Haojin Yang

Haojin Yang

Auto-generated profile, based on publicly available information

Haojin Yang

Department of Mechanical and Automation Engineering, The Chinese University of Hong Kong, Hong Kong SAR, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2022 in Science Advances
Verified
Journal Article
Open access
Yue DongYue Dong
Yue Dong
LWLu Wang
Lu Wang
ZZZifeng Zhang
Zifeng Zhang
FJFengtong Ji
Fengtong Ji
KCKai Fung Chan
Kai Fung Chan
Li ZhangLi Zhang
Li Zhang
Occlusion of the T-tube (tympanostomy tube) is a common postoperative sequela related to bacterial biofilms. Confronting biofilm-related infections of T-tubes, maneuverable and effective treatments are still challenging presently. Here, we propose an endoscopy-assisted treatment procedure based on the wobbling Fe 2 O 3 helical micromachine (HMM) with peroxidase-mimicking activity. Different from the ideal corkscrew motion, the Fe 2 O 3 HMM applies a wobbling motion in the tube, inducing stronger mechanical force and fluid convections, which not only damages the biofilm occlusion into debris quickly but also enhances the catalytic generation and diffusion of reactive oxygen species (ROS) for killing bacteria cells. Moreover, the treatment procedure, which integrated the delivery, actuation, and retrieval of Fe 2 O 3 HMM, was validated in the T-tube implanted in a human cadaver ex vivo. It enables the visual operation with ease and is gentle to the tympanic membrane and ossicles, which is promising in the clinical application.

20 June 2025 in Science Advances
Verified
Journal Article
Open access
MZMoqiu Zhang
Moqiu Zhang
Lidong YangLidong Yang
Lidong Yang
HYHaojin Yang
Haojin Yang
LSLin Su
Lin Su
JXJunnan Xue
Junnan Xue
Li ZhangLi Zhang
Li Zhang
Endovascular interventions require fast access to affected regions, followed by effective treatment. Catheterizations are effective approaches for treating vascular diseases; however, they face challenges in accessibility, efficiency, and invasiveness in narrow, tortuous vascular systems. This study presents a submillimeter magnetically actuated soft rotatable-tipped microcatheter (MSRM) designed to access small blood vessels and provide efficient, minimally invasive therapeutic interventions for blood clot treatment. The MSRM’s rotatable tip design enhances accessibility and navigation speed through a rotation-assisted active steering strategy. Improved blood clot treatment efficiency is achieved through the MSRM’s multifunctionality: It can accelerate drug-blood clot interactions, mechanically break down blood clots, and retrieve clot debris. The low invasiveness is attributed to the soft material design and conservative actuation strategy. The performance of the MSRM is validated in both in vitro phantom studies and in vivo rabbit models, and the invasiveness is evaluated using a human placenta model.

24 October 2025 in Science Advances
Verified
Journal Article
Open access
LSLin Su
Lin Su
DJDongdong Jin
Dongdong Jin
NXNeng Xia
Neng Xia
BHBo Hao
Bo Hao
YJYihang Jiang
Yihang Jiang
Li ZhangLi Zhang
Li Zhang
Endoluminal stent implantation is a common intervention strategy for treating obstructive lesions, but conventional delivery systems struggle to reach deep, tortuous ducts. To overcome this limitation, we present a magnetically controlled microrobot that integrates two functional modules: a magnetic actuation (MA) module for agile navigation and an ultrasound-responsive self-expanding stent module (ST module) for lesion-specific dilation. The system uses a dynamically tunable assembly mechanism governed by rotational direction enabling integrated locomotion (clockwise) and on-demand module separation (counterclockwise) at stenotic sites. The platform is compatible with intraoperative ultrasound, allowing real-time navigation and thermally triggered expansion in physiological environments. By synergizing programmable magnetic actuation, ultrasound-mediated expansion, and clinical workflow compatibility, the robot can navigate tortuous phantom ducts, achieving controlled stent deployment within 3 seconds and complete expansion within 30 seconds, permitting minimally invasive treatment of biliary strictures. This work advances microrobotic stent delivery by overcoming key barriers to clinical translation in endoluminal interventions.

