29 July 2020 in IEEE Systems Journal
This article solves the problem of accurate detection of internal faults and classification of transients in a five-bus interconnected system for phase angle regulators (PARs) and power transformers (PTs). The analysis prevents mal-operation of differential relays in case of transients other than faults, which include magnetizing inrush, sympathetic inrush, external faults with current transformer (CT) saturation, capacitor switching, nonlinear load switching, and ferroresonance. A gradient boosting classifier (GBC) is used to distinguish the internal faults from the transient disturbances based on 1.5 cycles of three-phase differential currents registered by a change detector. After the detection of an internal fault, GBCs are used to locate the faulty unit (PT, PAR series, or exciting unit) and identify the type of fault. In case, a transient disturbance is detected, another GBC classifies them into the six disturbances. Five most relevant frequency- and time-domain features obtained using information gain are used to train and test the classifiers. The proposed algorithm distinguishes the internal faults from the other transients with a balanced accuracy ( $\bar{\eta }$ ) of 99.95%. The faulty transformer unit is located with $\bar{\eta }$ of 99.5% and the different transient disturbances are identified with $\bar{\eta }$ of 99.3%. Moreover, the reliability of the scheme is verified for different ratings and connections of the transformers involved, CT saturation, and noise levels in the signals. These GBC classifiers can work together with a conventional differential relay and offer a supervisory control over its operation. PSCAD/EMTDC software is used for simulation of the transients and to develop the two- and three-winding transformer models for creating the internal faults including interturn and interwinding faults.
17 May 2021 in IEEE Access
Several conventional and non-conventional transient conditions cause differential relays associated with Phase Angle Regulators to malfunction. For Two-core Symmetric Phase Angle Regulators, this article investigates the suitability of time and time-frequency feature-based estimators to differentiate internal faults from other transient conditions such as overexcitation, external faults with current transformer (CT) saturation, and magnetizing inrush. Subsequently, the faulty core unit (series or exciting) is located, and the transients are identified. Six well-known classifiers are trained on features extracted from one-cycle of post transient 3-phase differential currents filtered by an event detector. Maximum Relevance Minimum Redundancy, Random Forest, and exhaustive search with Decision Trees are used to select the relevant wavelet energy, time-domain, and wavelet coefficient features respectively. The fault detection scheme trained on XGBoost classifier with hyperparameters obtained from Bayesian Optimization gives an accuracy of 99.8%. The reliability of the proposed scheme is verified with varying tap positions, noise levels, and transformer ratings; and under different conditions like CT saturation, fault during magnetizing inrush, series core saturation, low current faults, and integration of wind energy. As a potential application, the methodology can be deployed to supervise microprocessor-based differential relays to improve the security and dependability of the protection system.