Vadym Kedych

Vadym Kedych

Auto-generated profile, based on publicly available information

Vadym Kedych

Paul Scherrer Institute

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 June 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Open access
WKW. Krüger
W. Krüger
TBThomas Bergauer
Thomas Bergauer
TGT. Galatyuk
T. Galatyuk
AHA. Hirtl
A. Hirtl
VKV. Kedych
V. Kedych
CWCh. Wendisch
Ch. Wendisch

1 November 2026 in IEEE Transactions on Electron Devices
Verified
Journal Article
Open access
SLShuqi Li
Shuqi Li
ABAnna Bergamaschi
Anna Bergamaschi
Ashish BishtAshish Bisht
Ashish Bisht
MBMaurizio Boscardin
Maurizio Boscardin
MBMartin Brückner
Martin Brückner
JZJiaguo Zhang
Jiaguo Zhang

1 October 2026 in Journal of Instrumentation
Verified
Journal Article
Open access
JMJonathan Mulvey
Jonathan Mulvey
DGDominic Greiffenberg
Dominic Greiffenberg
BSBernd Schmitt
Bernd Schmitt
ABAnna Bergamaschi
Anna Bergamaschi
MBMartin Brückner
Martin Brückner
JZJiaguo Zhang
Jiaguo Zhang
The upgraded Swiss Light Source (SLS 2.0) increases the need for high-Z detector systems with improved detection efficiency for hard X-rays compared with silicon. Two candidate high-Z sensor materials, cadmium zinc telluride (CZT) and cadmium telluride (CdTe), have undergone fundamental characterisation at PSI using the JUNGFRAU readout ASIC. Two variants of each material were investigated: Schottky and Ohmic CdTe, and spectroscopic and high-flux CZT. Measurements include current-voltage characteristics, pixel-resolved leakage current and noise, flat-field response, and energy resolution. Both CZT sensors exhibited a very low mean leakage current of 0.60 pA and 0.18 pA per pixel for spectroscopic and high-flux CZT, respectively. Ohmic CdTe showed a substantially higher mean leakage current of 65.81 pA per pixel, while Schottky CdTe showed much lower mean leakage current (0.62 pA) but contained a significant population of high-leakage-current pixels. At 59.54 keV, both CZT sensors achieved an energy resolution of approximately 3.5 keV FWHM using 3×3 clusters, compared with 4.3 keV for Ohmic CdTe and 5.9 keV for Schottky CdTe. Ohmic CdTe additionally required approximately two hours after biasing for its leakage current and pedestal to stabilise. Both CZT sensors could be operated at full duty cycle with a 500 μs exposure time, with only a small reduction in available dynamic range. Overall, the CZT sensors showed the most favourable performance of the devices investigated, although further measurements across a larger number of sensors are required to assess sensor-to-sensor variation and production yield.