2 November 2022 in Nature Communications
In radiotherapy for cancer patients, an indispensable process is to delineate organs-at-risk (OARs) and tumors. However, it is the most time-consuming step as manual delineation is always required from radiation oncologists. Herein, we propose a lightweight deep learning framework for radiotherapy treatment planning (RTP), named RTP-Net, to promote an automatic, rapid, and precise initialization of whole-body OARs and tumors. Briefly, the framework implements a cascade coarse-to-fine segmentation, with adaptive module for both small and large organs, and attention mechanisms for organs and boundaries. Our experiments show three merits: 1) Extensively evaluates on 67 delineation tasks on a large-scale dataset of 28,581 cases; 2) Demonstrates comparable or superior accuracy with an average Dice of 0.95; 3) Achieves near real-time delineation in most tasks with <2 s. This framework could be utilized to accelerate the contouring process in the All-in-One radiotherapy scheme, and thus greatly shorten the turnaround time of patients.
1 March 2020 in Radiotherapy and Oncology
Access to healthcare data is indispensable for scientific progress and innovation. Sharing healthcare data is time-consuming and notoriously difficult due to privacy and regulatory concerns. The Personal Health Train (PHT) provides a privacy-by-design infrastructure connecting FAIR (Findable, Accessible, Interoperable, Reusable) data sources and allows distributed data analysis and machine learning. Patient data never leaves a healthcare institute. Lung cancer patient-specific databases (tumor staging and post-treatment survival information) of oncology departments were translated according to a FAIR data model and stored locally in a graph database. Software was installed locally to enable deployment of distributed machine learning algorithms via a central server. Algorithms (MATLAB, code and documentation publicly available) are patient privacy-preserving as only summary statistics and regression coefficients are exchanged with the central server. A logistic regression model to predict post-treatment two-year survival was trained and evaluated by receiver operating characteristic curves (ROC), root mean square prediction error (RMSE) and calibration plots. In 4 months, we connected databases with 23 203 patient cases across 8 healthcare institutes in 5 countries (Amsterdam, Cardiff, Maastricht, Manchester, Nijmegen, Rome, Rotterdam, Shanghai) using the PHT. Summary statistics were computed across databases. A distributed logistic regression model predicting post-treatment two-year survival was trained on 14 810 patients treated between 1978 and 2011 and validated on 8 393 patients treated between 2012 and 2015. The PHT infrastructure demonstrably overcomes patient privacy barriers to healthcare data sharing and enables fast data analyses across multiple institutes from different countries with different regulatory regimens. This infrastructure promotes global evidence-based medicine while prioritizing patient privacy.
2 August 2016 in Radiation Oncology
The aim of this study was to analyze the influence of volumetric changes of bladder and rectum filling on the 3D dose distribution in prostate cancer radiotherapy. A total of 314 cone-beam CT (CBCT) image data sets from 19 patients were enrolled in this study. For each CBCT, the bladder and rectum were contoured and volume sizes were normalized to those on their original CT. The daily delivered dose was recalculated on the CBCT images and the doses to bladder and rectum were investigated. Linear regression analysis was performed to identify the mean dose change of the volume change using SPSS 19. The data show that the variances of the normalized volume of the bladder and the rectum are 0.13–0.58 and 0.12–0.50 respectively. The variances of V70Gy, V60Gy, V50Gy, V40Gy and V30Gy of bladder are bigger than those of rectum for 17 patients. The linear regression analysis indicates a 10 % increase in bladder volume will cause a 5.6 % (±4.9 %) reduction in mean dose (p <0.05). The bladder’s volume change is more significant than that of the rectum for the prostate cancer patient. The rectum volume variations are not significant except for air bubbles, which change the shape and the position of the rectum. The bladder volume variations may cause dose changes proportionately. Monitoring the bladder’s volume before fractional treatment delivery will be crucial for accurate dose delivery.
