Understanding of the mechanics of the brittle‐ductile transition (BDT) in porous limestone is significantly more challenging than for sandstone because of the lack of consistent acoustic emission activity in limestone, meaning that one must rely on alternative techniques. In this paper, we investigate systematically the failure modes in Indiana limestone using X‐ray microComputed Tomography imaging (μCT) and Digital Volume Correlation (DVC). Our new mechanical data show that the envelope for the onset of shear‐enhanced compaction can be well approximated by an elliptical cap. The DVC analysis revealed the development of shear bands through the BDT, but no evidence of compaction bands. The shear band angles were between 29° and 46° with respect to the maximum principal stress. Compiling these new results with published data on Purbeck and Leitha limestones, we showed that inelastic compaction in each of these dual porosity allochemical limestones was in a good agreement with the normality condition, as defined in plasticity theory. Comparison of the observed failure modes with predictions based on bifurcation analysis showed that the shear band angles are consistently smaller than the theoretical predictions.
The acetabular rim extension (ACE-X) implant is a custom-made three-dimensionally printed titanium device designed for the treatment of canine hip dysplasia. In this study, 34 dogs (61 hips) underwent ACE-X implantation, and assessments were conducted using computed tomography, force plate analysis, Ortolani’s test, and the Helsinki chronic pain index (HCPI) questionnaires at five intervals: the pre-operative day, the surgery day, and the 1.5-month, 3-month, and 12-month follow-ups. Statistically significant increases in femoral head coverage with a negative Ortolani subluxation test were observed immediately after surgery and persisted throughout the study. Osteoarthritis (OA) scores remained stable, but osteophyte size significantly increased between the surgery day and the 12-month follow-up, especially in hips with a baseline OA score of 2 compared to those with a score of 1. The force plate data showed no significant changes during the study. The HCPI demonstrated a significant decrease in pain score from pre-operative value to six-week follow-up and gradually decreased over time. Major complications were identified in six hips (9.8%) of four dogs. In conclusion, the ACE-X implant effectively increased femoral head coverage, eliminated subluxation, and provided long-term pain relief with minimal complications, benefiting over 90% of the study population. The study supports the ACE-X implant as a valuable alternative treatment for canine hip dysplasia.
We studied the brittle-ductile transition in three porous carbonates, Indiana, USA, Majella, Italy, and Leitha, Austria, with porosity ranging between 16 and 31%. A series of triaxial experiments were performed at room temperature, constant strain rate, and at effective pressures ranging from 5 to 150 MPa. Several sets of X-ray Tomography images were acquired before and after deformation. 3D digital image correlation (DIC) was performed on the images of the intact and deformed samples. The use of 3D-volumetric DIC allowed us to map out the subtle development of strain localization associated with the transition from brittle faulting to cataclastic flow in the three limestones. Our observations showed that strain localization may develop at relatively small axial strains of ~1%, in both the brittle faulting and transitional regimes. In Majella limestone (porosity = 31%), the localized deformation involved both shear and compaction. Compaction bands were only observed in less cemented samples of Leitha limestone.
Rocksalt formations are critical candidates for storing natural gas, hydrogen, compressed air energy, and radioactive waste. While pure, undisturbed rock salt deposits exhibit low porosity and impermeability when buried deeply, excavation leads to near-field microcracking and dilatancy in the salt, increasing porosity and permeability. Over time, the connectivity of brine- or water-vapor-filled microcrack networks in deformation-damaged salt is expected to decrease, partly due to dissolution-precipitation healing. In this study, we employ 4D (time-resolved 3D) microtomography to investigate the long-term evolution of dilated grain boundary and microcrack networks developed in deformation-damaged natural salt through brine-assisted processes. Our findings reveal substantial microstructural modification and healing occurring over periods ranging from days to a few months. Cracks and dilated grain boundaries undergo crystallographic faceting, necking, and migration, effectively "recrystallizing" the material and resulting in increased tortuosity and decreased connectivity of the crack network. Understanding the complex interplay between microcracking, healing, and permeability changes in deformation-damaged rock salt is of utmost importance for optimizing storage and disposal applications in geomechanics and physical chemistry. Our research contributes valuable insights to this field and informs the sustainable development and management of rock salt formations for diverse energy storage and waste management needs.
The ACEtabular rim eXtension (ACE-X) implant is a custom-made 3-dimensional-printed titanium device designed for the treatment of canine hip dysplasia. Thirty-four dogs (61 hips) underwent ACE-X implantation, and assessments were conducted using computed tomography, force plate analysis, Ortolani’s test, and Helsinki Chronic Pain Index (HCPI) questionnaires at five intervals: pre-operative day, surgery day, 1.5-month, 3-month, and 12-month follow-up. Statistically significant increases in femoral head coverage with negative Ortolani subluxation test were observed immediately after surgery and persisted throughout the study. Osteoarthritis (OA) scores remained stable, but osteophyte size significantly increased between the surgery day and the 12-month follow-up, especially in hips with a baseline OA score of 2 compared to those with a score of 1. Force plate data showed no significant changes during the study. The HCPI demonstrated a significant decrease in pain score from pre-operative value to 6-week follow-up and gradually decreased over time. Major complications were identified in 6 hips (9.8%) of 4 dogs. In conclusion, the ACE-X implant effectively increased femoral head coverage, eliminated subluxation, and provided long-term pain relief with minimal complications, benefiting over 90% of the study population. The study supports the ACE-X implant as a secure and valuable treatment for canine hip dysplasia.