This paper proposes an improved finite-set model predictive control (FS-MPC) to reduce current ripples and balance the neutral-point voltage for grid-connected three-level voltage source inverter. The proposed FS model predictive current control is based on the discrete space vector modulation (DSVM) to synthesize various voltage vectors. The proposed DSVM method enables to calculate all of the virtual voltage vector values immediately without the lookup table. To overcome the excessive computation burden problem, the optimal region determination strategy is presented in order to use only minimum number of voltage vectors for the cost function calculation. To balance the neutral-point voltage, the proposed offset voltage injection (OVI) method based on the FS-MPC is introduced in this paper. Various offset voltage values are obtained and an optimal offset voltage value is determined using the MPC algorithm. Since the proposed control method is based on space vector diagram without being restricted by the switching states, it can be easily applied to a multilevel system or other applications. The simulation and experiment results are presented to validate the effectiveness and performance of the proposed method using the grid-connected three-level T-type voltage source inverter.
22 March 2017 in IEEE Transactions on Industrial Electronics
This paper underpins the principles for generating reactive power in single-phase transformerless photovoltaic (PV) inverters. Two mainstream and widely adopted PV inverters are explored, i.e., H5 and HERIC. With conventional modulation techniques, reactive power cannot be realized in H5 and HERIC due to the absence of freewheeling path in negative power region. Based on the study, modulation techniques are proposed to provide bidirectional current path during freewheeling period. With proposed modulation technique, reactive power control is achieved in H5 and HERIC inverters, without any modification on the converter structures. The performances of the proposed modulation techniques are studied via MATLAB simulation and further validated with experimental results.
23 September 2022 in IEEE Transactions on Power Electronics
In high power motor drive systems, synchronized space vector pulsewidth modulation (synchronized SVPWM) is widely used to guarantee stable control performance. Synchronized SVPWM has a characteristic that the switching frequency varies abruptly when the pulse number transitions. This article proposes a pulse number transition point at which the phase difference is minimized to remove the phase difference of the sampling point that appears during synchronized SVPWM control. In addition, for a smooth pulse number transition of synchronized SVPWM, a compensation method for the magnitude and phase error of the inverter output voltage due to the time delay and a method of removing the existing phase difference without using a phase-locked loop are proposed in consideration of the characteristic of changing switching frequency. The validity and the implementation of the proposed method are verified by experimental results using a high-power inverter driving 332 kW interior permanent magnet synchronous motor (IPMSM).
Most railroad cars employ a natural ventilation cooling method. For this reason, severe problems occur in the control devices for the railroad cars due to the heat generated by the high-power switching loss. Therefore, the traction inverter for the railroad car requires a control method that can reduce the switching loss. In this paper, we propose a control method for an interior permanent magnet synchronous motor in consideration of the driving conditions of the railroad cars. The proposed method combines a variable switching frequency-based synchronous pulse width modulation control method, a flux-weakening control method that considers the maximum voltage modulation index, and an optimized over-modulation method. Through the proposed method, the utilization rate of the DC-link voltage can be maximized while lowering the switching frequency of the traction inverter as much as possible, and the high-performance current control can be performed in the entire speed region of the railroad car. The validity and effectiveness of the proposed method are verified by the simulation results and the experimental results.
This paper proposes a rotation carrier-based discontinuous pulse width modulation (CB-DPWM) method for the five-leg inverter (FLI). The FLI based on two-level topology consists of 10 switching devices for driving dual motors. Therefore, two switching devices can be reduced to compare the configuration using two three-leg inverters for driving dual motors. The proposed pulse width modulation (PWM) method is based on the reference signals which are used in existing carrier-based continuous pulse width modulation (CB-CPWM) method for FLI. In the proposed rotation CB-DPWM method, one of five-leg is periodically clamped to Vdc/2 or -Vdc/2 by adding the offset voltage to the reference voltages of the existing CB-CPWM method. The five reference voltages for all legs are considered to calculate the offset voltage of the proposed rotation CB-DPWM method. Consequently, since the proposed rotation CB-DPWM method has the fewer number of switching than that of the existing CB-CPWM, the switching loss can be reduced and it results in the efficiency improvement. Simulation and experimental results confirm the effectiveness and feasibility of the proposed method.