Eslam Abdelwahab Dawood

Eslam Abdelwahab Dawood

Auto-generated profile, based on publicly available information

Eslam Abdelwahab Dawood

OMFS‐IMPATH Research Group, Department of Imaging and Pathology Faculty of Medicine, KU Leuven Leuven Belgium

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2025 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Open access
BEBahaaeldeen M. Elgarba
Bahaaeldeen M. Elgarba
RFRocharles Cavalcante Fontenele
Rocharles Cavalcante Fontenele
EDEslam Abdelwahab Dawood
Eslam Abdelwahab Dawood
PLPierre Lahoud
Pierre Lahoud
JMJan Meeus
Jan Meeus
RJReinhilde Jacobs
Reinhilde Jacobs
Objectives: To assess the clinical validity of artificial intelligence (AI)‐driven virtual implant placement compared to human intelligence (HI)‐based virtual and actual single implant placement in the posterior mandible. Material and Methods: Thirty‐two patients for whom experts performed single implant placement in the posterior mandible were included, each with preoperative and postoperative cone‐beam computed tomography (CBCT) scans. The preoperative scans were registered to the corresponding postoperative scans and used for both AI‐ and HI‐driven virtual implant planning at the implant site. From each case, three implants' scenarios (i.e., HI‐placed, AI‐planned, and HI‐planned) were exported and compared. The analysis focused on angular deviation and the spatial relationship of each implant to adjacent anatomical structures and the expert‐designed prosthetic wax‐up. In addition, pairwise comparisons were performed to quantify angular and linear deviations at both the coronal and apical levels. Implant length and diameter from planned versus placed implants were evaluated, and planning time and consistency were compared between AI‐ and HI‐based approaches. Results: AI‐based planning showed no statistically significant differences compared to HI‐based methods observed in angular deviation relative to adjacent tooth (HI‐placed: 7.7° ± 5.6°, AI: 6° ± 4.7°, HI‐planned: 5.2° ± 5.7°) and coronal deviation (AI vs. HI‐placed: 0.9 ± 0.8 mm, AI vs. HI‐planned: 0.8 ± 0.4 mm, HI‐planned vs. HI‐placed: 1.0 ± 1.1 mm), all with p > 0.05. Implant diameter and length were also consistent across the different approaches, with HI‐placed (4.3 ± 0.3 mm; 9.7 ± 1.3 mm), AI (4.3 ± 0.4 mm; 9.9 ± 1.2 mm), and HI‐planned (4.3 ± 0.4 mm; 9.8 ± 1.3 mm) showing no significant differences ( p > 0.05). However, AI planning was significantly faster (36.3 ± 7.3 s vs. 373 ± 113 s) and more consistent, with a median surface deviation of 0 mm compared to 0.39 mm for HI ( p < 0.05). Conclusion: The AI tool showed clinically valid implant selection, matched expert placement and planning in virtual implant positioning for missing mandibular premolars and molars while being highly consistent and 10 times faster compared to human expert planning.

14 March 2026 in Journal of Dentistry
Verified
Journal Article
Open access
EDEslam Abdelwahab Dawood
Eslam Abdelwahab Dawood
RARand Abumaylih
Rand Abumaylih
BEBahaaeldeen M. Elgarba
Bahaaeldeen M. Elgarba
RFRocharles Cavalcante Fontenele
Rocharles Cavalcante Fontenele
RJReinhilde Jacobs
Reinhilde Jacobs
To map current evidence on artificial intelligence (AI)-enhanced robotic systems for dental implant placement, focusing on system autonomy, accuracy, and clinical applicability. This mixed-method scoping review followed PRISMA-ScR guidelines and included studies published up to August 2025. Five electronic databases were systematically searched (PubMed, Scopus, Web of Science, Embase, Cochrane Library), supplemented by grey literature search, to identify English-language studies assessing robotic-assisted dental implant placement in terms of accuracy, time efficiency, or clinical feasibility. Two reviewers independently performed study selection, data extraction, and quality appraisal. Quantitative data were pooled descriptively using random-effects models with subgroup analyses, while remaining findings were synthesized narratively. A parallel search identified commercially available robotic and dynamic navigation systems, including their regulatory status, validation level, and human-robot interaction features. The systematic search identified 27 studies evaluating robotic-assisted dental implant placement met the inclusion criteria. Methodological quality was generally high, with 92.6% of studies scoring ≥ 8/10 on the Mixed Methods Appraisal Tool (MMAT). Robotic systems demonstrated high placement accuracy, with a mean coronal deviation of 0.45 mm, apical deviation of 0.50 mm, and angular deviation of 0.80° However, statistical heterogeneity was high across outcomes (I² > 97%). Subgroup analyses indicated that fully autonomous robotic systems achieved the lowest deviation values. Implant placement in the mandible showed greater accuracy compared with maxillary and zygomatic sites. When compared with dynamic navigation systems, robotic-assisted approaches demonstrated comparable linear deviations but superior angular precision. Limited evidence suggested potential improvements in procedural efficiency, particularly in multi-implant cases. Robotic systems show strong technical performance, but current evidence is dominated by in vitro and single-center studies with limited long-term clinical data. Future multicenter trials with standardized outcomes and long-term follow-up are needed to confirm clinical benefits. Robotic systems offer high accuracy and reproducibility in dental implant placement, potentially improving efficiency and reducing variability in complex cases. However, clinical adoption should be guided by further multicenter trials with long-term outcomes.

