Pidassa Bidola

Pidassa Bidola

Auto-generated profile, based on publicly available information

Pidassa Bidola

Institute of Materials Physics, Helmholtz-Zentrum Hereon, Max-Planck-Straße 1, 21502 Geesthacht, Germany

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2018 in APL Bioengineering
Verified
Journal Article
Open access
PDF file
LHLorenz Hehn
Lorenz Hehn
KMKaye Morgan
Kaye Morgan
PBPidassa Bidola
Pidassa Bidola
WNWolfgang Noichl
Wolfgang Noichl
RGRegine Gradl
Regine Gradl
FPFranz Pfeiffer
Franz Pfeiffer
Propagation-based phase-contrast tomography has become a valuable tool for visualization of three-dimensional biological samples, due to its high sensitivity and its potential in providing increased contrast between materials with similar absorption properties. We present a statistical iterative reconstruction algorithm for this imaging technique in the near-field regime. Under the assumption of a single material, the propagation of the x-ray wavefield—relying on the transport-of-intensity equation—is made an integral part of the tomographic reconstruction problem. With a statistical approach acting directly on the measured intensities, we find an unconstrained nonlinear optimization formulation whose solution yields the three-dimensional distribution of the sample. This formulation not only omits the intermediate step of retrieving the projected thicknesses but also takes the statistical properties of the measurements into account and incorporates prior knowledge about the sample in the form of regularization techniques. We show some advantages of this integrated approach compared to two-step approaches on data obtained using a commercially available x-ray micro-tomography system. In particular, we address one of the most considerable challenges of the imaging technique, namely, the artifacts arising from samples containing highly absorbing features. With the use of statistical weights in our noise model, we can account for these materials and recover features in the vicinity of the highly absorbing features that are lost in the conventional two-step approaches. In addition, the statistical modeling of our reconstruction approach will prove particularly beneficial in the ongoing transition of this imaging technique from synchrotron facilities to laboratory setups.

1 December 2023 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
HKHans-Henrik König
Hans-Henrik König
NSNick Semjatov
Nick Semjatov
GSGabriel Spartacus
Gabriel Spartacus
PBPidassa Bidola
Pidassa Bidola
CIChrysoula Ioannidou
Chrysoula Ioannidou
GLGreta Lindwall
Greta Lindwall
The development of a sample environment for in situ x-ray characterization during metal Electron Beam Powder Bed Fusion (PBF-EB), called MiniMelt, is presented. The design considerations, the features of the equipment, and its implementation at the synchrotron facility PETRA III at Deutsches Elektronen-Synchrotron, Hamburg, Germany, are described. The equipment is based on the commercially available Freemelt ONE PBF-EB system but has been customized with a unique process chamber to enable real-time synchrotron measurements during the additive manufacturing process. Furthermore, a new unconfined powder bed design to replicate the conditions of the full-scale PBF-EB process is introduced. The first radiography (15 kHz) and diffraction (1 kHz) measurements of PBF-EB with a hot-work tool steel and a Ni-base superalloy, as well as bulk metal melting with the CMSX-4 alloy, using the sample environment are presented. MiniMelt enables time-resolved investigations of the dynamic phenomena taking place during multi-layer PBF-EB, facilitating process understanding and development of advanced process strategies and materials for PBF-EB.

26 August 2025 in Additive Manufacturing
Verified
Journal Article
Open access
NSNick Semjatov
Nick Semjatov
HKHans-Henrik König
Hans-Henrik König
PBPidassa M. Bidola
Pidassa M. Bidola
GAGuilherme Abreu-Faria
Guilherme Abreu-Faria
BWBenjamin Wahlmann
Benjamin Wahlmann
CKCarolin Körner
Carolin Körner

1 January 2026 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PBPidassa Bidola
Pidassa Bidola
NSNick Semjatov
Nick Semjatov
GSGabriel Spartacus
Gabriel Spartacus
HKHans-Henrik König
Hans-Henrik König
GAGuilherme Abreu-Faria
Guilherme Abreu-Faria
FBFelix Beckmann
Felix Beckmann
A high-speed synchrotron radiography system has been developed to facilitate in situ imaging of dynamic processes in electron beam powder bed fusion (PBF-EB). Using the P61A White Beam Engineering Materials Science beamline at PETRA III, this system achieves high temporal resolution and a spatial resolution of approximately 10 µm. The scintillator screens are coupled to a diamond plate and housed within a specialized nitrogen gas cooling system, effectively mitigating thermal stress caused by the intense synchrotron beam. These innovative components ensure stable imaging performance and enhance the system's ability to operate under extreme conditions. By resolving fringes at short propagation distances for the partially coherent beam, the imaging system has enabled the efficient visualization of crack formation and pore evolution in high- Z materials, such as nickel-based superalloys, during the PBF-EB process. These advances not only optimize imaging in extreme environments but also open new avenues for high-energy synchrotron applications, including dynamic phase imaging and laser welding studies of dense samples.