Moqiu Zhang

Moqiu Zhang

Auto-generated profile, based on publicly available information

Moqiu Zhang

Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Hong Kong, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MZMoqiu Zhang
Moqiu Zhang
Lidong YangLidong Yang
Lidong Yang
CZChong Zhang
Chong Zhang
ZYZhengxin Yang
Zhengxin Yang
Li ZhangLi Zhang
Li Zhang
Simultaneous magnetic localization and actuation in a human-scale workspace are challenging but essential for medical applications such as whole gastrointestinal (GI) tract monitoring and blood clot clearance in the leg. In this paper, we propose a five-dimensional (5-D) magnetic localization and actuation system that can track and actuate magnetic robots in a cylindrical workspace with a diameter of 500 mm. Based on the eye-in-hand configuration of the sensor array and the flexibility of the mobile electromagnetic manipulation system (mEMS), we realize a high localization accuracy in a large workspace with only twenty-five sensors. Moreover, we design an accurate magnetic field modeling method that can attenuate the electromagnets’ hysteresis and provide a precise actuation field estimation. Taking advantage of the mobile sensor array, we developed a signal-quality-based tracking strategy (STS) that could improve the localization performance by adjusting the movement of the sensor array. The effectiveness and advantages of the proposed methods are verified by simulations and experiments. Results show that the signal-quality-based tracking strategy could decrease 25% position root-mean-square error (RMSE). The resulting position RMSE and orientation RMSE are 2.02 mm and 8.24° respectively. We experimentally prove the viability of the proposed strategy by propelling a magnetic helical robot through a 400 mm long three-dimensional (3-D) twisted silicone phantom.

24 March 2023 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
Lidong YangLidong Yang
Lidong Yang
MSMengmeng Sun
Mengmeng Sun
MZMoqiu Zhang
Moqiu Zhang
Li ZhangLi Zhang
Li Zhang
Soft microrobotics has recently been an active field that advances new microrobot design, adaptive motion, and biomedical applications. In this work, we study the ferrofluid robot (FR), which has soft nature and exhibits paramagnetism. Currently, motion of the FR is usually realized by magnetic force, and the task execution requires relatively complex systems for simultaneous field and gradient control. To enable the FR with more motion modes for environment and task adaptability, we program three dynamic field forms and realize three corresponding torque-actuated motion modes: Rolling , Wobbling , and Oscillating . Together with the force-based Dragging mode, we provide a complete motion control scheme for the FR. As this scheme only requires 3-D dynamic fields or gradients for actuation, the complexity of the magnetic actuation system is reduced. We formulate the motion and deformation actuation principles of the FR, and the four motion modes are demonstrated and characterized. With the implementation of automated tracking and control algorithms, controllability of the new torque-based modes is testified. We then fabricate different kinds of environments and cargoes to validate the environment and task adaptability of the FR by using the proposed scheme. Especially, we implement the scheme on a self-constructed system consisting of three mobile coils, and experiments realize the long-distance navigation of the FR via Rolling or Dragging modes. The ultrasound-guided navigation in a 3-D tissue-mimicking endovascular environment shows the potential for delivery applications.

20 February 2025 in Nature Synthesis
Verified
Journal Article
Closed access
PDF file
NXNeng Xia
Neng Xia
DJDongdong Jin
Dongdong Jin
ZYZhengxin Yang
Zhengxin Yang
CPChengfeng Pan
Chengfeng Pan
LSLin Su
Lin Su
Li ZhangLi Zhang
Li Zhang

