Bruce Faddegon

Bruce Faddegon

Auto-generated profile, based on publicly available information

Bruce Faddegon

Department of Radiation Oncology, University of California San Francisco, San Francisco, CA 94115, United States of America

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2020 in Physica Medica
Verified
Journal Article
Closed access
BFBruce Faddegon
Bruce Faddegon
JRJose Ramos
Jose Ramos
Jan SchuemannJan Schuemann
Jan Schuemann
AMAimee McNamara
Aimee McNamara
JSJungwook Shin
Jungwook Shin
HPHarald Paganetti
Harald Paganetti

20 September 2019 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
WSWook-Geun Shin
Wook-Geun Shin
JRJose Ramos
Jose Ramos
BFB. Faddegon
B. Faddegon
HTH. N. Tran
H. N. Tran
CVC. Villagrasa
C. Villagrasa
SISebastien Incerti
Sebastien Incerti
This paper presents the influence of electron elastic scattering models, electron thermalization models, and chemical parameters on Geant4-DNA simulations of liquid water radiolysis under mega-electron-volt electron irradiation. The radiochemical yields are simulated using a new Geant4-DNA example. In particular, the influence of the new elastic scattering model recently developed is presented as well as the influence of improved electron thermalization models. The influence of a new chemistry constructor using parameters of another Monte Carlo track structure code is also described. The results calculated using these different models are compared with each other and with experimental data. For sub-mega-electron-volt electron simulations, the combination of the “G4EmDNAPhysics_option2” physics constructor with the recently developed elastic scattering model, the Meesungnoen electron thermalization model, and the “G4EmDNAChemistry_option1” chemistry constructor is recommended.

9 June 2023 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
JDJ Naoki D-Kondo
J Naoki D-Kondo
OGOmar R Garcia-Garcia
Omar R Garcia-Garcia
JLJay A LaVerne
Jay A LaVerne
BFBruce Faddegon
Bruce Faddegon
Jan SchuemannJan Schuemann
Jan Schuemann
JRJose Ramos
Jose Ramos
Objective. The TOPAS-nBio Monte Carlo track structure simulation code, a wrapper of Geant4-DNA, was extended for its use in pulsed and longtime homogeneous chemistry simulations using the Gillespie algorithm. Approach. Three different tests were used to assess the reliability of the implementation and its ability to accurately reproduce published experimental results: (1) a simple model with a known analytical solution, (2) the temporal evolution of chemical yields during the homogeneous chemistry stage, and (3) radiolysis simulations conducted in pure water with dissolved oxygen at concentrations ranging from 10 μM to 1 mM with [H2O2] yields calculated for 100 MeV protons at conventional and FLASH dose rates of 0.286 Gy s−1 and 500 Gy s−1, respectively. Simulated chemical yield results were compared closely with data calculated using the Kinetiscope software which also employs the Gillespie algorithm. Main results. Validation results in the third test agreed with experimental data of similar dose rates and oxygen concentrations within one standard deviation, with a maximum of 1% difference for both conventional and FLASH dose rates. In conclusion, the new implementation of TOPAS-nBio for the homogeneous long time chemistry simulation was capable of recreating the chemical evolution of the reactive intermediates that follow water radiolysis. Significance. Thus, TOPAS-nBio provides a reliable all-in-one chemistry simulation of the physical, physico-chemical, non-homogeneous, and homogeneous chemistry and could be of use for the study of FLASH dose rate effects on radiation chemistry.

