Scott K. Nagle

Scott K. Nagle

Auto-generated profile, based on publicly available information

Scott K. Nagle

Department of Medical Physics University of Wisconsin‐Madison Madison Wisconsin USA

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2018 in Journal of Clinical Investigation
Verified
Journal Article
Open access
PDF file
EDEleanor M. Dunican
Eleanor M. Dunican
BEBrett M. Elicker
Brett M. Elicker
DGDavid S. Gierada
David S. Gierada
SNScott K. Nagle
Scott K. Nagle
MSMark L. Schiebler
Mark L. Schiebler
JFJohn V. Fahy
John V. Fahy
BACKGROUND. The link between mucus plugs and airflow obstruction has not been established in chronic severe asthma, and the role of eosinophils and their products in mucus plug formation is unknown. METHODS. In clinical studies, we developed and applied a bronchopulmonary segment–based scoring system to quantify mucus plugs on multidetector computed tomography (MDCT) lung scans from 146 subjects with asthma and 22 controls, and analyzed relationships among mucus plug scores, forced expiratory volume in 1 second (FEV1), and airway eosinophils. Additionally, we used airway mucus gel models to explore whether oxidants generated by eosinophil peroxidase (EPO) oxidize cysteine thiol groups to promote mucus plug formation. RESULTS. Mucus plugs occurred in at least 1 of 20 lung segments in 58% of subjects with asthma and in only 4.5% of controls, and the plugs in subjects with asthma persisted in the same segment for years. A high mucus score (plugs in ≥ 4 segments) occurred in 67% of subjects with asthma with FEV1 of less than 60% of predicted volume, 19% with FEV1 of 60%–80%, and 6% with FEV1 greater than 80% (P < 0.001) and was associated with marked increases in sputum eosinophils and EPO. EPO catalyzed oxidation of thiocyanate and bromide by H2O2 to generate oxidants that crosslink cysteine thiol groups and stiffen thiolated hydrogels. CONCLUSION. Mucus plugs are a plausible mechanism of chronic airflow obstruction in severe asthma, and EPO-generated oxidants may mediate mucus plug formation. We propose an approach for quantifying airway mucus plugging using MDCT lung scans and suggest that treating mucus plugs may improve airflow in chronic severe asthma. TRIAL REGISTRATION. Clinicaltrials.gov NCT01718197, NCT01606826, NCT01750411, NCT01761058, NCT01761630, NCT01759186, NCT01716494, and NCT01760915. FUNDING. NIH grants P01 HL107201, R01 HL080414, U10 HL109146, U10 HL109164, U10 HL109172, U10 HL109086, U10 HL109250, U10 HL109168, U10 HL109257, U10 HL109152, and P01 HL107202 and National Center for Advancing Translational Sciences grants UL1TR0000427, UL1TR000448, and KL2TR000428.

4 December 2012 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
KJKevin M. Johnson
Kevin M. Johnson
SFSean Fain
Sean Fain
MSMark L. Schiebler
Mark L. Schiebler
SNScott Nagle
Scott Nagle
Purpose: To optimize 3D radial ultrashort echo time MRI for high resolution whole‐lung imaging.Methods: 3D radial ultrashort echo time was implemented on a 3T scanner to investigate the effects of: (1) limited field‐of‐view excitation, (2) variable density readouts, and (3) radial oversampling. Improvements in noise performance and spatial resolution were assessed through simulation and phantom studies. Their effects on lung and airway visualization in five healthy male human subjects (mean age 32 years) were compared qualitatively through blinded ordinal scoring by two cardiothoracic radiologists using a nonparametric Friedman test (P < 0.05). Relative signal difference between endobronchial air and adjacent lung tissue, normalized to nearby vessel, was used as a surrogate for lung tissue signal. Quantitative measures were compared using the paired Student's t‐test (P < 0.05). Finally, clinical feasibility was investigated in a patient with interstitial fibrosis.Results: Simulation and phantom studies showed up to 67% improvement in SNR and reduced blurring for short T2* species using all three optimizations. In vivo images showed decreased artifacts and improved lung tissue and airway visualization both qualitatively and quantitatively.Conclusion: The use of limited field‐of‐view excitation, variable readout gradients, and radial oversampling significantly improve the technical quality of 3D radial ultrashort echo time lung images. Magn Reson Med 70:1241–1250, 2013.

15 October 1996 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PBP Blount
P Blount
SSSergei Sukharev
Sergei Sukharev
MSM J Schroeder
M J Schroeder
SNS K Nagle
S K Nagle
CKC Kung
C Kung
MscL is a channel that opens a large pore in the Escherichia coli cytoplasmic membrane in response to mechanical stress. Previously, we highly enriched the MscL protein by using patch clamp as a functional assay and cloned the corresponding gene. The predicted protein contains a largely hydrophobic core spanning two-thirds of the molecule and a more hydrophilic carboxyl terminal tail. Because MscL had no homology to characterized proteins, it was impossible to predict functional regions of the protein by simple inspection. Here, by mutagenesis, we have searched for functionally important regions of this molecule. We show that a short deletion from the amino terminus (3 amino acids), and a larger deletion of 27 amino acids from the carboxyl terminus of this protein, had little if any effect in channel properties. We have thus narrowed the search of the core mechanosensitive mechanism to 106 residues of this 136-amino acid protein. In contrast, single residue substitutions of a lysine in the putative first transmembrane domain or a glutamine in the periplasmic loop caused pronounced shifts in the mechano-sensitivity curves and/or large changes in the kinetics of channel gating, suggesting that the conformational structure in these regions is critical for normal mechanosensitive channel gating.

