Dong Liu

Dong Liu

Auto-generated profile, based on publicly available information

Dong Liu

Purple Mountain Observatory, Nanjing, Jiangsu China 210008

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2018 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
ZWZheng Wang
Zheng Wang
WZWen Zhang
Wen Zhang
WMWei Miao
Wei Miao
DLDong Liu
Dong Liu
JZJia-Qiang Zhong
Jia-Qiang Zhong
SSSheng-Cai Shi
Sheng-Cai Shi
Superconducting titanium thin films are good candidates for transition edge sensors. In this paper, we deposit titanium thin films on cooled silicon-on-insulator substrates by using electron-beam evaporation. The deposition rate dependence of the film stress, resistivity and superconducting transition temperature are presented and analyzed. The relationship between film electrical properties and thickness is discussed. For investigating the heating influence on thin Ti films, a depth profile of oxygen diffusion in the films is also analyzed by X-ray photoelectron spectroscopy.

3 January 2020 in IEEE Transactions on Terahertz Science and Technology
Verified
Journal Article
Closed access
HZHaotian Zhu
Haotian Zhu
DLDong Liu
Dong Liu
JHJie Hu
Jie Hu
SLSheng Li
Sheng Li
SSSheng-Cai Shi
Sheng-Cai Shi
WCWenquan Che
Wenquan Che

31 December 2021 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
JHJie Hu
Jie Hu
WLWei-Tao Lv
Wei-Tao Lv
HZHaotian Zhu
Haotian Zhu
ZLZheng Lou
Zheng Lou
DLDong Liu
Dong Liu
SSSheng-Cai Shi
Sheng-Cai Shi
Platelets corrugated horn is a promising technology for their scalability to a large corrugated horn array. In this paper, we present the design, fabrication, measurement and uncertainty analysis of a wideband 170-320 GHz platelet corrugated horn that features with low sidelobe across the band (< -30 dB). We also propose an accurate and universal method to analyze the axial misalignment of the platelets for the first time. It is based on the mode matching (MM) method with a closed-form solution to off-axis circular waveguide discontinuities obtained by using Graf addition theorem for the Bessel functions. The uncertainties introduced in the fabrication have been quantitatively analyzed using the Monte Carlo method. The analysis shows the cross-polarization of the corrugated horn degrades significantly with the axial misalignment. It well explains the discrepancy between the designed and the measured cross-polarization of platelets corrugated horn fabricated in THz band. The method can be used to determine the fabrication tolerance needed for other THz corrugated horns and evaluate the impact of the corrugated horn for astronomical observations.

21 February 2019 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
JZJiaQiang Zhong
JiaQiang Zhong
WZWen Zhang
Wen Zhang
WMWei Miao
Wei Miao
DLDong Liu
Dong Liu
ZWZheng Wang
Zheng Wang
FPFrancois Pajot
Francois Pajot
High time resolution optical/Infrared (IR) astronomy will require fast response detectors. In order to meet such requirement, cryogenic optical/IR detectors, such as superconducting tunnel junctions (STJ) and transition-edge sensors (TES), are under development. Of these cryogenic detectors, superconducting titanium (Ti) bolometric detectors, with a transition temperature of around 300 mK, based on the electron-phonon decoupling mechanism, is promising in fast response. In this paper, we report on the characterization of electro-thermal properties of a small-size (1 μm × 1 μm × 37 nm) superconducting Ti detector. The low frequency noise of Ti film was fitted by empirical Hooge model. A discrepancy between the Hooge constant of the Ti film and that of normal metals shows disorder in the Ti film. Thermal conductance was extracted via measured current-voltage curves at different bath temperatures. The time constant was calculated as tens of nanoseconds, which was faster than expected. The fast response potentially enables the high speed optical/IR astronomical observations. Detailed experimental and analytical results are presented.

9 January 2026 in Science Advances
Verified
Journal Article
Open access
YGYan Gong
Yan Gong
JZJiaqiang Zhong
Jiaqiang Zhong
YRYuan Ren
Yuan Ren
YZYilong Zhang
Yilong Zhang
DLDaizhong Liu
Daizhong Liu
JLJing Li
Jing Li
The cycling of carbon between its ionized, atomic, and molecular phases shapes the chemical compositions and physical conditions of the interstellar medium (ISM). However, ground-based studies of the full carbon cycle have been limited by atmospheric absorption. Dome A, the most promising site for submillimeter astronomy, has long resisted successful submillimeter astronomical observations. Using the 60-centimeter Antarctic Terahertz Explorer, we present the first successful CO (4-3) and [CI] ( P 1 3 − P 0 3 ) mapping observations of two archetypal triggered massive star-formation regions at Dome A. These data, together with archival [CII], provide the first complete characterization of all three carbon phases in these environments. We find elevated C 0 /CO abundance ratios in high-extinction regions, plausibly driven by deep penetration of intense radiation fields from massive stars into a clumpy ISM. These findings mark a major milestone for submillimeter astronomy at Dome A and offer valuable insights into the impact of massive star feedback on the surrounding ISM.

10 March 2026 in IEEE Microwave and Wireless Technology Letters
Verified
Journal Article
Closed access
DLDong Liu
Dong Liu
YFYu-Min Fan
Yu-Min Fan
Jiang-Qiao DingJiang-Qiao Ding
Jiang-Qiao Ding
SSSheng-Cai Shi
Sheng-Cai Shi
A terahertz (THz) waveguide directional coupler with weak coupling based on a single quartz chip is proposed in this letter. Three radial microstrip probes are adopted to offer a weak coupling, meanwhile corrugated structures are used to prevent the crosstalk between probes. Both probes and decoupling circuits have been integrated on the single quartz chip to replace the un-machinable waveguide branches in a traditional weak coupler. Besides, the angle and radius of each radial probe can be adjusted to obtain different coupling coefficients. Two quartz chip prototypes with different coupling coefficients of −20 and −17 dB have been produced and mounted in the WR-3.4 waveguide blocks. The measured coupling coefficients are $-18$ ±2 dB and $-15$ ±2 dB, respectively, which agree well with the simulation across the wideband of 200–290 GHz. This exploitation of a single quartz chip with adjustable coupling has exemplified the innovation of weak coupler design, which can meet the application requirements of THz sideband-separating receivers.