13 June 2022 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
HYHaojin Yang
Haojin Yang
ZYZhengxin Yang
Zhengxin Yang
DJDongdong Jin
Dongdong Jin
LSLin Su
Lin Su
KCKai Fung Chan
Kai Fung Chan
Li ZhangLi Zhang
Li Zhang
Primary acquired nasolacrimal duct obstruction (PANDO) is the commonest cause of obstructive tearing and can lead to infections including dacryocystitis, cellulitis and postoperative endophthalmitis. External or endoscopic dacryocystorhinostomy (DCR) is the current standard treatment of PANDO. However, DCR is technically challenging, invasive, and not without risks, especially epistaxis and recurrent obstruction. We designed and constructed a magnetic micro-driller system for nasolacrimal duct (NLD) recanalization as a minimally invasive alternative to conventional treatment. The drilling microrobot consists of a 3D printed helical tip and a permanent magnet. A magnetic actuation system with three electromagnets is developed to well accommodate the human anatomy and generate three-dimensional dynamic magnetic fields along the NLD. To navigate the microrobot safely inside the NLD, the micro-driller is integrated with a guidewire and a feed drive system to control its motion. Furthermore, a force sensor is installed on the proximal end of the guidewire to report the force signal, through which the state of the micro-driller can be detected and the control input can be decided. Our results show that the guide-wired microrobot can navigate through the NLD phantom and remove the blockage automatically. The proposed strategy provides a microrobot-assisted endoluminal solution for NLD recanalization with improved safety by introducing the magnetic manipulation and force control method.

19 December 2022 in IEEE Transactions on Automation Science and Engineering
Verified
Journal Article
Closed access
Lidong YangLidong Yang
Lidong Yang
ZYZhengxin Yang
Zhengxin Yang
MZMoqiu Zhang
Moqiu Zhang
JJJialin Jiang
Jialin Jiang
HYHaojin Yang
Haojin Yang
Li ZhangLi Zhang
Li Zhang
In this work, we study the optimal parameter design and microrobotic navigation control of the parallel-mobile-coil system (PMCS) that consists of three mobile electromagnetic coils. With motion driven by a parallel mechanism, the three coils can move in 3D large space and keep as close as possible to the controlled microrobot for magnetic actuation. Although promising for microrobotic applications, how to design such a type of system for a specific workspace requirement is untackled. Regarding this issue, we propose a computational design method, by which one can calculate the structural parameters of a PMCS starting from a required cylindrical workspace. With the derived performance metrics for motion actuation and magnetic actuation of the PMCS, the system actuation performance (composed of motion and magnetic actuation) is optimized. Utilizing the design method, we optimally construct a prototype PMCS for microrobotic navigation. We then conduct experiments to validate the demanding field/force generation capability of the PMCS and demonstrate the navigation control of different types of magnetic microrobots. In particular, we design closed-loop motion controllers for both torque and force-driven microrobots, using which automated large-workspace and high-accuracy trajectory tracking is realized. Note to Practitioners —This work is motivated by the recent wide interest in magnetic microrobots. Driven by external magnetic fields, magnetic microrobots can navigate in a wireless manner for targeted delivery/therapy. To promote microrobot applications to the human body, a magnetic actuation system with large workspace is desirable. However, due to the fast decay of magnetic field, the commonly used stationary coil-based magnetic actuation systems have the workspace scalability problem. Thus, several mobile-coil-based systems have been designed. In this work, we propose an optimal design method for the PMCS, using which one can design a PMCS starting from a cylindrical workspace with performance being optimized. We construct a PMCS prototype with a workspace of $\Phi 230 \times 100$ mm $^3$ , and we then study the automated microrobotic navigation control methods for the PMCS. Controllers are designed for different types of magnetic microrobots, and experiments show that, using the controllers, the PMCS can perform automated large-workspace microrobotic navigation control with high accuracy.

15 May 2026 in Science Advances
Verified
Journal Article
Open access
HDHuihui Du
Huihui Du
SYShihao Yang
Shihao Yang
JGJunjia Guo
Junjia Guo
XWXin Wang
Xin Wang
BSBonan Sun
Bonan Sun
Li ZhangLi Zhang
Li Zhang
Biofilm infections in submillimeter interstices at soft tissue-implant/hard tissue interfaces (infection pockets) pose substantial health risks. Traditional surgical and microrobotic strategies struggle to address biofilms in these multicurvature spaces. Here, we report the bridging effect of microswarm self-assembled from magnetic hydrogel particles to eradicate biofilms in infection pockets. The microswarm dynamically bridges dual surfaces within infection pockets, enabling continuous, stable contact and force delivery across concave, plane, and convex surfaces through optimized thickness and shear force. The synergy of enzymatic degradation and mechanical disruption enhances biofilm eradication efficiency by eightfold compared to mechanical disruption alone. A multifunctional hydrogel filler is further used to remove biofilm debris and inhibit microbial recolonization, eventually achieving >99% biofilm elimination in ex vivo and in vivo models. This strategy uses the bridging effect, shape reconfigurability, and enzymatic-mechanical synergy of microswarm, offering a minimally invasive, site-specific solution for deep-tissue infections and persistent biofilms, with reduced reliance on antibiotics.