Ian Buchanan

Ian Buchanan

Auto-generated profile, based on publicly available information

Ian Buchanan

Department of Medical Physics and Biomedical Engineering, University College London 1 , Gower Street, London WC1E 6BT, United Kingdom

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 June 2022 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
MEMichela Esposito
Michela Esposito
LMLorenzo Massimi
Lorenzo Massimi
IBIan Buchanan
Ian Buchanan
JFJoseph Ferrara
Joseph Ferrara
Marco EndrizziMarco Endrizzi
Marco Endrizzi
AOAlessandro Olivo
Alessandro Olivo
We report on the development of a low-energy x-ray phase-based microscope using intensity-modulation masks for single-shot retrieval of three contrast channels: transmission, refraction, and ultra-small-angle scattering or dark field. The retrieval method is based on beam tracking, an incoherent and phase-based imaging approach. We demonstrate that the spatial resolution of this imaging system does not depend on focal spot size nor detector pixel pitch, as opposed to conventional and propagation-based x-ray imaging, and it is only dependent on the mask aperture size. This result enables the development of a multi-resolution microscope where multi-scale samples can be explored on different length scales by adjusting only the mask aperture size, without other modifications. Additionally, we show an extended capability of the system to resolve periodic structures below the resolution limit imposed by the mask apertures, which potentially extends dark-field imaging beyond its conventional use.

2 December 2020 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
IBIan Buchanan
Ian Buchanan
GKGibril Kallon
Gibril Kallon
TBThomas Beckenbach
Thomas Beckenbach
JSJoachim Schulz
Joachim Schulz
Marco EndrizziMarco Endrizzi
Marco Endrizzi
AOAlessandro Olivo
Alessandro Olivo
Model refinements for the edge illumination x-ray phase contrast imaging method have been developed to improve simulation accuracy for high energy, polychromatic beams. High-energy x rays are desirable in imaging due to their penetrative power and, for biological samples, their lower dose deposition rate. Accurate models of such scenarios are required for designing appropriate imaging systems and to predict signal strength in complex settings such as clinical imaging or industrial quality assurance. When using optical components appropriate for high-energy x rays in a non-synchrotron setting, system performance was observed to deviate from that predicted by existing models. In this work, experimental data utilizing increasing thicknesses of a known filter material are used to illustrate the limitations of existing models and as validation for the new modeling features. Angular filtration of the cone beam was observed to be the most significant effect; however, specific features of the source and detector are also shown to affect system performance. We conclude by showing that a significantly improved agreement between experimental and simulated data is obtained with the refined model compared to previously existing ones.

27 October 2023 in Applied Physics Reviews
Verified
Journal Article
Open access
PDF file
IBIan Buchanan
Ian Buchanan
Silvia CipicciaSilvia Cipiccia
Silvia Cipiccia
CPCarlo Peiffer
Carlo Peiffer
CNCarlos Navarrete-León
Carlos Navarrete-León
AAAlberto Astolfo
Alberto Astolfo
AOAlessandro Olivo
Alessandro Olivo
X-ray dark-field or ultra-small angle scatter imaging has become increasingly important since the introduction of phase-based x-ray imaging and is having transformative impact in fields such as in vivo lung imaging and explosives detection. Here, we show that dark-field images acquired with the edge-illumination method (either in its traditional double mask or simplified single mask implementation) provide a direct measurement of the scattering function, which is unaffected by system-specific parameters such as the autocorrelation length. We show that this is a consequence both of the specific measurement setup and of the mathematical approach followed to retrieve the dark-field images. We show agreement with theoretical models for datasets acquired both with synchrotron and laboratory x-ray sources. We also introduce a new contrast mechanism, the variance of refraction, which is extracted from the same dataset and provides a direct link with the size of the scattering centers. We show that this can also be described by the same theoretical models. We study the behavior of both signals vs key parameters such as x-ray energy and scatterer radius. We find this allows quantitative and direct scattering measurements during imaging, with implications in all fields where dark-field imaging is used.

6 April 2020 in Optics Express
Verified
Journal Article
Open access
IBIan Buchanan
Ian Buchanan
AMAlberto Mittone
Alberto Mittone
ABAlberto Bravin
Alberto Bravin
PDPaul Claude Diemoz
Paul Claude Diemoz
MEMarco Endrizzi
Marco Endrizzi
AOAlessandro Olivo
Alessandro Olivo
We present data from an implementation of Edge Illumination (EI) that uses a detector aperture designed for increasing dynamic range, suitable for clinically relevant X-ray energies and demonstrated here using synchrotron radiation. By utilising a sufficiently large crosstalk between pixels, this implementation enables single-scan imaging for phase and absorption, and double-scan for phase, absorption and dark field imaging. The presence of the detector mask enables a direct comparison between conventional EI and beam tracking (BT), which we conduct through Monte Carlo and analytical modelling in the case of a single-scan being used for the retrieval of all three contrasts. In the present case, where the X-ray beam width is comparable to the pixel size, we provide an analysis on best-positioning of the beam on the detector for accurate signal retrieval. Further, we demonstrate an application of this method by distinguishing different concentrations of microbubbles via their dark field signals at high energy using an EI system.

17 March 2026 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
MEMichela Esposito
Michela Esposito
AAAlberto Astolfo
Alberto Astolfo
YZYang Zhou
Yang Zhou
IBIan Buchanan
Ian Buchanan
ATAlexei Teplov
Alexei Teplov
AOAlessandro Olivo
Alessandro Olivo
With increasing interest in studying biological systems across spatial scales—from centimeters down to nanometers—histology continues to be the gold standard for tissue imaging at cellular resolution, providing an essential bridge between macroscopic and nanoscopic analysis. However, its inherently destructive and two-dimensional nature limits its ability to capture the full three-dimensional complexity of tissue architecture. Here, we show that phase-contrast X-ray microscopy can enable three-dimensional virtual histology with subcellular resolution. This technique provides direct quantification of electron density without restrictive assumptions, allowing for direct characterization of cellular nuclei in a standard laboratory setting. By combining high spatial resolution and soft tissue contrast, with automated segmentation of cell nuclei, we demonstrated virtual Hematoxylin and Eosin (H&E) staining using machine learning-based style transfer, yielding volumetric datasets compatible with existing histopathological analysis tools. Furthermore, by integrating electron density and the sensitivity to nanometric features of the dark field contrast channel, we achieve stain-free, high-content imaging capable of distinguishing nuclei and extracellular matrix.

24 May 2022 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
LMLorenzo Massimi
Lorenzo Massimi
GKGibril K. Kallon
Gibril K. Kallon
IBIan Buchanan
Ian Buchanan
Marco EndrizziMarco Endrizzi
Marco Endrizzi
PDPiotr Dobrosz
Piotr Dobrosz
AOAlessandro Olivo
Alessandro Olivo
We present a proof-of-concept edge illumination x-ray phase contrast system where the detector mask has been replaced by an indirect conversion detector in which sensitive and insensitive regions have been obtained by “patterning” the scintillator. This was achieved by creating a free-standing grid with period and aperture size matching that of a typical detector mask and filling the apertures with gadolinium oxysulfide. Images of various samples were collected with both the modified and the original edge illumination systems based on the use of two masks to characterize the performances of this detector design. We found that, despite the proof-of-concept nature of this attempt resulting in a structured detector with suboptimal performance, it allows effective separation of the attenuation and refraction channels through phase retrieval and the visualization of hard-to-detect features such as cartilage through the latter channel, thus demonstrating that the proposed approach holds the potential to lead to improved stability since it will use a single optical element facilitating the design of rotating phase contrast systems or the retrofitting of conventional x-ray systems.