Maximilien Glorieux

Maximilien Glorieux

Auto-generated profile, based on publicly available information

Maximilien Glorieux

IROC Technologies, Grenoble, France

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2016 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
RLRui Liu
Rui Liu
VFVeronique Ferlet-Cavrois
Veronique Ferlet-Cavrois
AEAdrian Evans
Adrian Evans
LCLi Chen
Li Chen
YLYuanqing Li
Yuanqing Li
LSLeopold Summerer
Leopold Summerer
Measuring single-event transient (SET) pulse widths is critical for developing proper mitigation schemes to single-event effects (SEE), especially for advanced technologies. This paper presents a test chip design implementing advanced techniques for measuring SETs implemented in a 28 nm Ultra-Thin Body and Box (UTBB) FDSOI technology. Experimental results of heavy ion and Co-60 irradiation experiments are presented. The heavy ion experiments confirm that this technology has very low SEE sensitivity. Laser test results show that pulse distortion (broadening) plays a key role when evaluating the effect of SETs. Total Ionizing Dose (TID) effects were also evaluated by measuring the Ring Oscillator (RO) frequencies and static current during heavy ion and Co-60 irradiation. Experimental results showed that the RO frequencies degraded up to 10% (heavy ion), and 40% (Co-60) after 1000 krad(Si) irradiation, but the logic in the chip functioned without error.

6 November 2014 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
MGM. Glorieux
M. Glorieux
JAJean-Luc Autran
Jean-Luc Autran
DMDaniela Munteanu
Daniela Munteanu
SCS. Clerc
S. Clerc
GGG. Gasiot
G. Gasiot
PRP. Roche
P. Roche
A new computational model for charge transport based on parallelized random-walk drift-diffusion is proposed. This approach models the radiation-induced charge carriers as charge packets in a 3-D structure and the transport modeling are based on simple physical equations without any fitting parameter. This model has been dynamically coupled with a SPICE circuit simulator to take into account temporal variations of the electric fields in the charge collection process. Thus, the circuit electrical response modulates the charge collection efficiency. Three simulation cases have been explored and compared with TCAD simulations or radiation experiments in 65 nm technology to validate the accuracy of the proposed approach. These simulations demonstrate the capability of the proposed model to accurately estimate the soft error rate of complex structures, such as flip-flops over a large range of ionizing particle linear energy transfer. The proposed simulation methodology is also able to take into account charge-sharing phenomenon, and this point is highlighted by a specific investigation on the considered flip-flop.

4 November 2019 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Open access
RARuben Garcia Alia
Ruben Garcia Alia
MTMaris Tali
Maris Tali
MBMarkus Brugger
Markus Brugger
MCMatteo Cecchetto
Matteo Cecchetto
FCFrancesco Cerutti
Francesco Cerutti
HPHelmut Puchner
Helmut Puchner
We investigate, through measurements and simulations, the possible direct ionization impact in the accelerator soft error rate, not considered in standard qualification approaches. Results show that, for a broad variety of state-of-the art commercial components considered in the 65 nm to 16 nm technological range, indirect ionization is still expected to dominate the overall soft-error rate in the accelerator mixed-field. However, the derived critical charges of the most sensitive parts, corresponding to ∼0.7 fC, are expected to be at the limit of rapid direct ionization dominance and soft-error increase.

1 July 2019
Verified
Conference Paper
Open access
TLThomas Lange
Thomas Lange
ABAneesh Balakrishnan
Aneesh Balakrishnan
MGMaximilien Glorieux
Maximilien Glorieux
DADan Alexandrescu
Dan Alexandrescu
LSLuca Sterpone
Luca Sterpone
The Functional Failure Rate analysis of today’s complex circuits is a difficult task and requires a significant investment in terms of human efforts, processing resources and tool licenses. Thereby, de-rating or vulnerability factors are a major instrument of failure analysis efforts. Usually computationally intensive fault-injection simulation campaigns are required to obtain a fine-grained reliability metrics for the functional level. Therefore, the use of machine learning algorithms to assist this procedure and thus, optimising and enhancing fault injection efforts, is investigated in this paper. Specifically, machine learning models are used to predict accurate per-instance Functional De-Rating data for the full list of circuit instances, an objective that is difficult to reach using classical methods. The described methodology uses a set of per-instance features, extracted through an analysis approach, combining static elements (cell properties, circuit structure, synthesis attributes) and dynamic elements (signal activity). Reference data is obtained through first-principles fault simulation approaches. One part of this reference dataset is used to train the machine learning model and the remaining is used to validate and benchmark the accuracy of the trained tool. The presented methodology is applied on a practical example and various machine learning models are evaluated and compared.

10 January 2024 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
Laurent ArtolaLaurent Artola
Laurent Artola
MGM. Glorieux
M. Glorieux
GHG. Hubert
G. Hubert
CIC. Inguimbert
C. Inguimbert
TBT. Bonnoit
T. Bonnoit
CPC. Poivey
C. Poivey
This work presents the SEU responses of four SRAM devices (65nm, 40nm, 28nm and 16nm) measured at different angles of incidence and orientation of the device in respect to the low energy proton beam direction. Experimental data are discussed with the support of multi-physics and multi-scale simulations. Difference of one order of magnitude is observed for SRAMs irradiated between the different directions the beam is entering the device. The conclusions drawn from the simulation results suggesting that the difference in the SEU cross section could be attributed to the charge sharing between the N and P wells of the two inverters of the SRAM bit. The consequent feedback reduces the overall ionization effects in the SRAM cell when exposed to low energy protons.

7 May 2024 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
MGMaximilien Glorieux
Maximilien Glorieux
TBThierry Bonnoit
Thierry Bonnoit
TLThomas Lange
Thomas Lange
RGRemi Gaillard
Remi Gaillard
INIssam Nofal
Issam Nofal
CPCesar Boatella Polo
Cesar Boatella Polo
In space environments, protons can cause single event effects either by direct ionization or by nuclear reactions whose secondary products deposit charges in sensitive regions. Given the low linear energy transfer value of proton, the direct ionization contribution was usually considered negligible in technologies larger than 65 nm. However, as a result of the technology scaling and the voltage reduction, the minimum amount of charge required to invert the state of a memory cell has significantly decreased. and direct ionization mechanism can even dominate the low earth orbit error rates, in some specific conditions. Proton direct ionization occurs only at very low energies, near the ionization Bragg peak. Therefore, its experimental characterization requires specific beam characteristics and the corresponding methods to evaluate the orbital upset rates. This work proposes two methodologies to characterize the sensitivity of SRAM devices to proton direct ionization and details the procedures for orbital error rates calculation. Both approaches were applied to a set of four SRAM devices, ranging from 65 nm down to 16 nm FinFET and the resulting upset rates were cross-validated to evaluate their accuracy. The respective advantages and limitations of each methodology are discussed, taking into account the specific constraints related to the test facilities and the device under test.