Nabil Zemiti

Nabil Zemiti

Auto-generated profile, based on publicly available information

Nabil Zemiti

University of Montpellier

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2019
Verified
Conference Paper
Open access
Yuhang YeYuhang Ye
Yuhang Ye
Chao LiuChao Liu
Chao Liu
NZNabil Zemiti
Nabil Zemiti
Chenguang YangChenguang Yang
Chenguang Yang
Electromyogram (EMG) signal has been long used in human-robot interface in literature, especially in the area of rehabilitation. Recent rapid development in artificial intelligence (AI) has provided powerful machine learning tools to better explore the rich information embedded in EMG signals. For our specific application task in this work, i.e. estimate human finger force based on EMG signal, a LightGBM (Gradient Boosting Machine) model has been used. The main contribution of this study is the development of an objective and automatic optimal feature selection algorithm that can minimize the number of features used in the LightGBM model in order to simplify implementation complexity, reduce computation burden and maintain comparable estimation performance to the one with full features. The performance of the LightGBM model with selected optimal features is compared with 4 other popular machine learning models based on a dataset including 45 subjects in order to show the effectiveness of the developed feature selection method.

19 August 2023 in International Journal of Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
MBMarie De Boutray
Marie De Boutray
LCL. Cuau
L. Cuau
MOM. Ohayon
M. Ohayon
RGR. Garrel
R. Garrel
PPP. Poignet
P. Poignet
NZN. Zemiti
N. Zemiti

17 February 2023 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
JSJoão Cavalcanti Santos
João Cavalcanti Santos
LCLenaïc Cuau
Lenaïc Cuau
PPPhilippe Poignet
Philippe Poignet
NZNabil Zemiti
Nabil Zemiti
The present letter proposes a predictive path following control (PPFC) that controls 5 degrees of freedom (DoFs) of the end-effector while the remaining (decoupled) translational DoF should be controlled by an external controller. This PPFC is particularly useful for the path following on surfaces with geometric uncertainties such that the external controller can be independently designed to manage the interaction between the tool and the surface. Therefore, the proposed strategy turns out to be a versatile control scheme that can be integrated with external controllers designed for applications such as robotic surface finishing, welding and 3D printing on complex surfaces. The corresponding optimal control problem (OCP) considers mainly the positioning and orientation errors, tangential velocity and control input amplitudes. The proposed PPFC is validated experimentally in the context of robotic 3D bio-printing. A 7-DoF redundant manipulator equipped with a distance sensor is used to handle a print head through the desired print path. The distance measurements are used by an external controller to correct the printed layer height. The obtained accuracy is consistent with the repeatability of the used manipulator and computation time is compatible with high frequency controllers.

16 November 2020 in Advanced Intelligent Systems
Verified
Journal Article
Open access
PDF file
LCLingbo Cheng
Lingbo Cheng
JCJay Carriere
Jay Carriere
JPJakub Piwowarczyk
Jakub Piwowarczyk
DADaniel Aalto
Daniel Aalto
NZNabil Zemiti
Nabil Zemiti
Mahdi TavakoliMahdi Tavakoli
Mahdi Tavakoli
Herein, a semiautonomous robot control system for mandible reconstruction surgery is proposed. To reconstruct a segmental defect of the mandible caused by cancerous tissue, a piece of matched fibula bone is often segmented and used to replace the removed mandible section. Herein, to provide guidance to the surgeon during fibula segmentation according to the reconstruction surgical plan and improve the fibula bone cutting accuracy, an admittance‐controlled robotic assistant incorporating 3D augmented reality (AR) visualization and haptic virtual fixtures (VFs) is proposed. The admittance controller is used to reduce the surgeon's hand tremor. VF and AR are used to provide haptic and visual guidance to the surgeon, respectively. A feasibility study is conducted through a comparison of fibula osteotomies when performed with image‐guided surgery, AR‐guided surgery, VF‐guided robot‐assisted surgery, and AR‐ and VF‐guided robot‐assisted surgery. Experimental results show the effectiveness of the proposed admittance‐controlled robotic assistant with AR and VF compared with the other three methods. The proposed method is found to be able to increase precision of the osteotomized segments with a lower average linear variation of 1.04 ± 0.79 mm and a lower average angular variation of 1.83 ± 1.85° compared with the virtual preoperative plan.

22 March 2023 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
LLLucas Lavenir
Lucas Lavenir
JSJoão C. Santos
João C. Santos
NZNabil Zemiti
Nabil Zemiti
AKAkil Kaderbay
Akil Kaderbay
FVFrédéric Venail
Frédéric Venail
PPPhilippe Poignet
Philippe Poignet
Objective: In this paper, we focus on the carrying out and validation of minimally invasive three-dimensional (3D) ultrasound (US) imaging of the auditory system, which is based on a new miniaturized endoscopic 2D US transducer. Methods: This unique probe consists of a 18 MHz 24 elements curved array transducer with a distal diameter of 4 mm so it can be inserted into the external auditory canal. Typical acquisition is achieved by rotating such a transducer around its own axis using a robotic platform. Reconstruction of a US volume from the set of acquired B-scans during the rotation is then performed using scan-conversion. The accuracy of the reconstruction procedure is evaluated using a dedicated phantom that includes a set of wires as reference geometry. Results: Twelve acquisitions obtained from different probe poses are compared to a micro-computed tomographic model of the phantom, leading to a maximum error of 0.20 mm. Additionally, acquisitions with a cadaveric head highlight the clinical applicability of this set up. Structures of the auditory system such as the ossicles and the round window can be identified from the obtained 3D volumes. Conclusion: These results confirm that our technique enables the accurate imaging of the middle and inner ears without having to deteriorate the surrounding bone. Significance: Since US is a real-time, wide available and non-ionizing imaging modality, our acquisition setup could facilitate the minimally invasive diagnosis and surgical navigation for otology in a fast, cost-effective and safe way.

30 October 2020 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
LLLucas Lavenir
Lucas Lavenir
NZNabil Zemiti
Nabil Zemiti
MAMohamed Akkari
Mohamed Akkari
GSGérard Subsol
Gérard Subsol
FVFrédéric Venail
Frédéric Venail
PPPhilippe Poignet
Philippe Poignet