27 February 2014 in Advanced Materials Research
The aim of this article is to contribute to the summer thermal performance of external timber frame wall by the simultaneous use of experimental measurements and numerical simulations. The measurements were taken on an experimental timber frame passive house. The numerical modeling of the external wall using a dynamic simulation program ANSYS. The results of research are presented and discussed. It is shown that the numerical simulation methods are suitable tools for the prediction of thermal behaviour of light-weight timber-based construction.
1 October 2014 in Advanced Materials Research
The main point of this article is the analysis of the plants influence on the indoor microclimate duality in the passive house, above all the influence on the CO2 concentration. The measurements were made in the experimental passive house in the area of the Faculty of Civil Engineering, VSB – Technical University of Ostrava in the spring months. The volumes of CO2 were analyzed during the many nights, in the room always with two men. In the first was made the measurement without the plants and then during the next measurements were added plants into the referential room which change the CO2 onto oxygen. During the separate measurements were changed quantities of the green parts (of plants) where the photosynthesis change the CO2 onto O2. In the second measurement was the blade area approximately equal to body area of the bigger participant and in the third measurement was the blade area approximately equal to sum of the bodies of both participants of the experiment.
20 April 2015 in Applied Mechanics and Materials
High concentrations of CO2 are one of the causes of imperfect oxygenation of the blood circulation in humans. An experimental measurement of a passive home during a simulated power outage was carried out from July 7-15th 2014. In the measured rooms (one with plants with leaves the size of one of the bigger participants in this project, the second room without any plants at all), the levels of CO2 were observed, as well as the levels of relative air humidity of the interior, and the interior temperature. The measurement was carried out at night, when sleeping time was simulated, i.e. the resting period. The impact of plants did not significantly influence the CO2 reduction in the interior of the building. Regular airing is necessary for maintaining the hygienic limit of the concentration of CO2. It is thus necessary to ensure this with the windows open during an unexpected power outage.
1 October 2014 in Advanced Materials Research
The aim of this article is analysis of energy performance of the timber-frame passive house. The analysis is made on the base of numerical simulation, analytical calculation and experimental measurement. Numerical simulation is solved by the Design Builder software which can determine thermal losses, thermal loads of buildings and other parameters of indoor microclimate - mean radiant temperature, operating temperature and indoor relative humidity, the Predicted Mean Vote (PMV) index, the Predicted Percentage Dissatisfied (PPD) index, concentration CO2 (carbon dioxide). Analytical calculations are solved by the software Simulace. Boundary conditions of the exterior calculation are set with using standard values and the real hour meteorological values (from database of the software Design Builder for Ostrava town and from database of the real experimental measurement values). Experimental measurements of the indoor and exterior parameters (external and indoor air temperature) are realized at the passive timber-frame house of the Research and Innovation Centre of the Moravian-Silesian Wood Cluster in the area of the Faculty of Civil Engineering, VSB – Technical University of Ostrava. Results of theoretical analysis and experimental measurements are compared and evaluated.
27 October 2014 in Advanced Materials Research
The calculation based on the DDFPM method will enable us to identify the percentage engagement of the bivalent source in heating of the facilities in the period under consideration and at the location under consideration and we will be able to verify an optimum design for covering the heat loss by the bivalent source of the heat pump.