Maria Fernanda Silva Andrade-Bortoletto

Maria Fernanda Silva Andrade-Bortoletto

Auto-generated profile, based on publicly available information

Maria Fernanda Silva Andrade-Bortoletto

Department of Oral Diagnosis, Piracicaba Dental School, University of Campinas, Piracicaba, Brazil

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 March 2024 in Clinical Oral Investigations
Verified
Journal Article
Open access
PDF file
TSThaísa Pinheiro Silva
Thaísa Pinheiro Silva
MAMaria Fernanda Silva Andrade-Bortoletto
Maria Fernanda Silva Andrade-Bortoletto
TOThaís Santos Cerqueira Ocampo
Thaís Santos Cerqueira Ocampo
CACaio Alencar-Palha
Caio Alencar-Palha
MBMichael M Bornstein
Michael M Bornstein
MOMatheus L. Oliveira
Matheus L. Oliveira
Objectives: To evaluate the performance of a commercially available Generative Pre-trained Transformer (GPT) in describing and establishing differential diagnoses for radiolucent lesions in panoramic radiographs. Materials and methods: Twenty-eight panoramic radiographs, each containing a single radiolucent lesion, were evaluated in consensus by three examiners and a commercially available ChatGPT-3.5 model. They provided descriptions regarding internal structure (radiodensity, loculation), periphery (margin type, cortication), shape, location (bone, side, region, teeth/structures), and effects on adjacent structures (effect, adjacent structure). Diagnostic impressions related to origin, behavior, and nature were also provided. The GPT program was additionally prompted to provide differential diagnoses. Keywords used by the GPT program were compared to those used by the examiners and scored as 0 (incorrect), 0.5 (partially correct), or 1 (correct). Mean score values and standard deviation were calculated for each description. Performance in establishing differential diagnoses was assessed using Rank-1, -2, and − 3. Results: Descriptions of margination, affected bone, and origin received the highest scores: 0.93, 0.93, and 0.87, respectively. Shape, region, teeth/structures, effect, affected region, and nature received considerably lower scores ranging from 0.22 to 0.50. Rank-1, -2, and − 3 demonstrated accuracy in 25%, 57.14%, and 67.85% of cases, respectively. Conclusion: The performance of the GPT program in describing and providing differential diagnoses for radiolucent lesions in panoramic radiographs is variable and at this stage limited in its use for clinical application. Clinical relevance: Understanding the potential role of GPT systems as an auxiliary tool in image interpretation is imperative to validate their clinical applicability.

7 June 2025 in Clinical Oral Implants Research
Verified
Journal Article
Open access
MAMaria Fernanda Silva da Andrade‐Bortoletto
Maria Fernanda Silva da Andrade‐Bortoletto
TJThanatchaporn Jindanil
Thanatchaporn Jindanil
RFRocharles Cavalcante Fontenele
Rocharles Cavalcante Fontenele
RJReinhilde Jacobs
Reinhilde Jacobs
DFDeborah Queiroz Freitas
Deborah Queiroz Freitas
Objective: Identification of the mandibular incisive canal (MIC) prior to anterior implant placement is often challenging. The present study aimed to validate an enhanced artificial intelligence (AI)‐driven model dedicated to automated segmentation of MIC on cone beam computed tomography (CBCT) scans and to compare its accuracy and time efficiency with simultaneous segmentation of both mandibular canal (MC) and MIC by either human experts or a previously trained AI model.Materials and Methods: An enhanced AI model was developed based on 100 CBCT scans using expert‐optimized MIC segmentation within the Virtual Patient Creator platform. The performance of the enhanced AI model was tested against human experts and a previously trained AI model using another 40 CBCT scans. Performance metrics included intersection over union (IoU), dice similarity coefficient (DSC), recall, precision, accuracy, and root mean square error (RSME). Time efficiency was also evaluated.Results: The enhanced AI model had IoU of 93%, DSC of 93%, recall of 94%, precision of 93%, accuracy of 99%, and RMSE of 0.23 mm. These values were significantly higher than those of the previously trained AI model for all metrics, and for manual segmentation for IoU, DSC, recall, and accuracy (p < 0.0001). The enhanced AI model demonstrated significant time efficiency, completing segmentation in 17.6 s (125 times faster than manual segmentation) (p < 0.0001).Conclusion: The enhanced AI model proved to allow a unique and accurate automated MIC segmentation with high accuracy and time efficiency. Besides, its performance was superior to human expert segmentation and a previously trained AI model segmentation.

