) under unbalanced grid voltage. The negative-sequence component of grid voltage at the point of common connection (PCC) causes unbalanced active power flow in the phase limbs of converter. This leads to the imbalance of DC voltages of the submodule capacitors across the MMCC phases, and consequently, the malfunction of converter. The proposed solution is to inject both negative-sequence current (NSC) and zero-sequence voltage (ZSV) into the phase limbs of MMCC. A quantification factor Q F is used to achieve the sharing of intercluster active power between the NSC and ZSV injection methods. Accurate determination of the quantification factor has been presented. In addition to maintaining the DC voltages of sub-module capacitor across the MMCC phases balanced, it also prevents the overcurrent and overvoltage of converter by injecting NSC and ZSV with the right proportion. The control scheme is validated on a 3.54 kV 1.2 MVA power system using MMCC-based STAT-COM with 3-level bridge cells as sub-modules. The results show that the proposed scheme provides superior effectiveness in eliminating the voltage imbalance of DC capacitor in the phase limb while maintaining low voltage and current ratings.
Generally, sub-Saharan countries possess abundant energy resources including renewables and fossil sources, with natural gas potentially being among the more abundant resource second only to solar power. For conventional electrical energy generation, gas turbines are one of the most prominent technologies being adopted in producing electricity from natural gas. Nigeria, for instance has the largest natural gas reserves in Africa, and the 9th largest in the World. Thus, more than 80% of her electricity generation utilizes gas turbines. To effectively monitor the state of these gas turbines, several sensors are located on the turbines to acquire data in real time. In this data article, we present the acquired data from a 5.68-MW gas turbine installed as an independent power producing unit in a community in Ogun State, Nigeria over a period of six months. Performing various descriptive analysis on the dataset, the real power measurements were taken as the target parameters, and based on a threshold correlation co-efficient of 0.5, only sixteen (16) parameters were shown to be more closely positively correlated with the real power measurements. Thus, any variation in the real power supplied by the gas turbine would have a commensurate effect on any of the other 16 parameters identified, and could thus help in troubleshooting or scheduling maintenance.