Ulla Kytölä

Ulla Kytölä

Auto-generated profile, based on publicly available information

Ulla Kytölä

Faculty of Built Environment—Concrete and Bridge Structures Tampere University Tampere Finland

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2024 in Structural Concrete
Verified
Journal Article
Open access
TNTarja Nakari
Tarja Nakari
JTJoonas Tulonen
Joonas Tulonen
OAOlli Asp
Olli Asp
UKUlla Kytölä
Ulla Kytölä
ALAnssi Laaksonen
Anssi Laaksonen
The moment redistribution in a continuous prestressed concrete beam occurs as a result of a change in the rigidity of a beam and formation of plastic hinges when approaching the failure. Rotation capacity is required to allow for moment redistribution. Four continuous two‐span concrete beams prestressed with unbonded tendons were built and loaded up to failure at the laboratory of Civil Engineering in Tampere University. The test beams had different reinforcement ratios in the support area when the degree of prestressing and amount of tension reinforcement in the midspans were kept constant. All test beams were loaded by bending, but one test beam had torsion load in addition to bending. The degree of bending moment redistribution was defined by using nonlinear analysis and equations from the European standard and ACI318, as well as the test results. Moment redistribution clearly occurred on all test beams, and the beams had a high level of deformability.

22 June 2021 in Structural Concrete
Verified
Journal Article
Open access
PDF file
UKUlla Kytölä
Ulla Kytölä
OAOlli Asp
Olli Asp
ALAnssi Laaksonen
Anssi Laaksonen
The objective of the current study is to investigate and evaluate the flexural behavior of the continuity connection of precast prestressed concrete beams in negative bending when the tendons are located at the compression side. The experimental program included four T-shaped composite cantilever beams which were loaded up to failure. The main variable of the tests was the amount of prestress force of the connected precast beams. The reinforcement ratio of continuity connection was high. The ultimate flexural capacities and moment-curvature relations were calculated theoretically. A comparison was then carried out between both the experimental and theoretical results. These experiments revealed that prestress force did not influence the ultimate hogging moment capacity of the continuity connection, but it had an effect on its soffit's compression cracking and spalling of the concrete cover before failure. This study also indicated that confinement of the concrete had a massive influence on the connection's behavior, and it increased both its negative moment capacity and ductility.

1 December 2018 in Nordic Concrete Research
Verified
Journal Article
Open access
PDF file
UKUlla Kytölä
Ulla Kytölä
ALAnssi Laaksonen
Anssi Laaksonen
This paper studies restraint moments developing in simple-span precast, prestressed beams made continuous. Methods of evaluating restraint moments produced by creep and differential shrinkage are presented. Shrinkage and creep properties of composite structures, beam and deck parts were tested and compared to values defined according to Eurocode models. Finally, the restraint moments were calculated with both material models for the two-span parking deck structure. The study confirmed the findings of previous studies: that the methods that are used overestimate the negative restraint moment produced by differential shrinkage.

14 December 2021 in Structural Concrete
Verified
Journal Article
Open access
PDF file
UKUlla Kytölä
Ulla Kytölä
JTJoonas Tulonen
Joonas Tulonen
ALAnssi Laaksonen
Anssi Laaksonen
In continuous concrete T‐beams, tension flange plays a remarkable role for the hogging moment capacity at the support area. When precast beams are connected as a continuous structure, longitudinal reinforcement is spread in the flange overhangs at the negative moment area of the continuity connection, which causes longitudinal shear in the tension flange's web‐flange junction. The level of reinforcement spreading influences the magnitude of in‐plane forces at the junction, which can cause the flanges to crack and eventually separate from the web. This separation must be prevented by providing transversal reinforcement in the flanges. Longitudinal shear between web and flange and the required transversal reinforcement are experimentally and computationally studied in cantilever composite T‐beams with the flange in tension. A comparison of the experimental and computational results revealed that longitudinal shear distribution in accordance with conventional beam theory does not always yield safe side results. Analyses made with a particularly drawn truss model and the modified compression field theory are in better agreement with the experimental results.

31 July 2023 in Structural Concrete
Verified
Journal Article
Open access
UKUlla Kytölä
Ulla Kytölä
JTJoonas Tulonen
Joonas Tulonen
OAOlli Asp
Olli Asp
TNTarja Nakari
Tarja Nakari
ALAnssi Laaksonen
Anssi Laaksonen