Saipavitra Murali-Manohar

Saipavitra Murali-Manohar

Auto-generated profile, based on publicly available information

Saipavitra Murali-Manohar

The Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 November 2020 in NMR in Biomedicine
Verified
Journal Article
Closed access
PDF file
CCCristina Cudalbu
Cristina Cudalbu
KBKevin L. Behar
Kevin L. Behar
PBPallab K. Bhattacharyya
Pallab K. Bhattacharyya
Wolfgang BognerWolfgang Bogner
Wolfgang Bogner
TBTamas Borbath
Tamas Borbath
Vladimir MlynarikVladimir Mlynarik
Vladimir Mlynarik

31 January 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
SMSaipavitra Murali‐Manohar
Saipavitra Murali‐Manohar
TBTamas Borbath
Tamas Borbath
AWAndrew Martin Wright
Andrew Martin Wright
BSBrian Soher
Brian Soher
RMRalf Mekle
Ralf Mekle
AHAnke Henning
Anke Henning
Purpose: Relaxation times can contribute to spectral assignment. In this study, effective T2 relaxation times () of macromolecules are reported for gray and white matter–rich voxels in the human brain at 9.4 T. The of macromolecules are helpful to understand their behavior and the effect they have on metabolite quantification. Additionally, for absolute quantification of metabolites with magnetic resonance spectroscopy, appropriate T2 values of metabolites must be considered. The T2 relaxation times of metabolites are calculated after accounting for TE/sequence‐specific macromolecular baselines.Methods: Macromolecular and metabolite spectra for a series of TEs were acquired at 9.4 T using double inversion–recovery metabolite‐cycled semi‐LASER and metabolite‐cycled semi‐LASER, respectively. The T2 relaxation times were calculated by fitting the LCModel relative amplitudes of macromolecular peaks and metabolites to a mono‐exponential decay across the TE series. Furthermore, absolute concentrations of metabolites were calculated using the estimated relaxation times and internal water as reference.Results: The of macromolecules are reported, which range from 13 ms to 40 ms, whereas, for metabolites, they range from 40 ms to 110 ms. Both macromolecular and metabolite T2 relaxation times are observed to follow the decreasing trend, with increasing B0. The linewidths of metabolite singlets can be fully attributed to T2 and B0 components. However, in addition to these components, macromolecule linewidths have contributions from J‐coupling and overlapping resonances.Conclusion: The T2 relaxation times of all macromolecular and metabolite peaks at 9.4 T in vivo are reported for the first time. Metabolite relaxation times were used to calculate the absolute metabolite concentrations.

17 October 2018 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
IGIoannis‐Angelos Giapitzakis
Ioannis‐Angelos Giapitzakis
TBTamas Borbath
Tamas Borbath
SMSaipavitra Murali‐Manohar
Saipavitra Murali‐Manohar
NANikolai Avdievich
Nikolai Avdievich
AHAnke Henning
Anke Henning

12 May 2016 in Applied Physics A
Verified
Journal Article
Closed access
PDF file
NPNeena Prasad
Neena Prasad
SMSaipavitra V. M. M
Saipavitra V. M. M
HSHariharan Swaminathan
Hariharan Swaminathan
PTPandiyarajan Thangaraj
Pandiyarajan Thangaraj
Ramalinga Viswanathan MangalarajaRamalinga Viswanathan Mangalaraja
Ramalinga Viswanathan Mangalaraja
KBKarthikeyan Balasubramanian
Karthikeyan Balasubramanian

14 November 2022 in NMR in Biomedicine
Verified
Journal Article
Closed access
HZHelge J. Zöllner
Helge J. Zöllner
CDChristopher W. Davies‐Jenkins
Christopher W. Davies‐Jenkins
SMSaipavitra Murali‐Manohar
Saipavitra Murali‐Manohar
TGTao Gong
Tao Gong
SHSteve C. N. Hui
Steve C. N. Hui
GOGeorg Oeltzschner
Georg Oeltzschner

13 August 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
TBTamas Borbath
Tamas Borbath
SMSaipavitra Murali‐Manohar
Saipavitra Murali‐Manohar
JDJohanna Dorst
Johanna Dorst
AWAndrew Martin Wright
Andrew Martin Wright
AHAnke Henning
Anke Henning
Purpose: Accurate and precise MRS fitting is crucial for metabolite concentration quantification of1H‐MRS spectra. LCModel, a spectral fitting software, has shown to have certain limitations to perform advanced spectral fitting by previous literature. Herein, we propose an open‐source spectral fitting algorithm with adaptive spectral baseline determination and more complex cost functions.Theory: The MRS spectra are characterized by several parameters, which reflect the environment of the contributing metabolites, properties of the acquisition sequence, or additional disturbances. Fitting parameters should accurately describe these parameters. Baselines are also a major contributor to MRS spectra, in which smoothness of the spline baselines used for fitting can be adjusted based on the properties of the spectra. Three different cost functions used for the minimization problem were also investigated.Methods: The newly developed ProFit‐1D fitting algorithm is systematically evaluated for simulations of several types of possible in vivo parameter variations. Although accuracy and precision are tested with simulated spectra, spectra measured in vivo at 9.4 T are used for testing precision using subsets of averages. ProFit‐1D fitting results are also compared with LCModel.Results: Both ProFit‐1D and LCModel fitted the spectra well with induced parameter and baseline variations. ProFit‐1D proved to be more accurate than LCModel for simulated spectra. However, LCModel showed a somewhat increased precision for some spectral simulations and for in vivo data.Conclusion: The open‐source ProFit‐1D fitting algorithm demonstrated high accuracy while maintaining precise metabolite concentration quantification. Finally, through the newly proposed cost functions, new ways to improve fitting were shown.