Time-dependent energy spectra of galactic cosmic rays (GCRs) carry fundamental information regarding their origin and propagation. When observed at the Earth, these spectra are significantly affected by the solar wind and the embedded solar magnetic field that permeates the heliosphere, changing significantly over an 11 yr solar cycle. Energy spectra of GCRs measured during different epochs of solar activity provide crucial information for a thorough understanding of solar and heliospheric phenomena. The PAMELA experiment collected data for almost 10 years (2006 June 15–2016 January 23), including the minimum phase of solar cycle 23 and the maximum phase of solar cycle 24. In this paper, we present new spectra for helium nuclei measured by the PAMELA instrument from 2010 January to 2014 September over a three-Carrington-rotation time basis. These data are compared to the PAMELA spectra measured during the previous solar minimum, providing a picture of the time dependence of the helium-nuclei fluxes over a nearly full solar cycle. Time and rigidity dependencies are observed in the proton-to-helium flux ratios. The force-field approximation of the solar modulation was used to relate these dependencies to the shapes of the local interstellar proton and helium-nuclei spectra.
23 November 2021 in IEEE Transactions on Nuclear Science
The ORION chipset, a full-custom multichip readout and processing electronics for the X- $\gamma $ -ray imaging spectrometer (XGIS) on-board the transient high-energy sky and early universe surveyor (THESEUS) space mission, is presented. The XGIS detection plane is arranged in a matrix of 10 $\times $ 10 detection modules, each one composed of 64 CsI(Tl) scintillation bars (4.5 mm $\times $ 4.5 mm $\times $ 30 mm) optically coupled at the top and bottom ends to two 8 $\times $ 8 monolithic silicon drift detector (SDD) matrices. The top SDD, exposed to the X-ray entrance window, performs the double function of low-energy X-ray detection as well as scintillator’s readout, together with the bottom SDD, providing detection and spectroscopic energy range from 2 keV up to 20 MeV. The need to achieve a high-energy resolution, as well as a high sensitive area on the detection plane, led to the development of a chipset organized to have a minimum-area analog readout chip placed in close proximity of the SDD (ORION-FE) and a mixed-signal back-end (ORION-BE) placed a few centimeters further on the back-end board for the additional signal processing and digitization. The multichip readout electronics integrates two dedicated analog processors for low-energy photons up to 30 keV (X-processor) and high-energy photons up to 5 MeV ( $\gamma $ -processor), allowing a spectroscopy-grade resolution in the 4 decades energy band (2 keV–20 MeV) of the XGIS, with a simulated power consumption of 1.55 mW/pixel. The ORION prototype was bonded to two ~25 mm 2 SDDs, and extensively characterized in terms of pulse shaping, pulse discrimination, and stretching functionality, as well as linearity, dynamic range, and spectroscopic resolution. An optimum equivalent noise charge (ENC) at −20 °C of 24.3 el. r.m.s. on the X-channel [212 eV full-width at half-maximum (FWHM) on Si], and 39.6 el. r.m.s. on the $\gamma $ -channel [3.7 keV FWHM on CsI(Tl)] has been recorded.
HERD is a future experiment for the direct detection of high energy cosmic rays. The instrument is based on a calorimeter optimized not only for a good energy resolution but also for a large acceptance. Each crystal composing the calorimeter is equipped with two read-out systems: one based on wavelength-shifting fibers and the other based on two photodiodes with different active areas assembled in a monolithic package. In this paper, we describe the photodiode read-out system, focusing on experimental requirements, design and estimated performances. Finally, we show how these features lead to the flight model project of the photodiode read-out system.
18 October 2021 in Journal of Synchrotron Radiation
X-ray absorption fine-structure (XAFS) spectroscopy can assess the chemical speciation of the elements providing their coordination and oxidation state, information generally hidden to other techniques. In the case of trace elements, achieving a good quality XAFS signal poses several challenges, as it requires high photon flux, counting statistics and detector linearity. Here, a new multi-element X-ray fluorescence detector is presented, specifically designed to probe the chemical speciation of trace 3d elements down to the p.p.m. range. The potentialities of the detector are presented through a case study: the speciation of ultra-diluted elements (Fe, Mn and Cr) in geological rocks from a calcareous formation related to the dispersal processes from Ontong (Java) volcanism (mid-Cretaceous). Trace-elements speciation is crucial in evaluating the impact of geogenic and anthropogenic harmful metals on the environment, and to evaluate the risks to human health and ecosystems. These results show that the new detector is suitable for collecting spectra of 3d elements in trace amounts in a calcareous matrix. The data quality is high enough that quantitative data analysis could be performed to determine their chemical speciation.
7 February 2023 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment