Petra Tymová

Petra Tymová

Auto-generated profile, based on publicly available information

Petra Tymová

VSB – Technical University of Ostrava

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 February 2014 in Advanced Materials Research
Verified
Journal Article
Closed access
PDF file
ISIveta Skotnicová
Iveta Skotnicová
ZGZdenek Galda
Zdenek Galda
PTPetra Tymova
Petra Tymova
LLLenka Lausová
Lenka Lausová
The aim of this article is to contribute to the summer thermal performance of external timber frame wall by the simultaneous use of experimental measurements and numerical simulations. The measurements were taken on an experimental timber frame passive house. The numerical modeling of the external wall using a dynamic simulation program ANSYS. The results of research are presented and discussed. It is shown that the numerical simulation methods are suitable tools for the prediction of thermal behaviour of light-weight timber-based construction.

1 October 2014 in Advanced Materials Research
Verified
Journal Article
Closed access
PDF file
ISIveta Skotnicová
Iveta Skotnicová
ZGZdenek Galda
Zdenek Galda
PTPetra Tymova
Petra Tymova
LLLenka Lausová
Lenka Lausová
The aim of this article is analysis of energy performance of the timber-frame passive house. The analysis is made on the base of numerical simulation, analytical calculation and experimental measurement. Numerical simulation is solved by the Design Builder software which can determine thermal losses, thermal loads of buildings and other parameters of indoor microclimate - mean radiant temperature, operating temperature and indoor relative humidity, the Predicted Mean Vote (PMV) index, the Predicted Percentage Dissatisfied (PPD) index, concentration CO2 (carbon dioxide). Analytical calculations are solved by the software Simulace. Boundary conditions of the exterior calculation are set with using standard values and the real hour meteorological values (from database of the software Design Builder for Ostrava town and from database of the real experimental measurement values). Experimental measurements of the indoor and exterior parameters (external and indoor air temperature) are realized at the passive timber-frame house of the Research and Innovation Centre of the Moravian-Silesian Wood Cluster in the area of the Faculty of Civil Engineering, VSB – Technical University of Ostrava. Results of theoretical analysis and experimental measurements are compared and evaluated.


27 October 2014 in Advanced Materials Research
Verified
Journal Article
Closed access
PDF file
ISIveta Skotnicová
Iveta Skotnicová
PTPetra Tymová
Petra Tymová
ZGZdeněk Galda
Zdeněk Galda
LLLenka Lausová
Lenka Lausová
This paper deals with the hygrothermal performance of timber-frame external cladding in a passive house. The wall and roof assemblies were simulated and analyzed with regard to hygrothermal performance. Different boundary conditions and methods were used for the simulation calculations. The results of the simulations were compared with in-situ measurements, which were carried out at an experimental passive house at East Czech Republic. Due to the results of simulations and measurements, it should be possible to evaluate accuracy of simulation methods for prediction of the hygrothermal performance of the lightweight external cladding.

1 January 2011 in Transactions of the VŠB – Technical University of Ostrava, Civil Engineering Series
Verified
Journal Article
Closed access
PDF file
MBMichaela Buršová
Michaela Buršová
ISIveta Skotnicová
Iveta Skotnicová
PTPetra Tymová
Petra Tymová
ZGZdeněk Galda
Zdeněk Galda
Thermal Properties of Buildings in SummerThe topic of this contribution consists of a quality assessment of the interior environments of the selected rooms in the non-production building so as to secure the requirements for thermal stability in summer. Based on theoretical calculations and experimental measurements, the initial state of the interior environment in the rooms was assessed and then suitable measures leading to improvement in interior environment quality were proposed. Simultaneously, a daylight exposure assessment was taken into account and the thermal load of the room was assessed. Tepelně Technické Parametry Staveb v Letním ObdobíObsahem příspěvku je posouzení kvality vnitřního prostředí vybraných místností nevýrobní budovy z hlediska zajištění požadavků na tepelnou stabilitu v letním období. Na základě teoretických výpočtů a experimentálního měřní byl vyhodnocen původní stav vnitřního prostředí místností a následně byla navržena vhodná opatření vedoucí ke zlepšení kvality vnitřního prostředí. Současně bylo zohledněno posouzení denního osvětlení místnosti a zhodnocena tepelná zátěž místnosti.

27 October 2014 in Advanced Materials Research
Verified
Journal Article
Closed access
PDF file
PTPetra Tymová
Petra Tymová
ISIveta Skotnicová
Iveta Skotnicová
ZGZdenek Galda
Zdenek Galda
The calculation based on the DDFPM method will enable us to identify the percentage engagement of the bivalent source in heating of the facilities in the period under consideration and at the location under consideration and we will be able to verify an optimum design for covering the heat loss by the bivalent source of the heat pump.