Declan P. McCarthy

Declan P. McCarthy

Auto-generated profile, based on publicly available information

Declan P. McCarthy

The Molecular Foundry and Materials Science Division, Lawrence Berkeley National Laboratory, Berkeley, USA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2019 in Journal of Chromatography B
Verified
Journal Article
Open access
DBDeepak Bhandari
Deepak Bhandari
DMDeclan McCarthy
Declan McCarthy
CBChloe Biren
Chloe Biren
CMCameron Movassaghi
Cameron Movassaghi
BBBenjamin C Blount
Benjamin C Blount
VJVictor De Jesus
Victor De Jesus
We report on the development of an ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for simultaneously measuring eight biomarkers of volatile organic compound (VOC) exposure, with potential application to e-cigarette aerosol biomonitoring. Phenylmercapturic acid (PMA) and trans, trans-muconic acid (tt-MA) are metabolites of benzene; 2-aminothiazoline-4-carboxylic acid (ATCA) is a metabolite of cyanide; N-2-furoylglycine (N2FG) is a metabolite of furfural and furfuryl alcohol; 5-hydroxymethylfuroic acid (HMFA), 5-hydroxymethyl-2-furoylglycine (HMFG), and 2,5-furandicarboxylic acid (FDCA) are metabolites of 5-hydroxymethylfurfural; and 5-hydroxy-N-methylpyrrolidone (5HMP) is a metabolite of N-methyl-2-pyrrolidone. A pentafluorophenyl-modified silica column was used for chromatographic separation. The overall run time for the method is about 6 min per sample injection. The method has low to sub-nanograms per milliliter sensitivity, linearity over 3 orders of magnitude, and precision and accuracy within 15%. The method was used to measure human urine samples. Results showed that people with known benzene exposure (daily cigarette smokers) had higher levels of tt-MA and PMA compared with non-smokers. The method is advantageous for high-throughput analysis of selected VOC metabolites in large-scale, population-based studies such as the National Health and Nutrition Examination Survey (NHANES). Quantifying these urinary biomarkers is important to public health efforts to understand human exposure to VOCs from various sources, including tobacco products and electronic nicotine delivery systems.

5 November 2020 in Materials Chemistry Frontiers
Verified
Journal Article
Closed access
PDF file
KKKhaled Al Kurdi
Khaled Al Kurdi
DMDeclan P. McCarthy
Declan P. McCarthy
DMDavid P. McMeekin
David P. McMeekin
SFSebastian O. Furer
Sebastian O. Furer
MTMarie-Hélène Tremblay
Marie-Hélène Tremblay
SMSeth Marder
Seth Marder
Poly(N-(5-(5-norbornene-2-carbonyl)oxy)pentyl)-N′-n-hexyl-naphthalene-1,8:4,5-bis(dicarboximide) has been synthesized by esterification of (N-(5-hydroxypentyl)-N′-n-hexyl-naphthalene-1,8:4,5-bis(dicarboximide)) with exo-5-norbornene-2-carboxylic acid, and has been polymerized using the first-generation Grubbs initiator. This side-chain polymer exhibits good transparency throughout the visible (absorption onset at ca. 400 nm), good solubility in common low- and medium-polarity organic solvents, good resistance to dimethylformamide, and appropriate electron affinity for use as an electron-extraction layer in lead-halide perovskite solar cells. The performance of this polymer in n-i-p perovskite solar cells was compared to that of several small-molecule naphthalene-1,8:4,5-bis(dicarboximide) derivatives and of SnO2. Solar cells using the polymer exhibited open-circuit voltages of up to 1.02 V, short-circuit currents of over 21 mA cm−2, and power conversion efficiencies (PCE) reaching 14% which stabilize at 13.8% upon 90 s of illumination. Meanwhile control SnO2 devices exhibited a PCE of ca. 16%, and small-molecule devices gave PCE values of less than 10%. The devices employing the polymer exhibited improved long-term stability relative to the SnO2 control devices under continuous illumination.

17 June 2025 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
MTMargherita Taddei
Margherita Taddei
HCHannah Contreras
Hannah Contreras
HDHai-Nam Doan
Hai-Nam Doan
DMDeclan P. McCarthy
Declan P. McCarthy
SSSeongrok Seo
Seongrok Seo
DGDavid S. Ginger
David S. Ginger

22 April 2019 in Journal of the American Society for Mass Spectrometry
Verified
Journal Article
Closed access
CMCameron S. Movassaghi
Cameron S. Movassaghi
DMDeclan P. McCarthy
Declan P. McCarthy
DBDeepak Bhandari
Deepak Bhandari
BBBenjamin C. Blount
Benjamin C. Blount
VJVíctor R. De Jesús
Víctor R. De Jesús

20 December 2023 in Chemical Communications
Verified
Journal Article
Closed access
PDF file
AMAiswarya Abhisek Mohapatra
Aiswarya Abhisek Mohapatra
WYWaleed Kuar Yual
Waleed Kuar Yual
YZYadong Zhang
Yadong Zhang
ASAnton Aleksandrovich Samoylov
Anton Aleksandrovich Samoylov
JTJonathan Thurston
Jonathan Thurston
SMSeth Marder
Seth Marder
An azide-modified phosphonic acid can be used to covalently tether polymers to indium tin oxide, preventing delamination and dissolution.

13 October 2026 in Nature
Verified
Journal Article
Closed access
PDF file
CWCristian P. Woroch
Cristian P. Woroch
LKLiana Klivansky
Liana Klivansky
DMDeclan P. McCarthy
Declan P. McCarthy
HMHeidi Miao
Heidi Miao
ZFZachary Fink
Zachary Fink
JHJohn F. Hartwig
John F. Hartwig