Reza Lotfi

Reza Lotfi

Auto-generated profile, based on publicly available information

Reza Lotfi

Department of Electrical Engineering, Ferdowsi University of Mashhad, Mashhad, Iran

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2018 in IEEE Solid-State Circuits Letters
Verified
Journal Article
Closed access
RLReza Lotfi
Reza Lotfi
MSMehdi Saberi
Mehdi Saberi
SHS. Rasool Hosseini
S. Rasool Hosseini
AAAmir Reza Ahmadi-Mehr
Amir Reza Ahmadi-Mehr
RSRobert Staszewski
Robert Staszewski
This letter proposes a new level-shifting structure that can convert extremely low levels of input voltages to high output voltages while maintaining excellent delay and power dissipation. In order to reduce contention and voltage swing in the internal nodes, the proposed circuit uses a diode-connected level shifter between gate terminals of the output inverter. Using a control circuit, only during the high-to-low transitions of the output, a current is forced into the diode-connected device. Measurement results demonstrate that the proposed circuit can consume as small energy as 4.2 fJ/transition with VDDL and VDDH of 0.35 V and 1.1 V, respectively, when implemented in a 40-nm CMOS technology. Furthermore, when fabricated in a 180-nm technology, the level-shifting circuit can convert VDDL as small as 80 mV to 1.8 V without using low-threshold devices.

25 July 2012 in Analog Integrated Circuits and Signal Processing
Verified
Journal Article
Closed access
PDF file
SBSamaneh Babayan-Mashhadi
Samaneh Babayan-Mashhadi
RLReza Lotfi
Reza Lotfi

26 October 2016 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
EREhsan Rahiminejad
Ehsan Rahiminejad
MSMehdi Saberi
Mehdi Saberi
RLReza Lotfi
Reza Lotfi
A novel signal-specific power-efficient analog-to-digital converter (ADC) is proposed for sensor-interface applications. Instead of digitizing each analog sample independently, the proposed ADC determines the digital code corresponding to each new input sample by digitizing the difference of two consecutive samples. Therefore, for the applications with low-varying input signals, such as image sensors and ECG readouts, the difference of two consecutive samples is much smaller than the ADC full-scale range for the majority of the input samples, the power consumption of the capacitive digital-to-analog converter, the comparator, and the digital circuits of the proposed ADC is saved due to reducing the ADC activity. The prototype was fabricated using a 0.18-μm CMOS technology. Measurement results of 1 V, 8 bit, 20 kS/s ADC confirm that for a 10-kHz input sine wave, the effective number of bits is 7 while the power consumption of the entire ADC is 1.12 μW. However, for the same sampling rate, the power consumption is only 106 nW for a low-varying 100-Hz input sine wave.

19 November 2008 in Analog Integrated Circuits and Signal Processing
Verified
Journal Article
Closed access
PDF file
HAHamed Aminzadeh
Hamed Aminzadeh
RLReza Lotfi
Reza Lotfi
KMKhalil Mafinezhad
Khalil Mafinezhad

8 June 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SGSara Ghamsari
Sara Ghamsari
MQMohammad Tavakkoli Qouchani
Mohammad Tavakkoli Qouchani
SRSadjad Rahmanpour
Sadjad Rahmanpour
PZPayman Amel Zendedel
Payman Amel Zendedel
RLReza Lotfi
Reza Lotfi
Large-array resistive sensors have nowadays found various applications in a variety of medical and industrial systems. In this paper, a two-step readout procedure is proposed, which increases the average speed of the readout for the input patterns, located in an area much smaller than the entire array. In the proposed method, during the first step, only a spatially coarse scan is performed where the location of the input is roughly estimated. Then, during the second step, the values of the resistors are accurately measured, just within the allocated area. Measurement results of a 52×44 resistive array used in a plantar pressure scanner show that the average readout time for a gait pattern is reduced from 23 ms for the conventional circuit to 5.7 ms using the proposed technique.

1 May 2011
Verified
Conference Paper
Closed access
HSHassan Sepehrian
Hassan Sepehrian
MSMehdi Saberi
Mehdi Saberi
RLReza Lotfi
Reza Lotfi
This paper presents a modified structure and a new switching algorithm in successive-approximation analog-to-digital converters to reduce the power consumption. This technique is more efficient in applications where the input signal activity is low most of the time such as biomedical signals. For slow-varying samples, only the least significant bits of the new analog sample are extracted leading to power saving in both the capacitor-based DAC and the comparator. For an Electrocardiogram signal and with the proposed structure, the simulated power consumption of the DAC, the comparator and the entire ADC for an 8-bit 1-kS/s converter are 75%, 43% and 50% smaller than those of a conventional architecture, respectively.