Irumee Pai

Irumee Pai

Auto-generated profile, based on publicly available information

Irumee Pai

School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2020 in Clinical Otolaryngology
Verified
Journal Article
Closed access
PDF file
NANikul Amin
Nikul Amin
ASAndrew Jonathan Soulby
Andrew Jonathan Soulby
Daniele BorsettoDaniele Borsetto
Daniele Borsetto
IPIrumee Pai
Irumee Pai

26 September 2024 in The Journal of International Advanced Otology
Verified
Journal Article
Open access
EKEmma Keane
Emma Keane
EBEishaan Bharghava
Eishaan Bharghava
MCMichiel Claerhout
Michiel Claerhout
BMBenjamin Miller
Benjamin Miller
IPIrumee Pai
Irumee Pai
DJDan Jiang
Dan Jiang
Background: Since its introduction by Wullstein, the binocular surgical microscope has remained the gold standard of visualization in the field of otology. However, in the last decade, new technology became available in the form of the three-dimensional (3D) exoscope. In this article, we describe our experience thus far in pediatric cochlear implantation with the 3D exoscope. Methods: This article is about prospective descriptive study of all exoscopic cochlear implant (CI) cases in a quaternary pediatric CI center performed with the Vitom® 3D system. All pediatric patients (age <18) were included without exclusion criteria, and our experience and conversion to microscope rates are reported. Results: Since the introduction of the exoscope to our unit, we have successfully performed 68 cases, of which 53 were bilateral cochlear implantations. The age of the patient varied between 10 months and 209 months (average: 64 months; median 46.5 months). There were a total of 121 implantations (96 primary implantations, 24 revision implantations). There were 2 conversions to the traditional microscopic technique. Conclusion: The exoscope provides a 3D high-definition (4K) images in CI surgery. There is limited data regarding its use, and we identified a number of advantages including efficiency, occupational health, theater utilization, surgical training, and safety. Although there are areas still for improvement, such as loss of signal-to-noise ratio at higher magnification, manual focus, and lack of electromagnetic articulation in the holding arm, we have found it to be a useful addition to the surgical armamentarium within pediatric cochlear implantation. Cite this article as: Keane E, Bharghava E, Claerhout M, et al. New frontiers in pediatric cochlear implant surgery – A single center experience with the 3-dimensional exoscope. J Int Adv Otol. 2024;20(5):379-382.

24 September 2020 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
EAE. Ainsworth
E. Ainsworth
IPI. Pai
I. Pai
MKM. Kathirgamanathan
M. Kathirgamanathan
SCS.E.J. Connor
S.E.J. Connor
BACKGROUND AND PURPOSE: Otalgia may be secondary to serious pathology, such as upper aerodigestive tract malignancies, and CT or MR imaging of the skull base, face, and neck is often performed to detect clinically occult lesions. The diagnostic yield, management impact, and therapeutic impact of imaging in this clinical scenario, however, have yet to be elucidated. MATERIALS AND METHODS: CT and MR imaging in patients who presented with otalgia without clinically overt disease was retrospectively analyzed from a single center over a 9-year period. The cohort was subdivided into groups, depending on the presence of additional symptoms and a history of head and neck cancer. Relevant diagnostic outcome findings were categorized, and the diagnostic yield and impact of imaging on management and therapy were calculated for each group. RESULTS: In our study cohort of 235 patients, the diagnostic yield of imaging for otalgia, with or without other symptoms, in patients who lacked a history of head and neck cancer was negligible for upper aerodigestive tract malignancy (1%), abnormalities related to otalgia (2%), and other moderate or major findings (2%). Although equivocal or unimportant findings occasionally resulted in additional investigations, the therapeutic impact was also very low (2%). The diagnostic yield for upper aerodigestive tract malignancy (34%) and therapeutic impact increased (34%) when there was a history of head and neck cancer. CONCLUSIONS: The diagnostic yield and therapeutic impact of imaging for otalgia without clinically overt disease are very low, unless there is a history of head and neck cancer.

