Mauricio Villarroel

Prof. Mauricio Villarroel

Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford OX1 2JD, UK

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 September 2014 in Healthcare Technology Letters
Verified
Journal Article
Open access
PDF file
MVMauricio Villarroel
Mauricio Villarroel
AGAlessandro Guazzi
Alessandro Guazzi
JJJoão Jorge
João Jorge
SDSara Davis
Sara Davis
PWPeter Watkinson
Peter Watkinson
LTLionel Tarassenko
Lionel Tarassenko
Current technologies to allow continuous monitoring of vital signs in pre‐term infants in the hospital require adhesive electrodes or sensors to be in direct contact with the patient. These can cause stress, pain, and also damage the fragile skin of the infants. It has been established previously that the colour and volume changes in superficial blood vessels during the cardiac cycle can be measured using a digital video camera and ambient light, making it possible to obtain estimates of heart rate or breathing rate. Most of the papers in the literature on non‐contact vital sign monitoring report results on adult healthy human volunteers in controlled environments for short periods of time. The authors' current clinical study involves the continuous monitoring of pre‐term infants, for at least four consecutive days each, in the high‐dependency care area of the Neonatal Intensive Care Unit (NICU) at the John Radcliffe Hospital in Oxford. The authors have further developed their video‐based, non‐contact monitoring methods to obtain continuous estimates of heart rate, respiratory rate and oxygen saturation for infants nursed in incubators. In this Letter, it is shown that continuous estimates of these three parameters can be computed with an accuracy which is clinically useful. During stable sections with minimal infant motion, the mean absolute error between the camera‐derived estimates of heart rate and the reference value derived from the ECG is similar to the mean absolute error between the ECG‐derived value and the heart rate value from a pulse oximeter. Continuous non‐contact vital sign monitoring in the NICU using ambient light is feasible, and the authors have shown that clinically important events such as a bradycardia accompanied by a major desaturation can be identified with their algorithms for processing the video signal.

12 December 2019 in npj Digital Medicine
Verified
Journal Article
Open access
PDF file
MVMauricio Villarroel
Mauricio Villarroel
SCSitthichok Chaichulee
Sitthichok Chaichulee
JJJoao Jorge
Joao Jorge
SDSara Davis
Sara Davis
GGGabrielle Green
Gabrielle Green
LTLionel Tarassenko
Lionel Tarassenko
The implementation of video-based non-contact technologies to monitor the vital signs of preterm infants in the hospital presents several challenges, such as the detection of the presence or the absence of a patient in the video frame, robustness to changes in lighting conditions, automated identification of suitable time periods and regions of interest from which vital signs can be estimated. We carried out a clinical study to evaluate the accuracy and the proportion of time that heart rate and respiratory rate can be estimated from preterm infants using only a video camera in a clinical environment, without interfering with regular patient care. A total of 426.6 h of video and reference vital signs were recorded for 90 sessions from 30 preterm infants in the Neonatal Intensive Care Unit (NICU) of the John Radcliffe Hospital in Oxford. Each preterm infant was recorded under regular ambient light during daytime for up to four consecutive days. We developed multi-task deep learning algorithms to automatically segment skin areas and to estimate vital signs only when the infant was present in the field of view of the video camera and no clinical interventions were undertaken. We propose signal quality assessment algorithms for both heart rate and respiratory rate to discriminate between clinically acceptable and noisy signals. The mean absolute error between the reference and camera-derived heart rates was 2.3 beats/min for over 76% of the time for which the reference and camera data were valid. The mean absolute error between the reference and camera-derived respiratory rate was 3.5 breaths/min for over 82% of the time. Accurate estimates of heart rate and respiratory rate could be derived for at least 90% of the time, if gaps of up to 30 seconds with no estimates were allowed.

1 August 2011 in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Verified
Conference Paper
Open access
JLJoon Lee
Joon Lee
DSDaniel J. Scott
Daniel J. Scott
MVMauricio Villarroel
Mauricio Villarroel
GCGari D. Clifford
Gari D. Clifford
MSMohammed Saeed
Mohammed Saeed
RMRoger Mark
Roger Mark
The critical state of intensive care unit (ICU) patients demands close monitoring, and as a result a large volume of multi-parameter data is collected continuously. This represents a unique opportunity for researchers interested in clinical data mining. We sought to foster a more transparent and efficient intensive care research community by building a publicly available ICU database, namely Multiparameter Intelligent Monitoring in Intensive Care II (MIMIC-II). The data harnessed in MIMIC-II were collected from the ICUs of Beth Israel Deaconess Medical Center from 2001 to 2008 and represent 26,870 adult hospital admissions (version 2.6). MIMIC-II consists of two major components: clinical data and physiological waveforms. The clinical data, which include patient demographics, intravenous medication drip rates, and laboratory test results, were organized into a relational database. The physiological waveforms, including 125 Hz signals recorded at bedside and corresponding vital signs, were stored in an open-source format. MIMIC-II data were also deidentified in order to remove protected health information. Any interested researcher can gain access to MIMIC-II free of charge after signing a data use agreement and completing human subjects training. MIMIC-II can support a wide variety of research studies, ranging from the development of clinical decision support algorithms to retrospective clinical studies. We anticipate that MIMIC-II will be an invaluable resource for intensive care research by stimulating fair comparisons among different studies.

