Purpose: Relaxation times can contribute to spectral assignment. In this study, effective T2 relaxation times () of macromolecules are reported for gray and white matter–rich voxels in the human brain at 9.4 T. The of macromolecules are helpful to understand their behavior and the effect they have on metabolite quantification. Additionally, for absolute quantification of metabolites with magnetic resonance spectroscopy, appropriate T2 values of metabolites must be considered. The T2 relaxation times of metabolites are calculated after accounting for TE/sequence‐specific macromolecular baselines.Methods: Macromolecular and metabolite spectra for a series of TEs were acquired at 9.4 T using double inversion–recovery metabolite‐cycled semi‐LASER and metabolite‐cycled semi‐LASER, respectively. The T2 relaxation times were calculated by fitting the LCModel relative amplitudes of macromolecular peaks and metabolites to a mono‐exponential decay across the TE series. Furthermore, absolute concentrations of metabolites were calculated using the estimated relaxation times and internal water as reference.Results: The of macromolecules are reported, which range from 13 ms to 40 ms, whereas, for metabolites, they range from 40 ms to 110 ms. Both macromolecular and metabolite T2 relaxation times are observed to follow the decreasing trend, with increasing B0. The linewidths of metabolite singlets can be fully attributed to T2 and B0 components. However, in addition to these components, macromolecule linewidths have contributions from J‐coupling and overlapping resonances.Conclusion: The T2 relaxation times of all macromolecular and metabolite peaks at 9.4 T in vivo are reported for the first time. Metabolite relaxation times were used to calculate the absolute metabolite concentrations.
Purpose: Accurate and precise MRS fitting is crucial for metabolite concentration quantification of1H‐MRS spectra. LCModel, a spectral fitting software, has shown to have certain limitations to perform advanced spectral fitting by previous literature. Herein, we propose an open‐source spectral fitting algorithm with adaptive spectral baseline determination and more complex cost functions.Theory: The MRS spectra are characterized by several parameters, which reflect the environment of the contributing metabolites, properties of the acquisition sequence, or additional disturbances. Fitting parameters should accurately describe these parameters. Baselines are also a major contributor to MRS spectra, in which smoothness of the spline baselines used for fitting can be adjusted based on the properties of the spectra. Three different cost functions used for the minimization problem were also investigated.Methods: The newly developed ProFit‐1D fitting algorithm is systematically evaluated for simulations of several types of possible in vivo parameter variations. Although accuracy and precision are tested with simulated spectra, spectra measured in vivo at 9.4 T are used for testing precision using subsets of averages. ProFit‐1D fitting results are also compared with LCModel.Results: Both ProFit‐1D and LCModel fitted the spectra well with induced parameter and baseline variations. ProFit‐1D proved to be more accurate than LCModel for simulated spectra. However, LCModel showed a somewhat increased precision for some spectral simulations and for in vivo data.Conclusion: The open‐source ProFit‐1D fitting algorithm demonstrated high accuracy while maintaining precise metabolite concentration quantification. Finally, through the newly proposed cost functions, new ways to improve fitting were shown.