Chromium compensated GaAs or GaAs:Cr sensors provided by the Tomsk State University (Russia) were characterized using the low noise, charge integrating readout chip JUNGFRAU with a pixel pitch of 75 × 75 µm2 regarding its application as an X-ray detector at synchrotrons sources or FELs. Sensor properties such as dark current, resistivity, noise performance, spectral resolution capability and charge transport properties were measured and compared with results from a previous batch of GaAs:Cr sensors which were produced from wafers obtained from a different supplier. The properties of the sample from the later batch of sensors from 2017 show a resistivity of 1.69 × 109 Ω/cm, which is 47% higher compared to the previous batch from 2016. Moreover, its noise performance is 14% lower with a value of (101.65 ± 0.04) e− ENC and the resolution of a monochromatic 60 keV photo peak is significantly improved by 38% to a FWHM of 4.3%. Likely, this is due to improvements in charge collection, lower noise, and more homogeneous effective pixel size. In a previous work, a hole lifetime of 1.4 ns for GaAs:Cr sensors was determined for the sensors of the 2016 sensor batch, explaining the so-called “crater effect” which describes the occurrence of negative signals in the pixels around a pixel with a photon hit due to the missing hole contribution to the overall signal causing an incomplete signal induction. In this publication, the “crater effect” is further elaborated by measuring GaAs:Cr sensors using the sensors from 2017. The hole lifetime of these sensors was 2.5 ns. A focused photon beam was used to illuminate well defined positions along the pixels in order to corroborate the findings from the previous work and to further characterize the consequences of the “crater effect” on the detector operation.
Hybrid pixel detectors have become indispensable at synchrotron and X-ray free-electron laser facilities thanks to their large dynamic range, high frame rate, low noise, and large area. However, at energies below 3 keV, the detector performance is often limited because of the poor quantum efficiency of the sensor and the difficulty in achieving single-photon resolution due to the low signal-to-noise ratio. In this paper, we address the quantum efficiency of silicon sensors by refining the design of the entrance window, mainly by passivating the silicon surface and optimizing the dopant profile of the n+ region. We present the measurement of the quantum efficiency in the soft X-ray energy range for silicon sensors with several process variations in the fabrication of planar sensors with thin entrance windows. The quantum efficiency for 250 eV photons is increased from almost 0.5% for a standard sensor to up to 62% as a consequence of these developments, comparable to the quantum efficiency of backside-illuminated scientific CMOS sensors. Finally, we discuss the influence of the various process parameters on quantum efficiency and present a strategy for further improvement.
Gotthard-II is a silicon microstrip detector developed for the European X-ray Free-Electron Laser (XFEL.EU). Its potential scientific applications include X-ray absorption/emission spectroscopy, hard X-ray high resolution single-shot spectrometry (HiREX), energy dispersive experiments at 4.5 MHz frame rate, beam diagnostics, as well as veto signal generation for pixel detectors. Gotthard-II uses a silicon microstrip sensor with a pitch of 50 μm or 25 μm and with 1280 or 2560 channels wire-bonded to readout chips (ROCs). In the ROC, an adaptive gain switching pre-amplifier (PRE), a fully differential Correlated-Double-Sampling (CDS) stage, an Analog-to-Digital Converter (ADC) as well as a Static Random-Access Memory (SRAM) capable of storing all the 2700 images in an XFEL.EU bunch train will be implemented. Several prototypes with different designs of the analogue front-end (PRE and CDS) and ADC test structures have been fabricated in UMC-110 nm CMOS technology and their performance has been evaluated. In this paper, the performance of the analogue front-end and ADC will be summarized.
Gotthard-II is a charge-integrating silicon microstrip detector developed for energy-dispersive experiments and X-ray photon beam diagnostics at the European X-ray Free-Electron Laser (EuXFEL). Its one-dimensional geometry, featuring fewer readout channels than pixel detectors, and its fast readout capability make it the only segmented detector able to perform experiments at a 4.5 MHz frame rate while capturing all 2700 X-ray pulses in a bunch train produced by the EuXFEL machine. The Gotthard-II detector was tested for single-photon sensitivity and dynamic range, meeting all specifications. In addition to FEL applications operating at a 4.5 MHz frame rate in burst mode, the detector supports continuous acquisition at up to 400 kHz and counting mode at ≤4.5 MHz for synchrotron applications. Experimental tests with standard samples using X-ray diffraction and X-ray emission spectroscopy were conducted at several beamlines of the Swiss Light Source (SLS) and EuXFEL. The measurement results were compared with those obtained using established detectors at these beamlines, demonstrating the performance of the detector in energy-dispersive experiments.
To enhance the spatial resolution of the MÖNCH 25 µm pitch hybrid pixel detector, deep learning models have been trained using both simulation and measurement data. Challenges arise when comparing simulation-based deep learning models to measurement-based models for electrons, as the spatial resolution achieved through simulations is notably inferior to that from measurements. Discrepancies are also observed when directly comparing X-ray simulations with measurements, particularly in the spectral output of single pixels. These observations collectively suggest that current simulations require optimization. To address this, the dynamics of charge carriers within the silicon sensor have been studied using Monte Carlo simulations, aiming to refine the charge transport modeling. The simulation encompasses the initial generation of the charge cloud, charge cloud drift, charge diffusion and repulsion, and electronic noise. The simulation results were validated with measurements from the MÖNCH detector for X-rays, and the agreement between measurements and simulations was significantly improved by accounting for the charge repulsion.