25 October 2025 in Journal of Dentistry
Verified
Journal Article
Open access
MAMaria Fernanda Silva Andrade-Bortoletto
Maria Fernanda Silva Andrade-Bortoletto
XDXijin Du
Xijin Du
EDEslam Abdelwahab Dawood
Eslam Abdelwahab Dawood
OVOana Elena Burlacu Vatamanu
Oana Elena Burlacu Vatamanu
MTMihai Tarce
Mihai Tarce
RJReinhilde Jacobs
Reinhilde Jacobs
This scoping review aims to evaluate the extent of artificial intelligence (AI)- driven automation currently available for designing static surgical guides (SG) for implant placement and its correlation with implant placement accuracy. A comprehensive literature search was conducted across PubMed, Scopus, Web of Science, Embase, Cochrane Library, and grey literature up to February 2025. Two reviewers independently screened 518 English-language articles, selecting 140 for eligibility evaluation. After applying exclusion criteria, seven studies were included for full-text review. The SG planning process was classified as manual, semi-automated, or fully automated driven by AI. Implant placement accuracy was assessed based on linear (cervical and apical) and angular deviations, with a detailed review of measurement methods used. Additionally, a market survey was conducted to identify available SG design software, its key features, and the level of automation implemented for each design step. All included studies (n=7) employed a semi-automated software for SG design. The mean deviations in implant placement using SGs were 0.65 mm (0.22 to 1.19 mm) (linear-cervical), 0.95 mm (0.18 to 2.11 mm) (linear-apical), and 2.92° (0.77 to 6.35°) (angular). The software programs used were: coDiagnostiX™ software (Version 9.0, Dental Wings GmbH, Germany), Smop-software (version 2.7.0, Swissmeda AG, Switzerland), 3Shape Implant studio (Version 2021.1.2, 3Shape, Denmark), R2WARE™ (MegaGen implant, Korea), 3-Matic modelling software (Materialise, Belgium) and Blue Sky Plan 4.8 (Blue Sky Bio, USA). This scoping review found that most surgical guide planning software employs a semi-automated approach requiring human intervention, which has shown clinically acceptable implant placement accuracy. Fully automated (AI-based) designs were not yet validated scientifically.

16 January 2026 in Digital Dentistry Journal
Verified
Journal Article
Open access
EDEslam Abdelwahab Dawood
Eslam Abdelwahab Dawood
SAStijn Van Aelst
Stijn Van Aelst
BEBahaaeldeen M. Elgarba
Bahaaeldeen M. Elgarba
RFRocharles Cavalcante Fontenele
Rocharles Cavalcante Fontenele
RJReinhilde Jacobs
Reinhilde Jacobs