30 November 2022 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
Lidong YangLidong Yang
Lidong Yang
MZMoqiu Zhang
Moqiu Zhang
ZYZhengxin Yang
Zhengxin Yang
Li ZhangLi Zhang
Li Zhang
Recent studies on magnetic microrobotics for biomedical applications have resulted in varieties of magnetic actuation systems. However, the simultaneous actuation and tracking of magnetic microrobots in large workspace (e.g., the human-body size) remains challenging due to the fast decay of magnetic fields and the contradiction between resolution and field of view of a feedback instrument. Our previous work reported the concept of the parallel-mobile-coil system (PMCS), which comprises three electromagnetic coils that can move in large 3-D space for microrobotic actuation. Here, to make the PMCS have adaptability to different actuation scenarios or microrobot types, we propose three different control modes by utilizing the mobility of the coils. The torque control, force-assisted torque control, and force control modes are designed for pure torque actuation with energy conservation, torque actuation with force assistance, and pure force actuation, respectively. Comparative simulations and experiments validate the effectiveness of the three control modes. Moreover, to endow the system with in-vivo feedback capability, we implement Hall-effect sensors and demonstrate the 3-D large-workspace actuation based on magnetic localization.

19 December 2022 in IEEE Transactions on Automation Science and Engineering
Verified
Journal Article
Closed access
Lidong YangLidong Yang
Lidong Yang
ZYZhengxin Yang
Zhengxin Yang
MZMoqiu Zhang
Moqiu Zhang
JJJialin Jiang
Jialin Jiang
HYHaojin Yang
Haojin Yang
Li ZhangLi Zhang
Li Zhang
In this work, we study the optimal parameter design and microrobotic navigation control of the parallel-mobile-coil system (PMCS) that consists of three mobile electromagnetic coils. With motion driven by a parallel mechanism, the three coils can move in 3D large space and keep as close as possible to the controlled microrobot for magnetic actuation. Although promising for microrobotic applications, how to design such a type of system for a specific workspace requirement is untackled. Regarding this issue, we propose a computational design method, by which one can calculate the structural parameters of a PMCS starting from a required cylindrical workspace. With the derived performance metrics for motion actuation and magnetic actuation of the PMCS, the system actuation performance (composed of motion and magnetic actuation) is optimized. Utilizing the design method, we optimally construct a prototype PMCS for microrobotic navigation. We then conduct experiments to validate the demanding field/force generation capability of the PMCS and demonstrate the navigation control of different types of magnetic microrobots. In particular, we design closed-loop motion controllers for both torque and force-driven microrobots, using which automated large-workspace and high-accuracy trajectory tracking is realized. Note to Practitioners —This work is motivated by the recent wide interest in magnetic microrobots. Driven by external magnetic fields, magnetic microrobots can navigate in a wireless manner for targeted delivery/therapy. To promote microrobot applications to the human body, a magnetic actuation system with large workspace is desirable. However, due to the fast decay of magnetic field, the commonly used stationary coil-based magnetic actuation systems have the workspace scalability problem. Thus, several mobile-coil-based systems have been designed. In this work, we propose an optimal design method for the PMCS, using which one can design a PMCS starting from a cylindrical workspace with performance being optimized. We construct a PMCS prototype with a workspace of $\Phi 230 \times 100$ mm $^3$ , and we then study the automated microrobotic navigation control methods for the PMCS. Controllers are designed for different types of magnetic microrobots, and experiments show that, using the controllers, the PMCS can perform automated large-workspace microrobotic navigation control with high accuracy.

27 September 2021
Verified
Conference Paper
Closed access
MZMoqiu Zhang
Moqiu Zhang
Lidong YangLidong Yang
Lidong Yang
CZChong Zhang
Chong Zhang
ZYZhengxin Yang
Zhengxin Yang
Li ZhangLi Zhang
Li Zhang
Large workspace localization of magnetic robots is important for medical applications. This paper presents a novel localization strategy to achieve simultaneous localization and actuation of magnetic robots using hall-effect sensors. We integrate 25 sensors into a sensing probe and mount it on to the mobile-coil system, which realizes accurate sensing and actuation of magnetic devices within a cylindrical workspace of ϕ500 mm×150 mm. Simulation results show the average localization error using the proposed method is 1.7 mm. A verification experiment is conducted to prove the design advantages; Another two experiments are conducted to demonstrate the simultaneous actuation and localization of a torque-driven robot and a force-driven floating robot respectively. For the force-driven floating robot, the average variation between the localization results and the desired trajectory is less than 2 mm.