Alessandro Guazzi

Alessandro Guazzi

Auto-generated profile, based on publicly available information

Alessandro Guazzi

Insitute of Biomedical Engineering, University of Oxford, UK

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2014 in Physiological Measurement
Verified
Journal Article
Open access
LTL Tarassenko
L Tarassenko
MVM Villarroel
M Villarroel
AGA Guazzi
A Guazzi
JJJ Jorge
J Jorge
DCD A Clifton
D A Clifton
CPC Pugh
C Pugh
Remote sensing of the reflectance photoplethysmogram using a video camera typically positioned 1 m away from the patient's face is a promising method for monitoring the vital signs of patients without attaching any electrodes or sensors to them. Most of the papers in the literature on non-contact vital sign monitoring report results on human volunteers in controlled environments. We have been able to obtain estimates of heart rate and respiratory rate and preliminary results on changes in oxygen saturation from double-monitored patients undergoing haemodialysis in the Oxford Kidney Unit. To achieve this, we have devised a novel method of cancelling out aliased frequency components caused by artificial light flicker, using auto-regressive (AR) modelling and pole cancellation. Secondly, we have been able to construct accurate maps of the spatial distribution of heart rate and respiratory rate information from the coefficients of the AR model. In stable sections with minimal patient motion, the mean absolute error between the camera-derived estimate of heart rate and the reference value from a pulse oximeter is similar to the mean absolute error between two pulse oximeter measurements at different sites (finger and earlobe). The activities of daily living affect the respiratory rate, but the camera-derived estimates of this parameter are at least as accurate as those derived from a thoracic expansion sensor (chest belt). During a period of obstructive sleep apnoea, we tracked changes in oxygen saturation using the ratio of normalized reflectance changes in two colour channels (red and blue), but this required calibration against the reference data from a pulse oximeter.

23 September 2014 in Healthcare Technology Letters
Verified
Journal Article
Open access
PDF file
MVMauricio Villarroel
Mauricio Villarroel
AGAlessandro Guazzi
Alessandro Guazzi
JJJoão Jorge
João Jorge
SDSara Davis
Sara Davis
PWPeter Watkinson
Peter Watkinson
LTLionel Tarassenko
Lionel Tarassenko
Current technologies to allow continuous monitoring of vital signs in pre‐term infants in the hospital require adhesive electrodes or sensors to be in direct contact with the patient. These can cause stress, pain, and also damage the fragile skin of the infants. It has been established previously that the colour and volume changes in superficial blood vessels during the cardiac cycle can be measured using a digital video camera and ambient light, making it possible to obtain estimates of heart rate or breathing rate. Most of the papers in the literature on non‐contact vital sign monitoring report results on adult healthy human volunteers in controlled environments for short periods of time. The authors' current clinical study involves the continuous monitoring of pre‐term infants, for at least four consecutive days each, in the high‐dependency care area of the Neonatal Intensive Care Unit (NICU) at the John Radcliffe Hospital in Oxford. The authors have further developed their video‐based, non‐contact monitoring methods to obtain continuous estimates of heart rate, respiratory rate and oxygen saturation for infants nursed in incubators. In this Letter, it is shown that continuous estimates of these three parameters can be computed with an accuracy which is clinically useful. During stable sections with minimal infant motion, the mean absolute error between the camera‐derived estimates of heart rate and the reference value derived from the ECG is similar to the mean absolute error between the ECG‐derived value and the heart rate value from a pulse oximeter. Continuous non‐contact vital sign monitoring in the NICU using ambient light is feasible, and the authors have shown that clinically important events such as a bradycardia accompanied by a major desaturation can be identified with their algorithms for processing the video signal.

11 August 2015 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
AGAlessandro R. Guazzi
Alessandro R. Guazzi
MVMauricio Villarroel
Mauricio Villarroel
JJJoão Jorge
João Jorge
JDJonathan Daly
Jonathan Daly
MFMatthew C. Frise
Matthew C. Frise
LTLionel Tarassenko
Lionel Tarassenko
A novel method (Sophia) is presented to track oxygen saturation changes in a controlled environment using an RGB camera placed approximately 1.5 m away from the subject. The method is evaluated on five healthy volunteers (Fitzpatrick skin phenotypes II, III, and IV) whose oxygen saturations were varied between 80% and 100% in a purpose-built chamber over 40 minutes each. The method carefully selects regions of interest (ROI) in the camera image by calculating signal-to-noise ratios for each ROI. This allows it to track changes in oxygen saturation accurately with respect to a conventional pulse oximeter (median coefficient of determination, 0.85).

1 May 2017
Verified
Conference Paper
Closed access
JJJoao Jorge
Joao Jorge
MVMauricio Villarroel
Mauricio Villarroel
SCSitthichok Chaichulee
Sitthichok Chaichulee
AGAlessandro Guazzi
Alessandro Guazzi
SDSara Davis
Sara Davis
LTLionel Tarassenko
Lionel Tarassenko
An abnormal respiratory rhythm is an early indicator of physiological deterioration. It is of critical importance in the clinical management of critically-ill or premature infants, for whom apnoea of prematurity is a major concern. Nevertheless, respiratory signals are still largely disregarded in neonatal intensive care units due to the high prevalence of noise and high false alarm rates in conventional monitoring. To address this, we present a novel method for the extraction of respiration from camera-based measurements taken from the top-view of an incubator. A total of 107 events from 30 neonatal admissions were annotated by three clinical reviewers as either true cessations of breathing (physiologically relevant) or false (artefact-related). The events were divided into two independent groups for training and validation and our algorithm was trained to classify true cessations. We achieved a good classification performance with 9 out of 10 cessations and 7 out of 10 artefactual events correctly identified in the training set, and with 7 out of 10 cessations and 34 out of 44 artefactual events correctly identified in the out-of-sample test set. A reduction in false alarm rate of 77.3% was achieved.

1 January 2014
Verified
Conference Paper
Closed access
TPT. Papastylianou
T. Papastylianou
SLS. Laranjeira
S. Laranjeira
PTP. Thomson
P. Thomson
AGA. Guazzi
A. Guazzi
GCGari D. Clifford
Gari D. Clifford
MMM.A. Maraci
M.A. Maraci