Martin Donoval

Martin Donoval

Auto-generated profile, based on publicly available information

Martin Donoval

Institute of Electronics and Photonics, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology, Ilkovičova 3, 81219 Bratislava, Slovakia

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
DVDiana Vitazkova
Diana Vitazkova
EFErik Foltán
Erik Foltán
HKHelena Kosnáčová
Helena Kosnáčová
MMMichal Micjan
Michal Micjan
MDMartin Donoval
Martin Donoval
Erik VavrinskyErik Vavrinsky
Erik Vavrinsky
This article explores the importance of wearable and remote technologies in healthcare. The focus highlights its potential in continuous monitoring, examines the specificity of the issue, and offers a view of proactive healthcare. Our research describes a wide range of device types and scientific methodologies, starting from traditional chest belts to their modern alternatives and cutting-edge bioamplifiers that distinguish breathing from chest impedance variations. We also investigated innovative technologies such as the monitoring of thorax micromovements based on the principles of seismocardiography, ballistocardiography, remote camera recordings, deployment of integrated optical fibers, or extraction of respiration from cardiovascular variables. Our review is extended to include acoustic methods and breath and blood gas analysis, providing a comprehensive overview of different approaches to respiratory monitoring. The topic of monitoring respiration with wearable and remote electronics is currently the center of attention of researchers, which is also reflected by the growing number of publications. In our manuscript, we offer an overview of the most interesting ones.

6 April 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
Erik VavrinskyErik Vavrinsky
Erik Vavrinsky
NENiloofar Ebrahimzadeh Esfahani
Niloofar Ebrahimzadeh Esfahani
MHMichal Hausner
Michal Hausner
AKAnton Kuzma
Anton Kuzma
VRVratislav Režo
Vratislav Režo
HKHelena Kosnáčová
Helena Kosnáčová
Optical sensors play an increasingly important role in the development of medical diagnostic devices. They can be very widely used to measure the physiology of the human body. Optical methods include PPG, radiation, biochemical, and optical fiber sensors. Optical sensors offer excellent metrological properties, immunity to electromagnetic interference, electrical safety, simple miniaturization, the ability to capture volumes of nanometers, and non-invasive examination. In addition, they are cheap and resistant to water and corrosion. The use of optical sensors can bring better methods of continuous diagnostics in the comfort of the home and the development of telemedicine in the 21st century. This article offers a large overview of optical wearable methods and their modern use with an insight into the future years of technology in this field.

15 November 2012 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
AKAnton Kuzma
Anton Kuzma
Martin WeisMartin Weis
Martin Weis
SFSona Flickyngerova
Sona Flickyngerova
JJJan Jakabovic
Jan Jakabovic
AŠAlexander Šatka
Alexander Šatka
DDDaniel Donoval
Daniel Donoval
Surface plasmon resonance of gold and silver nanoparticle (NP) layers is investigated by the experiment as well as simulations. Although the good agreement was found for gold NP film, a significant mismatch in the resonance energy for silver NP film was observed. The deviation was assigned to the presence of silver oxide (Ag2O ) in silver NPs. As an alternative to the NP size-dependent Drude model, the analysis based on effective medium approximation for refractive index of Ag-Ag2O material system is carried out and compared with the core-shell model. Both Mie's model and numerical simulation results illustrate shift of the surface plasmon resonance due to silver NP surface oxidation.

1 February 2017 in Applied Surface Science
Verified
Journal Article
Closed access
MDMartin Donoval
Martin Donoval
MMMichal Micjan
Michal Micjan
MNMiroslav Novota
Miroslav Novota
JNJuraj Nevrela
Juraj Nevrela
SKSona Kovacova
Sona Kovacova
Martin WeisMartin Weis
Martin Weis

7 May 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Erik VavrinskyErik Vavrinsky
Erik Vavrinsky
JSJan Subjak
Jan Subjak
MDMartin Donoval
Martin Donoval
AWAlexandra Wagner
Alexandra Wagner
TZTomas Zavodnik
Tomas Zavodnik
HKHelena Kosnáčová
Helena Kosnáčová
Modern Holter devices are very trendy tools used in medicine, research, or sport. They monitor a variety of human physiological or pathophysiological signals. Nowadays, Holter devices have been developing very fast. New innovative products come to the market every day. They have become smaller, smarter, cheaper, have ultra-low power consumption, do not limit everyday life, and allow comfortable measurements of humans to be accomplished in a familiar and natural environment, without extreme fear from doctors. People can be informed about their health and 24/7 monitoring can sometimes easily detect specific diseases, which are normally passed during routine ambulance operation. However, there is a problem with the reliability, quality, and quantity of the collected data. In normal life, there may be a loss of signal recording, abnormal growth of artifacts, etc. At this point, there is a need for multiple sensors capturing single variables in parallel by different sensing methods to complement these methods and diminish the level of artifacts. We can also sense multiple different signals that are complementary and give us a coherent picture. In this article, we describe actual interesting multi-sensor principles on the grounds of our own long-year experiences and many experiments.

1 December 2016 in IEEE Transactions on Electron Devices
Verified
Journal Article
Open access
ACAleš Chvála
Aleš Chvála
JMJuraj Marek
Juraj Marek
PPPatrik Pribytny
Patrik Pribytny
AŠAlexander Šatka
Alexander Šatka
MDMartin Donoval
Martin Donoval
DDDaniel Donoval
Daniel Donoval
In this brief, obtained results of the electrothermal analysis of multifinger power high-electron mobility transistors (HEMTs) are presented. The analysis of thermal and electrical behavior is supported by effective 3-D electrothermal device simulation method developed for Synopsys TCAD Sentaurus environment using mixed-mode setup. The effects of multifinger HEMT structure metallization layout design are described and studied. Simulation results depict the significant effect of metallization geometry on the electrothermal properties and behavior of the power multifinger HEMTs.