Michal Micjan

Dr. Michal Micjan


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2024 in Biosensors
Verified
Journal Article
Open access
PDF file
DVDiana Vitazkova
Diana Vitazkova
EFErik Foltán
Erik Foltán
HKHelena Kosnáčová
Helena Kosnáčová
MMMichal Micjan
Michal Micjan
MDMartin Donoval
Martin Donoval
Erik VavrinskyErik Vavrinsky
Erik Vavrinsky
This article explores the importance of wearable and remote technologies in healthcare. The focus highlights its potential in continuous monitoring, examines the specificity of the issue, and offers a view of proactive healthcare. Our research describes a wide range of device types and scientific methodologies, starting from traditional chest belts to their modern alternatives and cutting-edge bioamplifiers that distinguish breathing from chest impedance variations. We also investigated innovative technologies such as the monitoring of thorax micromovements based on the principles of seismocardiography, ballistocardiography, remote camera recordings, deployment of integrated optical fibers, or extraction of respiration from cardiovascular variables. Our review is extended to include acoustic methods and breath and blood gas analysis, providing a comprehensive overview of different approaches to respiratory monitoring. The topic of monitoring respiration with wearable and remote electronics is currently the center of attention of researchers, which is also reflected by the growing number of publications. In our manuscript, we offer an overview of the most interesting ones.

17 February 2025 in Biosensors
Verified
Journal Article
Open access
PDF file
DVDiana Vitazkova
Diana Vitazkova
HKHelena Kosnáčová
Helena Kosnáčová
DTDaniela Turonova
Daniela Turonova
EFErik Foltán
Erik Foltán
MJMartin Jagelka
Martin Jagelka
Erik VavrinskyErik Vavrinsky
Erik Vavrinsky
This paper explores the progressive era of sleep monitoring, focusing on wearable and remote devices contributing to advances in the concept of home polysomnography. We begin by exploring the basic physiology of sleep, establishing a theoretical basis for understanding sleep stages and associated changes in physiological variables. The review then moves on to an analysis of specific cutting-edge devices and technologies, with an emphasis on their practical applications, user comfort, and accuracy. Attention is also given to the ability of these devices to predict neurological disorders, particularly Alzheimer’s and Parkinson’s disease. The paper highlights the integration of hardware innovations, targeted sleep parameters, and partially advanced algorithms, illustrating how these elements converge to provide reliable sleep health information. By bridging the gap between clinical diagnosis and real-world applicability, this review aims to elucidate the role of modern sleep monitoring tools in improving personalised healthcare and proactive disease management.

11 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Erik VavrinskyErik Vavrinsky
Erik Vavrinsky
TZTomas Zavodnik
Tomas Zavodnik
TDTomas Debnar
Tomas Debnar
LCLubos Cernaj
Lubos Cernaj
JKJozef Kozarik
Jozef Kozarik
HKHelena Kosnáčová
Helena Kosnáčová
The whole world is currently focused on COVID-19, which causes considerable economic and social damage. The disease is spreading rapidly through the population, and the effort to stop the spread is entirely still failing. In our article, we want to contribute to the improvement of the situation. We propose a tracking system that would identify affected people with greater accuracy than medical staff can. The main goal was to design hardware and construct a device that would track anonymous risky contacts in areas with a highly concentrated population, such as schools, hospitals, large social events, and companies. We have chosen a 2.4 GHz proprietary protocol for contact monitoring and mutual communication of individual devices. The 2.4 GHz proprietary protocol has many advantages such as a low price and higher resistance to interference and thus offers benefits. We conducted a pilot experiment to catch bugs in the system. The device is in the form of a bracelet and captures signals from other bracelets worn at a particular location. In case of contact with an infected person, the alarm is activated. This article describes the concept of the tracking system, the design of the devices, initial tests, and plans for future use.

23 October 2021 in Materials
Verified
Journal Article
Open access
PDF file
LFLucia Feriancová
Lucia Feriancová
IKIveta Kmentová
Iveta Kmentová
MMMichal Micjan
Michal Micjan
MPMilan Pavúk
Milan Pavúk
Martin WeisMartin Weis
Martin Weis
MPMartin Putala
Martin Putala
A series of bithienyl-terminated surfactants with various alkyl chain lengths (from C8 to C13) and phosphono or chlorodimethylsilyl anchoring groups were synthesized by palladium-catalyzed hydrophosphonation, or platinum-catalyzed hydrosilylation as a key step. Surfactants were tested in pentacene or α-sexithiophene-based organic field-effect transistors (OFETs) for the modification of the dielectric surface. The studied surfactants increased the effective mobility of the α-sexithiophene-based device by up to one order of magnitude. The length of alkyl chain showed to be significant for the pentacene-based device, as the effective mobility only increased in the case of dielectric modification with bithienylundecylphosphonic acid. AFM allowed a better understanding of the morphology of semiconductors on bare SiO2 and surfaces treated with bithienylundecylphosphonic acid.

6 December 2021 in Materials
Verified
Journal Article
Open access
PDF file
TVTomas Vincze
Tomas Vincze
MMMichal Micjan
Michal Micjan
JNJuraj Nevrela
Juraj Nevrela
MDMartin Donoval
Martin Donoval
Martin WeisMartin Weis
Martin Weis
Organic field-effect transistors have been envisioned for advanced photodetectors because the organic semiconductors provide unique absorption characteristics, low-cost fabrication, or compatibility with flexible substrates. However, the response time of organic phototransistors still does not reach the required application level. Here, we report the photoresponse of copper phthalocyanine phototransistor in a steady state and under pulsed illumination. The detailed analysis based on the random walk among a field of traps was used to evaluate the dimensionality of electron transport in a device.

23 November 2019 in Technology transfer: fundamental principles and innovative technical solutions
Verified
Journal Article
Open access
PDF file
TDTomas Debnar
Tomas Debnar
PKPeter Kubinec
Peter Kubinec
MMMichal Micjan
Michal Micjan
The aim of this research was to research and verify the possibilities of using microphone to determine mechanical load acting on high voltage insulator. The insulator features a cable hole, which can be used for optical cables. Let’s use this hole as a microphone mount in order to listen to sounds inside of an insulator. The cable hole and the insulator end holes were filled with insulating foam to insulate microphone from the external interferences. Acoustic measurements were performed on the outdoor post insulator C30-850-II. The insulator was placed in bending machine and was repeatedly mechanically stressed by bending forces. The results of this research verify the suitability of the selected method for future use in the proposed device for detection of mechanical overload of high-voltage insulators.