24 March 2026 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Open access
EDEslam Abdelwahab Dawood
Eslam Abdelwahab Dawood
BEBahaaeldeen M. Elgarba
Bahaaeldeen M. Elgarba
RFRocharles Cavalcante Fontenele
Rocharles Cavalcante Fontenele
RJReinhilde Jacobs
Reinhilde Jacobs
Cone beam computed tomography (CBCT) scans acquired with interocclusal separation improve stability and reduce motion artifacts but lack reliable occlusal contacts. Accurately reconstructing occlusion is critical for diagnosis, restorative planning, and implant workflows. While integrating intraoral scans (IOSs) can capture occlusion accurately, the validity of artificial intelligence (AI)-driven alignment algorithms for reconstructing occlusion in separated CBCT datasets has not been established. The purpose of this retrospective study was to validate an AI-based tool for reconstructing occlusion by aligning separated maxillary and mandibular CBCT segmentations using IOS-derived occlusal data, with IOS occlusion as the reference standard. Forty paired CBCT scans acquired with interocclusal separation and corresponding IOS datasets were uploaded into an AI-driven platform, which automatically segmented and registered the CBCT and IOS scans. The AI tool used IOS‑derived occlusal relationships to align the segmented CBCT models, generating 3 occluded models: IOS‑only, AI-fused CBCT‑IOS, and CBCT‑only. Occlusal contacts, occlusal intersections, occlusal contact surface area, and 3-dimensional (3D) occlusal surface deviations were analyzed. Statistical analyses were performed using the Friedman test, repeated-measures ANOVA, and the Mann-Whitney U test. Intra-operator reliability was assessed using weighted kappa (κ) (α=.05). No significant differences were observed between IOS and AI-fused CBCT-IOS models for occlusal contacts or contact surface area (median=46, mean ±standard deviation=256 ±170 mm²) and (median=48, mean=255 ±166 mm²), respectively. AI-driven CBCT models showed significantly fewer contacts (median=22, mean ±standard deviation=184 ±163 mm²). Median surface deviation between IOS and fused models was 0 µm, whereas CBCT-only models showed deviations of 70 to 80 µm. Dentition status did not influence outcomes. Intra-operator reliability was excellent (κ=0.86). The AI-driven fusion of IOS occlusal data with CBCT scans acquired with interocclusal separation accurately reconstructs occlusion, enabling reliable treatment planning without the need for CBCT acquisition in occlusion.

3 March 2026 in Dentomaxillofacial Radiology
Verified
Journal Article
Open access
PDF file
BEBahaaeldeen M. Elgarba
Bahaaeldeen M. Elgarba
EDEslam Abdelwahab Dawood
Eslam Abdelwahab Dawood
RFRocharles Cavalcante Fontenele
Rocharles Cavalcante Fontenele
PLPierre Lahoud
Pierre Lahoud
JMJan Meeus
Jan Meeus
RJReinhilde Jacobs
Reinhilde Jacobs
Objectives: This study evaluated a validated artificial intelligence (AI) tool for virtual implant planning by comparing its performance with expert-planned and clinically placed implants in single-tooth rehabilitation cases. Methods: Pre- and postoperative cone-beam CT (CBCT) scans were retrospectively collected from 32 single-tooth implant cases. Actual implants were placed by expert clinicians using a human intelligence (HI)-based approach guided by the preoperative CBCT. The same scans were used to generate both AI- and HI-based virtual implant plans. Pre- and postoperative scans were registered to allow accurate comparison between placed and planned implants. Three plans were evaluated per case: clinically placed implant (HI-place), HI-planned implant (HI-plan), and AI-planned implant (AI). Evaluations included angular deviation relative to adjacent teeth and prosthetic wax-ups, vertical and horizontal bone thickness, proximity to vital structures, implant dimensions, planning time, and planning repeatability. Results: The Friedman test indicated no significant differences in implant location among the 3 approaches (P > .05). Angular deviations were similar across methods for both the neighboring tooth (HI-place = 7.01 ± 4.7°; HI-plan = 7.30 ± 5.6°; AI = 6.86 ± 3.7°) and the wax-up (HI-place = 5.22 ± 3.0°; HI-plan = 4.55 ± 3.0°; AI = 5.50 ± 4.9°). Implant diameter and length selections also did not differ significantly across HI-place (4.06 ± 0.4 mm; 10.61 ± 1.4 mm), HI-plan (4.06 ± 0.4 mm; 10.45 ± 1.4 mm), and AI (4.05 ± 0.5 mm; 10.39 ± 1.4 mm). AI was significantly faster (P < .05), requiring 150 s vs 429 s for HI-plan, and showed excellent repeatability with zero deviation between repeated plans. Conclusions: AI-driven virtual implant planning achieved clinically acceptable placement comparable to expert clinicians in single-implant rehabilitation, with superior efficiency and repeatability, supporting its use in routine presurgical workflows. Advances in knowledge: Integrating AI for implant location and dimensions selection, with accuracy comparable to expert clinicians, can streamline the digital implant workflow, reduce planning time, and allow clinicians to focus on verifying the AI-generated plan prior to clinical transfer, thereby increasing the time available for the actual treatment procedure.