Edward William Johnston

Edward William Johnston

Auto-generated profile, based on publicly available information

Edward William Johnston

Interventional Radiology, Royal Marsden Hospital, London, UK

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2019 in Radiology
Verified
Journal Article
Open access
EJEdward W. Johnston
Edward W. Johnston
EBElisenda Bonet-Carne
Elisenda Bonet-Carne
UFUran Ferizi
Uran Ferizi
BYBen Yvernault
Ben Yvernault
HPHayley Pye
Hayley Pye
SPShonit Punwani
Shonit Punwani
The intracellular volume fraction derived from Vascular, Extracellular, and Restricted Diffusion for Cytometry in Tumors (VERDICT) MRI enables better differentiation of a Gleason 4 lesion from beni... Background Biologic specificity of diffusion MRI in relation to prostate cancer aggressiveness may improve by examining separate components of the diffusion MRI signal. The Vascular, Extracellular,...

21 October 2016 in BMC Cancer
Verified
Journal Article
Open access
PDF file
EJEdward Johnston
Edward Johnston
HPHayley Pye
Hayley Pye
EBElisenda Bonet-Carne
Elisenda Bonet-Carne
EPEleftheria Panagiotaki
Eleftheria Panagiotaki
DPDominic Patel
Dominic Patel
SPShonit Punwani
Shonit Punwani
Whilst multi-parametric magnetic resonance imaging (mp-MRI) has been a significant advance in the diagnosis of prostate cancer, scanning all patients with elevated prostate specific antigen (PSA) levels is considered too costly for widespread National Health Service (NHS) use, as the predictive value of PSA levels for significant disease is poor. Despite the fact that novel blood and urine tests are available which may predict aggressive disease better than PSA, they are not routinely employed due to a lack of clinical validity studies. Furthermore approximately 40 % of mp-MRI studies are reported as indeterminate, which can lead to repeat examinations or unnecessary biopsy with associated patient anxiety, discomfort, risk and additional costs. We aim to clinically validate a panel of minimally invasive promising blood and urine biomarkers, to better select patients that will benefit from a multiparametric prostate MRI. We will then test whether the performance of the mp-MRI can be improved by the addition of an advanced diffusion-weighted MRI technique, which uses a biophysical model to characterise tissue microstructure called VERDICT; Vascular and Extracellular Restricted Diffusion for Cytometry in Tumours. INNOVATE is a prospective single centre cohort study in 365 patients. mp-MRI will act as the reference standard for the biomarker panel. A clinical outcome based reference standard based on biopsy, mp-MRI and follow-up will be used for VERDICT MRI. We expect the combined effect of biomarkers and VERDICT MRI will improve care by better detecting aggressive prostate cancer early and make mp-MRI before biopsy economically viable for universal NHS adoption. INNOVATE is registered on ClinicalTrials.gov, with reference NCT02689271 .

1 December 2022 in Radiology
Verified
Journal Article
Open access
SSSaurabh Singh
Saurabh Singh
HRHarriet Rogers
Harriet Rogers
BKBaris Kanber
Baris Kanber
JCJoey Clemente
Joey Clemente
HPHayley Pye
Hayley Pye
SPShonit Punwani
Shonit Punwani
Fractional intracellular volume–derived Vascular, Extracellular, and Restricted Diffusion for Cytometry in Tumor analysis of multiparametric MRI findings resulted in better classification of clinic... Background In men suspected of having prostate cancer (PCa), up to 50% of men with positive multiparametric MRI (mpMRI) findings (Prostate Imaging Reporting and Data System [PI-RADS] or Likert scor...

1 December 2017 in British Journal of Radiology
Verified
Journal Article
Open access
MBMrishta Brizmohun
Mrishta Brizmohun
HSHarbir Singh Sidhu
Harbir Singh Sidhu
Nikolaos DikaiosNikolaos Dikaios
Nikolaos Dikaios
EJEdward W Johnston
Edward W Johnston
LSLucy Am Simmons
Lucy Am Simmons
SPShonit Punwani
Shonit Punwani
Objective: To determine whether indeterminate (Likert-score 3/5) peripheral zone (PZ) multiparametric MRI (mpMRI) studies are classifiable by prostate-specific antigen (PSA), PSA density (PSAD), Prostate Imaging Reporting And Data System version 2 (PI-RADS_v2) rescoring and morphological MRI features. Methods: Men with maximum Likert-score 3/5 within their PZ were retrospectively selected from 330 patients who prospectively underwent prostate mpMRI (3 T) without an endorectal coil, followed by 20-zone transperineal template prostate mapping biopsies +/- focal lesion-targeted biopsy. PSAD was calculated using pre-biopsy PSA and MRI-derived volume. Two readers A and B independently assessed included men with both Likert-assessment and PI-RADS_v2. Both readers then classified mpMRI morphological features in consensus. Men were divided into two groups: significant cancer (≥ Gleason 3 + 4) or insignificant cancer (≤ Gleason 3 + 3)/no cancer. Comparisons between groups were made separately for PSA & PSAD using Mann–Whitney test and morphological descriptors with Fisher’s exact test. PI-RADS_v2 and Likert-assessment were descriptively compared and percentage inter-reader agreement calculated. Results: 76 males were eligible for PSA & PSAD analyses, 71 for PI-RADS scoring, and 67 for morphological assessment (excluding significant image artefacts). Unlike PSA (p = 0.915), PSAD was statistically different (p = 0.004) between the significant [median: 0.19 ng ml– 2 (interquartile range: 0.13–0.29)] and non-significant/no cancer [median: 0.13 ng ml– 2 (interquartile range: 0.10–0.17)] groups. Presence of mpMRI morphological features was not significantly different between groups. Subjective Likert-assessment discriminated patients with significant cancer better than PI-RADS_v2. Inter-reader percentage agreement was 83% for subjective Likert-assessment and 56% for PI-RADS_v2. Conclusion: PSAD may categorize presence of significant cancer in patients with Likert-scored 3/5 PZ mpMRI findings. Advances in knowledge: PSAD may be used in indeterminate PZ mpMRI to guide decisions between biopsy vs monitoring.