1 November 2019 in Physiological Measurement
Verified
Journal Article
Open access
PDF file
SCSitthichok Chaichulee
Sitthichok Chaichulee
MVMauricio Villarroel
Mauricio Villarroel
JJJoao Jorge
Joao Jorge
CACarlos Arteta
Carlos Arteta
KMKenny McCormick
Kenny McCormick
LTLionel Tarassenko
Lionel Tarassenko
Non-contact vital sign monitoring enables the estimation of vital signs, such as heart rate, respiratory rate and oxygen saturation (SpO2), by measuring subtle color changes on the skin surface using a video camera. For patients in a hospital ward, the main challenges in the development of continuous and robust non-contact monitoring techniques are the identification of time periods and the segmentation of skin regions of interest (ROIs) from which vital signs can be estimated. We propose a deep learning framework to tackle these challenges. Approach: This paper presents two convolutional neural network (CNN) models. The first network was designed for detecting the presence of a patient and segmenting the patient’s skin area. The second network combined the output from the first network with optical flow for identifying time periods of clinical intervention so that these periods can be excluded from the estimation of vital signs. Both networks were trained using video recordings from a clinical study involving 15 pre-term infants conducted in the high dependency area of the neonatal intensive care unit (NICU) of the John Radcliffe Hospital in Oxford, UK. Main results: Our proposed methods achieved an accuracy of 98.8% for patient detection, a mean intersection-over-union (IOU) score of 88.6% for skin segmentation and an accuracy of 94.5% for clinical intervention detection using two-fold cross validation. Our deep learning models produced accurate results and were robust to different skin tones, changes in light conditions, pose variations and different clinical interventions by medical staff and family visitors. Significance: Our approach allows cardio-respiratory signals to be continuously derived from the patient’s skin during which the patient is present and no clinical intervention is undertaken.

1 January 2011 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
LCLeo Anthony Celi
Leo Anthony Celi
RTRobin J. Tang
Robin J. Tang
MVMauricio Villarroel
Mauricio Villarroel
GDGuido Alejandro Davidzon
Guido Alejandro Davidzon
WLWilliam T. Lester
William T. Lester
HCHenry C. Chueh
Henry C. Chueh
In exploring an approach to decision support based on information extracted from a clinical database, we developed mortality prediction models of intensive care unit (ICU) patients who had acute kidney injury (AKI) and compared them against the Simplified Acute Physiology Score (SAPS). We used MIMIC, a public de‐identified database of ICU patients admitted to Beth Israel Deaconess Medical Center, and identified 1400 patients with an ICD9 diagnosis of AKI and who had an ICU stay ≥3 days. Multivariate regression models were built using the SAPS variables from the first 72 hours of ICU admission. All the models developed on the training set performed better than SAPS (AUC = 0.64, Hosmer‐Lemeshow p <0.001) on an unseen test set; the best model had an AUC = 0.74 and Hosmer‐Lemeshow p = 0.53. These findings suggest that local customized modeling might provide more accurate predictions. This could be the first step towards an envisioned individualized point‐of‐care probabilistic modeling using one′s clinical database.

28 October 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MVMauricio Villarroel
Mauricio Villarroel
JJJoão Jorge
João Jorge
DMDavid Meredith
David Meredith
SSSheera Sutherland
Sheera Sutherland
CPChris Pugh
Chris Pugh
LTLionel Tarassenko
Lionel Tarassenko
A clinical study was designed to record a wide range of physiological values from patients undergoing haemodialysis treatment in the Renal Unit of the Churchill Hospital in Oxford. Video was recorded for a total of 84 dialysis sessions from 40 patients during the course of 1 year, comprising an overall video recording time of approximately 304.1 h. Reference values were provided by two devices in regular clinical use. The mean absolute error between the heart rate estimates from the camera and the average from two reference pulse oximeters (positioned at the finger and earlobe) was 2.8 beats/min for over 65% of the time the patient was stable. The mean absolute error between the respiratory rate estimates from the camera and the reference values (computed from the Electrocardiogram and a thoracic expansion sensor—chest belt) was 2.1 breaths/min for over 69% of the time for which the reference signals were valid. To increase the robustness of the algorithms, novel methods were devised for cancelling out aliased frequency components caused by the artificial light sources in the hospital, using auto-regressive modelling and pole cancellation. Maps of the spatial distribution of heart rate and respiratory rate information were developed from the coefficients of the auto-regressive models. Most of the periods for which the camera could not produce a reliable heart rate estimate lasted under 3 min, thus opening the possibility to monitor heart rate continuously in a clinical environment.