Djamel Ziane

Djamel Ziane

Auto-generated profile, based on publicly available information

Djamel Ziane

Laboratoire National de Métrologie et d’Essais (LNE) , 29 Avenue Roger Hennequin, 78190 Trappes

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2023 in Metrologia
Verified
Journal Article
Closed access
MSM Stock
M Stock
PCP Conceição
P Conceição
HFH Fang
H Fang
FBF Bielsa
F Bielsa
AKA Kiss
A Kiss
HAH Ahmedov
H Ahmedov
Main text: This report describes the second CCM key comparison of realizations of the kilogram definition based on the fixed numerical value of the Planck constant, which came into force on 20 May 2019. The objectives were to determine the level of agreement between realizations of the kilogram using Kibble and joule balances and the x-ray crystal density (XRCD) method and to provide input for the calculation of the second "consensus value" of the kilogram. The consensus value serves as the basis for an internationally coordinated dissemination of the kilogram and is updated after each new key comparison. Its use will continue until satisfactory agreement between realization experiments has been achieved. Another objective was the determination of the reproducibility of the realization experiments by comparing the new results with those of the first key comparison of kilogram realizations, CCM.M-K8.2019. The comparison was organized by the BIPM and had nine participants. The BIPM, LNE, METAS, NIST, NRC and UME operated Kibble balances, the NIM used a joule balance and the NMIJ and the PTB participated using 28Si spheres, the masses of which were determined with the XRCD method. These realization methods were used to calibrate 1 kg mass standards under vacuum or in air. The standards were sent to the BIPM where they were compared with each other and with BIPM Pt-Ir working standards. The latter were calibrated traceable to the International Prototype of the Kilogram (IPK), the mass of which served as the definition of the kilogram until 20 May 2019. The results of the weighings at the BIPM together with the measurement results communicated by the participants allowed comparison of the values attributed to 1 kg mass standards using the realization experiments of the participants. The level of agreement between mass determinations with the realization experiments and the BIPM as-maintained mass unit, traceable to the Planck constant through the mass of the International Prototype of the Kilogram, could also be deduced. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

1 December 2025 in Metrologia
Verified
Journal Article
Closed access
MTM Thomas
M Thomas
DZD Ziane
D Ziane
PEP Espel
P Espel
KDK Dougdag
K Dougdag
FBF Beaudoux
F Beaudoux
MTMathieu Taupin
Mathieu Taupin
Kibble balances are complex electromechanical instruments that enable the determination of mass within the SI by linking it to the Planck constant h , the defining constant of the mass unit. The LNE has been developing its own Kibble balance since 2002, with the most recent improvements focusing on the implementation of a contactless linear motor for the dynamic phase and the fine adjustment of the beam’s orientation with respect to the horizontal plane for the static phase. In 2024, two mass calibration campaigns were carried out using the LNE Kibble balance: first with an iridium standard (DB1), and then with a platinum-iridium standard (W1). Both artefacts have a nominal mass of 500 g, and their masses were determined with relative standard uncertainties of 3.1 ⋅ 10 − 8 and 3.5 ⋅ 10 − 8 respectively ( k  =   1 ).

21 May 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MTMatthieu Thomas
Matthieu Thomas
PEPatrick Espel
Patrick Espel
KDKamel Dougdag
Kamel Dougdag
DZDjamel Ziane
Djamel Ziane
In a Kibble balance experiment, the mass value is determined by calculating the geometric factor of the magnetic circuit - coil set up. This factor is calculated using two different interleaved methods: the weighing phase and the dynamic phase. This paper presents improvements in the noise measurement of the geometric factor in both the dynamic and static phases from 2017 to 2024, ultimately reducing the noise associated with the determination of the value of a mass of the LNE Kibble balance to a value of 4·10−8 for an integration time of 1 day (a 6 fold improvement with respect to 2017).

1 August 2026 in Review of Scientific Instruments
Verified
Journal Article
Open access
MTMathieu Taupin
Mathieu Taupin
KDK. Dougdag
K. Dougdag
DZD. Ziane
D. Ziane
FCF. Couëdo
F. Couëdo
A paradigm shift in achieving (sub-)Kelvin environments is currently underway with the democratization of cryogen-free cryocoolers. This transition is driven by their user-friendly, continuous operation and the elimination of liquid helium, which is becoming increasingly scarce and expensive. Thanks to their large sample space and high cooling power, these systems can host superconducting magnets, making them an ideal platform for quantum technologies, materials science, low-temperature detectors, and even medical applications. The drawback is that this type of system is inherently based on gas compression that induces a certain level of vibrations and electromagnetic perturbations, which can potentially prevent the determination of low amplitude signals or spoil their stability. In this paper, we demonstrate that pulse-tube based cryocoolers can be used for electrical precision measurements under a high magnetic field, using a commercial cryomagnetic system combined with a customized coaxial cryoprobe. A parts-per-billion level of measurement uncertainty in resistance determination, based on the quantum Hall resistance standard, is achievable, matching the state-of-the-art involving conventional cryostats based on liquid helium. We performed an extensive characterization of the cryomagnetic system to determine the levels of vibrations and electromagnetic perturbations, revealing the drastic effect of the magnetic field on the electromagnetic noise level. While interferences can occur in some measurements, others appear immune to the perturbations, meaning that the cryogen-free system is not inherently a source of disturbance. The set of characterization measurements presented here is easily implementable in laboratories, which can help to determine the vibrations and electromagnetic pollution generated by any cryocooler.