6 December 2021 in Cancers
Verified
Journal Article
Open access
PDF file
PMPritesh Mehta
Pritesh Mehta
MAMichela Antonelli
Michela Antonelli
SSSaurabh Singh
Saurabh Singh
NGNatalia Grondecka
Natalia Grondecka
EJEdward W. Johnston
Edward W. Johnston
SOSébastien Ourselin
Sébastien Ourselin
Multiparametric magnetic resonance imaging (mpMRI) of the prostate is used by radiologists to identify, score, and stage abnormalities that may correspond to clinically significant prostate cancer (CSPCa). Automatic assessment of prostate mpMRI using artificial intelligence algorithms may facilitate a reduction in missed cancers and unnecessary biopsies, an increase in inter-observer agreement between radiologists, and an improvement in reporting quality. In this work, we introduce AutoProstate, a deep learning-powered framework for automatic MRI-based prostate cancer assessment. AutoProstate comprises of three modules: Zone-Segmenter, CSPCa-Segmenter, and Report-Generator. Zone-Segmenter segments the prostatic zones on T2-weighted imaging, CSPCa-Segmenter detects and segments CSPCa lesions using biparametric MRI, and Report-Generator generates an automatic web-based report containing four sections: Patient Details, Prostate Size and PSA Density, Clinically Significant Lesion Candidates, and Findings Summary. In our experiment, AutoProstate was trained using the publicly available PROSTATEx dataset, and externally validated using the PICTURE dataset. Moreover, the performance of AutoProstate was compared to the performance of an experienced radiologist who prospectively read PICTURE dataset cases. In comparison to the radiologist, AutoProstate showed statistically significant improvements in prostate volume and prostate-specific antigen density estimation. Furthermore, AutoProstate matched the CSPCa lesion detection sensitivity of the radiologist, which is paramount, but produced more false positive detections.

18 April 2023 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
EJEdward W. Johnston
Edward W. Johnston
JBJodie Basso
Jodie Basso
FSFrancisca Silva
Francisca Silva
AHArafat Haris
Arafat Haris
RJRobin L. Jones
Robin L. Jones
NFNicos Fotiadis
Nicos Fotiadis
Purpose: Radiofrequency ablation (RFA) is a curative treatment option for small lung metastases, which conventionally involves multiple freehand manipulations until the treating electrode is satisfactorily positioned. Stereotactic and robotic guidance has been gaining popularity for liver ablation, although has not been established in lung ablation. The purpose of this study is to determine the feasibility, safety, and accuracy of robotic RFA for pulmonary metastases, and compare procedures with a conventional freehand cohort. Methods: A single center study with prospective robotic cohort, and retrospective freehand cohort. RFA was performed under general anesthesia using high frequency jet ventilation and CT guidance. Main outcomes were (i) feasibility/technical success (ii) safety using Common Terminology Criteria for Adverse Events (iii) targeting accuracy (iv) number of needle manipulations for satisfactory ablation. Robotic and freehand cohorts were compared using Mann–Whitney U tests for continuous variables, and Fisher’s exact for categorical variables. Results: Thirty-nine patients (mean age 65 ± 13 years, 20 men) underwent ablation of 44 pulmonary metastases at single specialist cancer center between July 2019 and August 2022. 20 consecutive participants underwent robotic ablation, and 20 consecutive patients underwent freehand ablation. All 20/20 (100%) robotic procedures were technically successful, and none were converted to freehand procedures. There were 6/20 (30%) adverse events in the robotic cohort, and 15/20 (75%) in the freehand cohort (P = 0.01). Robotic placement was highly accurate with 6 mm tip-to-target distance (range 0–14 mm) despite out-of-plane approaches, with fewer manipulations than freehand placement (median 0 vs. 4.5 manipulations, P < 0.001 and 7/22, 32% vs. 22/22, 100%, P < 0.001). Conclusions: Robotic radiofrequency ablation of pulmonary metastases with general anesthesia and high frequency jet ventilation is feasible and safe. Targeting accuracy is high, and fewer needle/electrode manipulations are required to achieve a satisfactory position for ablation than freehand placement, with early indications of reduced complications.