30 November 2025 in Clinical and Experimental Otorhinolaryngology
Verified
Journal Article
Open access
PDF file
IPIrumee Pai
Irumee Pai
ASAditi Shetty
Aditi Shetty
GPGowri Pradeep
Gowri Pradeep
CKCharalampos Komninos
Charalampos Komninos
CBChristos Bergeles
Christos Bergeles
SCSteve Connor
Steve Connor
Objectives. The primary objective was to determine which of the following angular insertion depth (AID) estimation methods showed the strongest correlation with the postoperative AID (AIDpostop) of a lateral wall (LW) electrode: the Escudé formula, based on the largest distance from the round window (RW) to the LW (distance A); the elliptic-circular approximation (ECA) method, based on both distance A and the perpendicular distance (distance B); and a three-dimensional (3D) reconstruction method. The secondary objective was to assess the impact of using the actual electrode insertion length on the evaluation of AID estimation methods.Methods. This study included 45 cochleae implanted with the Advanced Bionics SlimJ electrode, with all 16 active electrode contacts positioned intracochlear. Distance A, distance B, and a 3D reconstruction along the LW were evaluated on preoperative magnetic resonance imaging using 3D Slicer. The AIDpostop and insertion length were assessed using cone-beam computed tomography. Two sets of estimated AID values were obtained: assuming a perfect 23-mm insertion length with the reference electrode at the RW (AID23mm); and using the actual insertion length (AIDinsertionlength). Spearman’s rank correlation coefficient was used to assess the association between the estimated AID values and AIDpostop.Results. A moderately positive correlation was observed between AID23mm and AIDpostop for all three approaches, with no statistically significant differences among them (rs=0.410–0.579). When the analysis was repeated using AIDinsertionlength, the strength of the correlation with AIDpostop increased significantly for all three methods, with the 3D reconstruction method showing a stronger correlation (rs=0.952) than the Escudé formula (rs=0.734) or the ECA method (rs=0.787) (P<0.001).Conclusion. The 3D reconstruction approach has the potential to improve prediction of the AID for LW electrode arrays compared to spiral formulae based on 2D cochlear dimensions. Accurate assessment of the actual insertion length is important for the proper evaluation of AID estimation methods.

7 August 2026 in European Archives of Oto-Rhino-Laryngology
Verified
Journal Article
Open access
IPIrumee Pai
Irumee Pai
PRPaolo Rondi
Paolo Rondi
IMIsobel Morley
Isobel Morley
EHEmily Hocknell
Emily Hocknell
AHAndrew Hoey
Andrew Hoey
RRRithvik Reddy
Rithvik Reddy
Purpose: This retrospective study systematically compared scalar position characteristics and translocation (STL) rates within the cochlear basal turn (CBT) across three different lateral wall (LW) electrodes. Methods: The study included 148 morphologically normal cochleae implanted with Advanced Bionics SlimJ (ABSJ, n = 51), Cochlear Slim Straight (CSS, n = 51), or MED-EL FLEX (MFX, n = 46). Cochlear dimensions (distances A and B) and angular insertion depth (AID) were measured by two observers. Scalar position was assessed on postoperative cone-beam CT at 90°, 180°, 270°, and 360° by three observers using a five-point scale (1–2 = scala vestibuli (SV), 3 = central, 4–5 = scala tympani (ST)). Results: Distances A and B were comparable across groups ( p > .05). Mean AID was significantly greater for MFX ( p < .001). MFX had higher median scalar scores than CSS at every angle (all Bonferroni-adjusted p < .001) and than ABSJ at 180°, 270°, and 360° (adjusted p < .001). ST retention (all four median scores ≥ 3) was observed in 92.2% of ABSJ, 78.4% of CSS, and 100% of MFX cases, while STL (median score decreased to 1–2 and remained ≤ 3) occurred in 7.8%, 15.7%, and 0%, respectively. MFX demonstrated significantly lower STL and higher ST retention rates than CSS (adjusted p = .018 and p < .003, respectively). No independent associations of distance A, distance B, or AID with either STL or ST retention were identified (all p ≥ .54). Conclusion: Significant differences in scalar position and STL rates were observed among LW electrodes, with MFX showing the most stable ST placement.

5 November 2019 in The Journal of Laryngology & Otology
Verified
Journal Article
Open access
PDF file
IPIrumee Pai
Irumee Pai
ECElfy B Chevretton
Elfy B Chevretton
SHSherif Haikel
Sherif Haikel
ASAnn Sandison
Ann Sandison
SCSteve Connor
Steve Connor
ASAta Siddiqui
Ata Siddiqui
The Professor Leslie Michaels prize for the best presentation of the meeting was awarded jointly to Rebecca Harrison for 'Maintaining your index of suspicion in unexplained facial palsy' and Guled Jama for 'An unexpected cause