24 April 2007 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
SSStefan Skare
Stefan Skare
RNRexford D. Newbould
Rexford D. Newbould
DCDavid B. Clayton
David B. Clayton
GAGregory W. Albers
Gregory W. Albers
SNScott Nagle
Scott Nagle
RBRoland Bammer
Roland Bammer
Geometric distortions and poor image resolution are well known shortcomings of single‐shot echo‐planar imaging (ss‐EPI). Yet, due to the motion immunity of ss‐EPI, it remains the most common sequence for diffusion‐weighted imaging (DWI). Moreover, both navigated DW interleaved EPI (iEPI) and parallel imaging (PI) methods, such as sensitivity encoding (SENSE) and generalized autocalibrating parallel acquisitions (GRAPPA), can improve the image quality in EPI. In this work, DW‐EPI accelerated by PI is proposed as a self‐calibrated and unnavigated form of interleaved acquisition. The PI calibration is performed on the b = 0 s/mm2 data and applied to each shot in the rest of the DW data set, followed by magnitude averaging. Central in this study is the comparison of GRAPPA and SENSE in the presence of off‐resonances and motion. The results show that GRAPPA is more robust than SENSE against both off‐resonance and motion‐related artifacts. The SNR efficiency was also investigated, and it is shown that the SNR/scan time ratio is equally high for one‐ to three‐shot high‐resolution diffusion scans due to the shortened EPI readout train length. The image quality improvements without SNR efficiency loss, together with motion tolerance, make the GRAPPA‐driven DW‐EPI sequence clinically attractive. Magn Reson Med 57:881–890, 2007.

1 January 2016 in Radiology
Verified
Journal Article
Closed access
NBNicholas Burris
Nicholas Burris
KJKevin M. Johnson
Kevin M. Johnson
PLPeder E. Z. Larson
Peder E. Z. Larson
MHMichael D. Hope
Michael D. Hope
SNScott K. Nagle
Scott K. Nagle
THThomas A Hope
Thomas A Hope
This pilot study demonstrates that an ultrashort echo time imaging technique is both feasible and sensitive for the detection of small pulmonary nodules in patients with extrapulmonary malignancies who are undergoing hybrid PET/MR imaging. PurposeTo investigate the utility of a free-breathing ultrashort echo time (UTE) sequence for the evaluation of small pulmonary nodules in oncology patients by using a hybrid positron emission tomography (PET)/magnetic resonance (MR) imaging system and to compare the nodule detection rate between UTE and a conventional three-dimensional gradient-recalled-echo (GRE) technique.Materials and MethodsIn this HIPAA-compliant, institutional review board–approved prospective study, 82 pulmonary nodules were identified in eight patients with extrathoracic malignancies. Patients underwent free-breathing UTE and dual-echo three-dimensional GRE imaging of the lungs in a hybrid PET/MR imaging unit immediately after clinical PET/computed tomography (CT). CT was considered the reference standard for nodule detection. Two reviewers identified nodules and obtained measurements on MR images. The McNemar test was used to evaluate differences in nodule detection rate between MR techniques, and interrater agreement was assess...

14 February 2012 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
AFAlex Frydrychowicz
Alex Frydrychowicz
MLMeghan G. Lubner
Meghan G. Lubner
JBJeffrey J. Brown
Jeffrey J. Brown
EMElmar M. Merkle
Elmar M. Merkle
SNScott K. Nagle
Scott K. Nagle
SRScott B. Reeder
Scott B. Reeder
The advent of gadolinium‐based “hepatobiliary” contrast agents offers new opportunities for diagnostic magnetic resonance imaging (MRI) and has triggered great interest for innovative imaging approaches to the liver and bile ducts. In this review article we discuss the imaging properties of the two gadolinium‐based hepatobiliary contrast agents currently available in the U.S., gadobenate dimeglumine and gadoxetic acid, as well as important pharmacokinetic differences that affect their diagnostic performance. We review potential applications, protocol optimization strategies, as well as diagnostic pitfalls. A variety of illustrative case examples will be used to demonstrate the role of these agents in detection and characterization of liver lesions as well as for imaging the biliary system. Changes in MR protocols geared toward optimizing workflow and imaging quality are also discussed. It is our aim that the information provided in this article will facilitate the optimal utilization of these agents and will stimulate the reader's pursuit of new applications for future benefit. J. Magn. Reson. Imaging 2012;35:492‐511.