Jan Z. Peruga

Jan Z. Peruga

Auto-generated profile, based on publicly available information

Jan Z. Peruga

Department of Cardiology, Medical University of Lodz, Lodz, Poland

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2008 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
JDJ. Domienik
J. Domienik
SPS. Papierz
S. Papierz
JJJan Jankowski
Jan Jankowski
JPJ. Z. Peruga
J. Z. Peruga
AWA. Werduch
A. Werduch
WRW. Religa
W. Religa
In most countries of European Union, legislation requires the determination of the total skin dose received by patients during interventional procedures in order to prevent deterministic damages. Various dose indicators like dose–area product (DAP), cumulative dose (CD) and entrance dose at the patient plane (EFD) are used for patient dosimetry purposes in clinical practice. This study aimed at relating those dose indicators with doses ascribed to the most irradiated areas of the patient skin usually expressed in terms of local maximal skin dose (MSD). The study was performed in two different facilities for two most common cardiac procedures coronary angiography (CA) and percutaneous coronary interventions (PCI). For CA procedures, the registered values of fluoroscopy time, total DAP and MSD were in the range (0.7–27.3) min, (16–317) Gy cm2 and (43–1507) mGy, respectively, and for interventions, accordingly (2.1–43.6) min, (17–425) Gy cm2, (71–1555) mGy. Moreover, for CA procedures, CD and EFD were in the ranges (295–4689) mGy and (121–1768) mGy and for PCI (267–6524) mGy and (68–2279) mGy, respectively. No general and satisfactory correlation was found for safe estimation of MSD. However, results show that the best dose indicator which might serve for rough, preliminary estimation is DAP value. In the study, the appropriate trigger levels were proposed for both facilities.

16 March 2022 in American Heart Journal
Verified
Journal Article
Closed access
PGPhilippe Généreux
Philippe Généreux
GCGil Chernin
Gil Chernin
AAAbid R. Assali
Abid R. Assali
JPJan Z. Peruga
Jan Z. Peruga
SRSimon D. Robinson
Simon D. Robinson
MJMichael Jonas
Michael Jonas

14 December 2018 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Closed access
PWPaulina Wejner-Mik
Paulina Wejner-Mik
PLPiotr Lipiec
Piotr Lipiec
JPJan Z Peruga
Jan Z Peruga
MMMonika Mozdzan
Monika Mozdzan
Jaroslaw Damian KasprzakJaroslaw Damian Kasprzak
Jaroslaw Damian Kasprzak

31 January 2017 in Nuclear Medicine Review
Verified
Journal Article
Open access
PDF file
KFKrzysztof Filipczak
Krzysztof Filipczak
JKJacek Kuśmierek
Jacek Kuśmierek
JDJaroslaw Drozdz
Jaroslaw Drozdz
KCKrzysztof Chiżyński
Krzysztof Chiżyński
Jaroslaw Damian KasprzakJaroslaw Damian Kasprzak
Jaroslaw Damian Kasprzak
APAnna Płachcińska
Anna Płachcińska
BACKGROUND: The work compares the results of shortened gated myocardial perfusion imaging (MPI), processed with „Myovation Evolution” software, with a study performed in a standard way. MATERIAL AND METHODS: A retrospective study was conducted in a group of 95 patients (56 males and 39 females, age 62 ± 9 years, BMI 28 ± 4) with known or suspected CAD, without clinical history or any signs of a previous myocardial infarction. All patients underwent coronary angiography (CA) within 3 months of MPI. CA was used as a reference for diagnostic performance of MPI. Patients underwent a stress/rest 2-day MPI. Both studies were performed twice, with normal (25s) and shortened (13s) time per projection. Studies were processed using Myovation protocol (OSEM with 2 iterations and 10 subsets) for full time (FT) studies and a Myovation Evolution protocol dedicated to half time (HT) studies (OSEM with 12 iterations, 10 subsets). Reconstructed images, with and without attenuation correction (AC), were evaluated by 2 experienced nuclear medicine specialists (a consensus), with regard to image quality and perfusion, evaluated using a visual semi-quantitative method, applying a standard division of myocardium into 17 segments. Perfusion was assessed in every segment using a standard 5 grade scale. Summed stress scores were calculated for every patient and threshold values for detection of CAD were selected based on ROC analysis with CA treated as a reference method. After 2 months FT images were interpreted again by the same specialists. RESULTS: The quality of images obtained from shortened and normal studies was equally good. All correlation coefficients between segmental scorings of FT and HT studies were high and statistically significant. Correlation coefficients between corresponding segments in FTAC and HTAC (i.e. with AC) studies were systematically higher than without AC. The agreement between FT and HT study results was equal to 81% for FT and HT studies and to 86% for FTAC and HTAC studies (p = 0.40). The repeatability of FTAC study assessments was equal to 94%. 95-percent confidence intervals calculated for agreement between FTAC and HTAC studies and the repeatability of FTAC study overlapped considerably. Correlation coefficients for EDV, ESV and EF values between FT and HT were high: 0.93, 0.96 and 0.88, respectively. CONCLUSION: Myovation Evolution protocol used for reconstruction of myocardial perfusion studies with reduced number of counts requires AC. The agreement between the results of visual assessment of normal and reduced count studies is high and not worse than the agreement between repeat assessment of a full time study. BACKGROUND: The work compares the results of shortened gated myocardial perfusion imaging (MPI), processed with „Myovation Evolution” software, with a study performed in a standard way. MATERIAL AND METHODS: A retrospective study was conducted in a group of 95 patients (56 males and 39 females, age 62 ± 9 years, BMI 28 ± 4) with known or suspected CAD, without clinical history or any signs of a previous myocardial infarction. All patients underwent coronary angiography (CA) within 3 months of MPI. CA was used as a reference for diagnostic performance of MPI. Patients underwent a stress/rest 2-day MPI. Both studies were performed twice, with normal (25s) and shortened (13s) time per projection. Studies were processed using Myovation protocol (OSEM with 2 iterations and 10 subsets) for full time (FT) studies and a Myovation Evolution protocol dedicated to half time (HT) studies (OSEM with 12 iterations, 10 subsets). Reconstructed images, with and without attenuation correction (AC), were evaluated by 2 experienced nuclear medicine specialists (a consensus), with regard to image quality and perfusion, evaluated using a visual semi-quantitative method, applying a standard division of myocardium into 17 segments. Perfusion was assessed in every segment using a standard 5 grade scale. Summed stress scores were calculated for every patient and threshold values for detection of CAD were selected based on ROC analysis with CA treated as a reference method. After 2 months FT images were interpreted again by the same specialists. RESULTS: The quality of images obtained from shortened and normal studies was equally good. All correlation coefficients between segmental scorings of FT and HT studies were high and statistically significant. Correlation coefficients between corresponding segments in FTAC and HTAC (i.e. with AC) studies were systematically higher than without AC. The agreement between FT and HT study results was equal to 81% for FT and HT studies and to 86% for FTAC and HTAC studies (p = 0.40). The repeatability of FTAC study assessments was equal to 94%. 95-percent confidence intervals calculated for agreement between FTAC and HTAC studies and the repeatability of FTAC study overlapped considerably. Correlation coefficients for EDV, ESV and EF values between FT and HT were high: 0.93, 0.96 and 0.88, respectively. CONCLUSION: Myovation Evolution protocol used for reconstruction of myocardial perfusion studies with reduced number of counts requires AC. The agreement between the results of visual assessment of normal and reduced count studies is high and not worse than the agreement between repeat assessment of a full time study.