25 January 2017 in Computer Methods and Programs in Biomedicine
Background and Objective: Optimal targets for persistent atrial fibrillation (persAF) ablation are still debated. Atrial regions hosting high dominant frequency (HDF) are believed to participate in the initiation and maintenance of persAF and hence are potential targets for ablation, while rotor ablation has shown promising initial results. Currently, no commercially available system offers the capability to automatically identify both these phenomena. This paper describes an integrated 3D software platform combining the mapping of both frequency spectrum and phase from atrial electrograms (AEGs) to help guide persAF ablation in clinical cardiac electrophysiological studies. Methods: 30 s of 2048 non-contact AEGs (EnSite Array, St. Jude Medical) were collected and analyzed per patient. After QRST removal, the AEGs were divided into 4 s windows with a 50% overlap. Fast Fourier transform was used for DF identification. HDF areas were identified as the maximum DF to 0.25 Hz below that, and their centers of gravity (CGs) were used to track their spatiotemporal movement. Spectral organization measurements were estimated. Hilbert transform was used to calculate instantaneous phase. Results: The system was successfully used to guide catheter ablation for 10 persAF patients. The mean processing time was 10.4 +/- 1.5 min, which is adequate comparing to the normal electrophysiological (EP) procedure time (120 similar to 180 min). Conclusions: A customized software platform capable of measuring different forms of spatiotemporal AEG analysis was implemented and used in clinical environment to guide persAF ablation. The modular nature of the platform will help electrophysiological studies in understanding of the underlying AF mechanisms. (C) 2017 Elsevier B.V. All rights reserved.
17 December 2021 in Journal of Cardiovascular Electrophysiology
15 July 2021 in Heart International
Paroxysmal supraventricular tachycardia (PSVT) defines a group of cardiac arrhythmias where the underlying mechanism is dependent upon structures at or above
13 December 2021 in HeartRhythm Case Reports
1 June 2020 in EP Europace
Funding Acknowledgements: This work was supported by the NIHR Leicester Biomedical Research Centre. XL was funded by MRC(MR/S037306/1) and BHF (PG/18/33/33780) Background: It remains controversial as to whether rotors detected using phase mapping during persistent atrial fibrillation (persAF) represent main drivers of the underlying mechanism as others found rotors to be located near line of conduction block. Regional electrogram desynchronization (RED) has been suggested as successful targets for persAF ablation, but automatic tools and quantitative measures are lacking. Purpose: We aim to use mean phase coherence (MPC) to automatically identify RED regions during persAF. This method was compared with phase singularity density (PSD) maps. Methods: Patients undergoing left atrial (LA) persAF ablation were enrolled (n = 10). 2048-channel virtual electrograms (VEGMs) were collected from each patient using non-contact mapping (St Jude Velocity System, Ensite Array) for 10 seconds. To remove far field ventricular activities, QRS onset and T wave end locations were detected from ECG lead I (Figure 1A) and only the VEGM segments from T end to QRS onset were included in the analysis. VEGMs were reconstructed using sinusoidal wavelets fitting and the phase of VEGMs determined using Hilbert transform. Phase singularities (PS) were detected using the topological charge method and repetitive PSD maps were generated. RED was defined as the average of MPC of each node against direct neighbouring nodes on the 3D mesh (Figure 1A-B). Linear regression analysis was used to compare the average MPC vs. PSD and vs. the standard deviation of MPC (MPC_SD). Results: A total of 221,184 VEGM segments were analysed with mean duration of 364.2 milliseconds. MPC has shown the ability to quantify the level of synchronisation between VEGMs (Figure 1B). Inverse correlation was found between PSD and average MPC values for all 10 patients (p < 0.0001, Figure 1C). Average MPC and MPC_SD were found to be inversely correlated (p < 0.0001, Figure 1C). Spatially, similar graphic patterns can be found from LA MPC maps and PSD maps for all patients (Figure 1D). Conclusion: We have proposed a method to quantify the level of synchronisation between VEGMs. Phase density mapping showed a considerable agreement with RED regions reflecting regional conducting delays, which supports the previous finding where rotors found at conduction block. Inverse correlation between local average MPC and MPC_SD suggests that conduction delays of the identified regions are not heterogenous, posing directional preferences. Rather than solely looking for rotational activities, this method could identify comprehensive RED regions, which may also explain the conflicting results from different studies targeting rotational activities, where incomplete subsets of RED regions could have been targeted. Atrial RED regions can easily be identified with simultaneously collected electrograms from multi-polar catheters and should be targeted in future persAF studies. Abstract Figure 1