30 June 2020 in Applied Optics
We present a performance analysis of compact monolithic optomechanical inertial sensors that describes their key fundamental limits and overall acceleration noise floor. Performance simulations for low-frequency gravity-sensitive inertial sensors show attainable acceleration noise floors on the order of . Furthermore, from our performance models, we devised an optimization approach for our sensor designs, sensitivity, and bandwidth trade space. We conducted characterization measurements of these compact mechanical resonators, demonstrating -products at levels of 250 kg, which highlight their exquisite acceleration sensitivity.
12 August 2020 in Journal of the Optical Society of America A
We have developed an inertially sensitive optomechanical laser by combining a vertical-external-cavity surface-emitting laser (VECSEL) with a monolithic fused silica resonator. By placing the external cavity mirror of the VECSEL onto the optomechanical resonator test mass, we create a sensor where external accelerations are directly transcribed onto the lasing frequency. We developed a proof-of-principle laboratory prototype and observe test mass oscillations at the resonance frequency of the sensor through the VECSEL lasing frequency, . In addition, we set up an ancillary heterodyne interferometer to track the motion of the mechanical oscillator’s test mass, observing a resonance of . The interferometer measurements validate the VECSEL results, confirming the feasibility of using optomechanical lasers for inertial sensing.
2 December 2023 in Applied Optics
Lateral shearing self-referencing interferometry methods shift the surface under test between measurements to separate its topography from that of the reference surface. However, rigid body errors occur during shifting, creating an ambiguity in the quadratic term of the extracted surfaces. We present axial shift mapping, a lateral shearing self-referencing interferometry method for cylinders, in which the quadratic ambiguity is resolved by measuring the rigid body errors using known artifact mirrors residing in the interferometer’s field of view. First, one-dimensional lines of a flat mirror are measured with 2.8 nm RMS difference compared to a three flat test. Then, axial shift mapping is extended to cylindrical surfaces using a computer generated hologram. We find that axial shift mapping results in full surface extraction of cylindrical optics, along the axial direction, with a repeatability of 4.4 nm RMS. We also find that the reference surface extracted through axial shift mapping is within 4.5 nm RMS of the transmitted wavefront error of the computer generated hologram substrate, which was expected to be the largest contribution of reference wavefront error.
2 November 2023 in Applied Optics
A wide variety of systems are employed to measure the surface profile of aspheric and freeform optical surfaces. Freeform metrology systems must accurately characterize the full surface under test, which can be difficult with steep surface slopes. Here we present an interferometric surface metrology probe for highly sloped aspheric and freeform optical surfaces. The optical design of this probe allows the measurement of surface slopes up to 50 deg without tilting the probe, which simplifies stage design and increases the accuracy of the system. A spectrally controlled light source is used to create a virtual ball in front of the probe tip to measure the surface distance and angle. This system produces a cloud of points, to which Zernike polynomials are fit and used to reconstruct the surface. We will show sensitivity tests and accuracy results.