27 July 2024 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
JFJuliana Batista Melo da Fonte
Juliana Batista Melo da Fonte
RFRocharles Cavalcante Fontenele
Rocharles Cavalcante Fontenele
AGAmanda Farias Gomes
Amanda Farias Gomes
DRDébora Costa Ruiz
Débora Costa Ruiz
MAMaria Fernanda Silva Andrade‐Bortoletto
Maria Fernanda Silva Andrade‐Bortoletto
DFDeborah Queiroz Freitas
Deborah Queiroz Freitas

25 October 2025 in Journal of Dentistry
Verified
Journal Article
Open access
MAMaria Fernanda Silva Andrade-Bortoletto
Maria Fernanda Silva Andrade-Bortoletto
XDXijin Du
Xijin Du
EDEslam Abdelwahab Dawood
Eslam Abdelwahab Dawood
OVOana Elena Burlacu Vatamanu
Oana Elena Burlacu Vatamanu
MTMihai Tarce
Mihai Tarce
RJReinhilde Jacobs
Reinhilde Jacobs
This scoping review aims to evaluate the extent of artificial intelligence (AI)- driven automation currently available for designing static surgical guides (SG) for implant placement and its correlation with implant placement accuracy. A comprehensive literature search was conducted across PubMed, Scopus, Web of Science, Embase, Cochrane Library, and grey literature up to February 2025. Two reviewers independently screened 518 English-language articles, selecting 140 for eligibility evaluation. After applying exclusion criteria, seven studies were included for full-text review. The SG planning process was classified as manual, semi-automated, or fully automated driven by AI. Implant placement accuracy was assessed based on linear (cervical and apical) and angular deviations, with a detailed review of measurement methods used. Additionally, a market survey was conducted to identify available SG design software, its key features, and the level of automation implemented for each design step. All included studies (n=7) employed a semi-automated software for SG design. The mean deviations in implant placement using SGs were 0.65 mm (0.22 to 1.19 mm) (linear-cervical), 0.95 mm (0.18 to 2.11 mm) (linear-apical), and 2.92° (0.77 to 6.35°) (angular). The software programs used were: coDiagnostiX™ software (Version 9.0, Dental Wings GmbH, Germany), Smop-software (version 2.7.0, Swissmeda AG, Switzerland), 3Shape Implant studio (Version 2021.1.2, 3Shape, Denmark), R2WARE™ (MegaGen implant, Korea), 3-Matic modelling software (Materialise, Belgium) and Blue Sky Plan 4.8 (Blue Sky Bio, USA). This scoping review found that most surgical guide planning software employs a semi-automated approach requiring human intervention, which has shown clinically acceptable implant placement accuracy. Fully automated (AI-based) designs were not yet validated scientifically.

7 August 2023 in Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
Verified
Journal Article
Closed access
MAMaria Fernanda Silva Andrade-Bortoletto
Maria Fernanda Silva Andrade-Bortoletto
RFRocharles Cavalcante Fontenele
Rocharles Cavalcante Fontenele
AFAmanda Farias-Gomes
Amanda Farias-Gomes
DFDeborah Queiroz Freitas
Deborah Queiroz Freitas

7 November 2024 in Clinical Oral Investigations
Verified
Journal Article
Closed access
PDF file
DRDébora Costa Ruiz
Débora Costa Ruiz
MAMaria Fernanda Silva Andrade-Bortoletto
Maria Fernanda Silva Andrade-Bortoletto
CCCamila Porto Capel
Camila Porto Capel
CTCamila Tirapelli
Camila Tirapelli
HGHugo Gaêta-Araujo
Hugo Gaêta-Araujo
DFDeborah Queiroz Freitas
Deborah Queiroz Freitas