Salah Abouzaid

Salah Abouzaid

Auto-generated profile, based on publicly available information

Salah Abouzaid

Ruhr University Bochum

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2020 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
WAWael Abdullah Ahmad
Wael Abdullah Ahmad
MKMaciej Kucharski
Maciej Kucharski
AEArzu Ergintav
Arzu Ergintav
SASalah Abouzaid
Salah Abouzaid
JWJan Wessel
Jan Wessel
DKDietmar Kissinger
Dietmar Kissinger
This article demonstrates the implementation of 80- and 160-GHz four-channel radar sensors employing the modular scalable platform based on a single relaxed 40-GHz local oscillator and cascadable transceiver chips. The first two channels synthesize 2 x 2 multiple-input-multiple-output (MIMO) radar at 80 GHz with onboard 8 x 1 patch arrays for enhanced angular resolution, whereas the other two channels employ 160-GHz system-on-chip transceivers with integrated wideband 6-dBi micromachined on-chip antennas for enhanced range resolution. Configurable modulators in each transceiver offer ranging, direction-of-arrival (DoA) estimation, velocity/vibrations measurement, and data communication applications. Frequency-modulated continuous wave (FMCW) is demonstrated with 4-/8-GHz sweep bandwidth at 80/160 GHz corresponding to 3.75-/1.875-cm range resolution. Chirp-sequence FMCW is employed to measure the heartbeat rate of a human, and 78 bpm is measured with 0.06-Hz Doppler resolution. Mechanical vibration rate from a loudspeaker is measured using the CW radar technique, whereas phase-modulated continuous wave is employed for distant selective vibrations measurement. Time-division multiplexing MIMO radar is configured at 80 GHz in a multitarget scenario for DoA estimation, and the targets are distinguished with 25° effective angular resolution. Frequency-division multiplexing MIMO radar technique is demonstrated based on Δ Σ-modulation and binary phase shift keying (BPSK) modulators. Furthermore, the 10-Mb/s BPSK data communication link is evaluated at 80 GHz with a 20-dB signal-to-noise ratio at 1 m. The 160-GHz vector modulators offer additional modulations.

23 May 2023 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Open access
SASalah Abouzaid
Salah Abouzaid
TJTimo Jaeschke
Timo Jaeschke
SKSimon Kueppers
Simon Kueppers
JBJan Barowski
Jan Barowski
NPNils Pohl
Nils Pohl
This article proposes a low-cost and practical alternative to vector network analyzers (VNAs) for characterizing dielectric materials using a calibrated frequency-modulated continuous wave (FMCW) radar measurement setup and a machine learning (ML) model. The calibrated FMCW radar measurement setup has the ability to accurately measure the $S$ -parameters of dielectric materials. In addition, an ML model is developed to extract material parameters such as thickness, dielectric constant, and loss tangent with high accuracy. $K$ -means clustering was additionally applied to significantly reduce the complexity of the neural network (NN). Additionally, a state-of-the-art open-set recognition (OSR) technique was adopted to simultaneously classify known classes and reject unknown classes. The developed model uses a modified version of the class anchor clustering (CAC) distance-based loss, which outperforms the conventional cross-entropy loss. The proposed model was evaluated on several dielectric materials and compared to reference measurements using a VNA and curve fitting. The results indicate that the proposed model is accurate and robust, and that the calibrated radar sensor provides a practical and cost-effective alternative to VNAs in characterizing dielectric materials, as long as the material parameters are within the defined limits.

24 September 2020 in IET Radar, Sonar & Navigation
Verified
Journal Article
Open access
PDF file
SASalah H. Abouzaid
Salah H. Abouzaid
WAWael Abdullah Ahmad
Wael Abdullah Ahmad
TEThomas F. Eibert
Thomas F. Eibert
HNHerman Jalli Ng
Herman Jalli Ng
A distance selective pseudo‐random noise (PRN)‐coded Doppler radar is proposed. The radar is capable of measuring the vital signs of a human in a noisy environment with high precision. The distance selectivity feature is achieved by the use of PRN modulation to focus on the desired target at a certain distance and suppress the Doppler frequencies of other targets at different distances. In addition, an offset signal using Delta–Sigma modulation is generated to cope with the suppression of low‐Doppler frequencies, very close to DC, in AC‐coupled systems. The authors compare the performance of the proposed radar system to a frequency modulated continuous wave radar in measuring the Doppler frequencies of two loudspeakers located at different ranges. In addition, they experimentally evaluated the proposed radar in measuring the vital signs of a human in a noisy environment. The radar is capable of isolating the Doppler frequencies of the vital signs from the surrounding noise. In addition, vital signs information is preserved at higher frequencies away from the high‐pass filter in AC‐coupled systems.

1 January 2026 in IEEE Transactions on Radar Systems
Verified
Journal Article
Open access
SASalah Abouzaid
Salah Abouzaid
LNLeander Nothelle
Leander Nothelle
NPNils Pohl
Nils Pohl