14 September 2021 in Physics in Medicine & Biology
To investigate the impact of training sample size on the performance of deep learning-based organ auto-segmentation for head-and-neck cancer patients, a total of 1160 patients with head-and-neck cancer who received radiotherapy were enrolled in this study. Patient planning CT images and regions of interest (ROIs) delineation, including the brainstem, spinal cord, eyes, lenses, optic nerves, temporal lobes, parotids, larynx and body, were collected. An evaluation dataset with 200 patients were randomly selected and combined with Dice similarity index to evaluate the model performances. Eleven training datasets with different sample sizes were randomly selected from the remaining 960 patients to form auto-segmentation models. All models used the same data augmentation methods, network structures and training hyperparameters. A performance estimation model of the training sample size based on the inverse power law function was established. Different performance change patterns were found for different organs. Six organs had the best performance with 800 training samples and others achieved their best performance with 600 training samples or 400 samples. The benefit of increasing the size of the training dataset gradually decreased. Compared to the best performance, optic nerves and lenses reached 95% of their best effect at 200, and the other organs reached 95% of their best effect at 40. For the fitting effect of the inverse power law function, the fitted root mean square errors of all ROIs were less than 0.03 (left eye: 0.024, others: <0.01), and the R square of all ROIs except for the body was greater than 0.5. The sample size has a significant impact on the performance of deep learning-based auto-segmentation. The relationship between sample size and performance depends on the inherent characteristics of the organ. In some cases, relatively small samples can achieve satisfactory performance.
5 May 2021 in Frontiers in Oncology
Purpose: While artificial intelligence has shown great promise in organs-at-risk (OARs) auto segmentation for head and neck cancer (HNC) radiotherapy, to reach the level of clinical acceptance of this technology in real-world routine practice is still a challenge. The purpose of this study was to validate a U-net-based full convolutional neural network (CNN) for the automatic delineation of OARs of HNC, focusing on clinical implementation and evaluation. Methods: In the first phase, the CNN was trained on 364 clinical HNC patients’ CT images with annotated contouring from routine clinical cases by different oncologists. The automated delineation accuracy was quantified using the Dice similarity coefficient (DSC) and 95% Hausdorff distance (HD). To assess efficiency, the time required to edit the auto-contours to a clinically acceptable standard was evaluated by a questionnaire. For subjective evaluation, expert oncologists (more than 10 years’ experience) were randomly presented with automated delineations or manual contours of 15 OARs for 30 patient cases. In the second phase, the network was retrained with an additional 300 patients, which were generated by pre-trained CNN and edited by oncologists until to meet clinical acceptance. Results: Based on DSC, the CNN performed best for the spinal cord, brainstem, temporal lobe, eyes, optic nerve, parotid glands and larynx (DSC >0.7). Higher conformity for the OARs delineation was achieved by retraining our architecture, largest DSC improvement on oral cavity (0.53 to 0.93). Compared with the manual delineation time, after using auto-contouring, this duration was significantly shortened from hours to minutes. In the subjective evaluation, two observes showed an apparent inclination on automatic OARs contouring, even for relatively low DSC values. Most of the automated OARs segmentation can reach the clinical acceptance level compared to manual delineations. Conclusions: After retraining, the CNN developed for OARs automated delineation in HNC was proved to be more robust, efficiency and consistency in clinical practice. Deep learning-based auto-segmentation shows great potential to alleviate the labor-intensive contouring of OAR for radiotherapy treatment planning.
11 December 2020 in Physics in Medicine & Biology
Accurate and efficient dose calculation is an important prerequisite to ensure the success of radiation therapy. However, all the dose calculation algorithms commonly used in current clinical practice have to compromise between calculation accuracy and efficiency, which may result in unsatisfactory dose accuracy or highly intensive computation time in many clinical situations. The purpose of this work is to develop a novel dose calculation algorithm based on the deep learning method for radiation therapy. In this study we performed a feasibility investigation on implementing a fast and accurate dose calculation based on a deep learning technique. A two-dimensional (2D) fluence map was first converted into a three-dimensional (3D) volume using ray traversal algorithm. 3D U-Net like deep residual network was then established to learn a mapping between this converted 3D volume, CT and 3D dose distribution. Therefore an indirect relationship was built between a fluence map and its corresponding 3D dose distribution without using significantly complex neural networks. Two hundred patients, including nasopharyngeal, lung, rectum and breast cancer cases, were collected and applied to train the proposed network. Additional 47 patients were randomly selected to evaluate the accuracy of the proposed method through comparing dose distributions, dose volume histograms and clinical indices with the results from a treatment planning system (TPS), which was used as the ground truth in this study. The proposed deep learning based dose calculation algorithm achieved good predictive performance. For 47 tested patients, the average per-voxel bias of the deep learning calculated value and standard deviation (normalized to the prescription), relative to the TPS calculation, is 0.17%±2.28%. The average deep learning calculated values and standard deviations for relevant clinical indices were compared with the TPS calculated results and the t -test p -values demonstrated the consistency between them. In this study we developed a new deep learning based dose calculation method. This approach was evaluated by the clinical cases with different sites. Our results demonstrated its feasibility and reliability and indicated its great potential to improve the efficiency and accuracy of radiation dose calculation for different treatment modalities.