14 August 2023 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
BFBruce Faddegon
Bruce Faddegon
EBEleanor A Blakely
Eleanor A Blakely
LBLucas Burigo
Lucas Burigo
YCYair Censor
Yair Censor
IDIvana Dokic
Ivana Dokic
RSReinhard W Schulte
Reinhard W Schulte
Objective . To propose a mathematical model for applying ionization detail (ID), the detailed spatial distribution of ionization along a particle track, to proton and ion beam radiotherapy treatment planning (RTP). Approach . Our model provides for selection of preferred ID parameters ( I p ) for RTP, that associate closest to biological effects. Cluster dose is proposed to bridge the large gap between nanoscopic I p and macroscopic RTP. Selection of I p is demonstrated using published cell survival measurements for protons through argon, comparing results for nineteen I p : N k , k = 2, 3, …, 10, the number of ionizations in clusters of k or more per particle, and F k , k = 1, 2, …, 10, the number of clusters of k or more per particle. We then describe application of the model to ID-based RTP and propose a path to clinical translation. Main results . The preferred I p were N 4 and F 5 for aerobic cells, N 5 and F 7 for hypoxic cells. Significant differences were found in cell survival for beams having the same LET or the preferred N k . Conversely, there was no significant difference for F 5 for aerobic cells and F 7 for hypoxic cells, regardless of ion beam atomic number or energy. Further, cells irradiated with the same cluster dose for these I p had the same cell survival. Based on these preliminary results and other compelling results in nanodosimetry, it is reasonable to assert that I p exist that are more closely associated with biological effects than current LET-based approaches and microdosimetric RBE-based models used in particle RTP. However, more biological variables such as cell line and cycle phase, as well as ion beam pulse structure and rate still need investigation. Significance . Our model provides a practical means to select preferred I p from radiobiological data, and to convert I p to the macroscopic cluster dose for particle RTP.

21 February 2025 in Medical Physics
Verified
Journal Article
Open access
PAPedro Arce
Pedro Arce
JAJay W. Archer
Jay W. Archer
LALorenzo Arsini
Lorenzo Arsini
ABAlexander Bagulya
Alexander Bagulya
DBDavid Bolst
David Bolst
DWDennis H. Wright
Dennis H. Wright
Background: Geant4, a Monte Carlo Simulation Toolkit extensively used in bio‐medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community. In 2014, the G4‐Med benchmarking system was born from the effort of the Geant4 Medical Simulation Benchmarking Group, to benchmark and monitor the evolution of Geant4 for medical physics applications. The G4‐Med system was first described in our Medical Physics Special Report published in 2021. Results of the tests were reported for Geant4 10.5. Purpose: In this work, we describe the evolution of the G4‐Med benchmarking system. Methods: The G4‐Med benchmarking suite currently includes 23 tests, which benchmark Geant4 from the calculation of basic physical quantities to the simulation of more clinically relevant set‐ups. New tests concern the benchmarking of Geant4‐DNA physics and chemistry components for regression testing purposes, dosimetry for brachytherapy with a source, dosimetry for external x‐ray and electron FLASH radiotherapy, experimental microdosimetry for proton therapy, and in vivo PET for carbon and oxygen beams. Regression testing has been performed between Geant4 10.5 and 11.1. Finally, a simple Geant4 simulation has been developed and used to compare Geant4 EM physics constructors and physics lists in terms of execution times. Results: In summary, our EM tests show that the parameters of the multiple scattering in the Geant4 EM constructor G4EmStandardPhysics_option3 in Geant4 11.1, while improving the modeling of the electron backscattering in high atomic number targets, are not adequate for dosimetry for clinical x‐ray and electron beams. Therefore, these parameters have been reverted back to those of Geant4 10.5 in Geant4 11.2.1. The x‐ray radiotherapy test shows significant differences in the modeling of the bremsstrahlung process, especially between G4EmPenelopePhysics and the other constructors under study ( G4EmLivermorePhysics , G4EmStandardPhysics_option3 , and G4EmStandardPhysics_option4 ). These differences will be studied in an in‐depth investigation within our Group. Improvement in Geant4 11.1 has been observed for the modeling of the proton and carbon ion Bragg peak with energies of clinical interest, thanks to the adoption of ICRU90 to calculate the low energy proton stopping powers in water and of the Linhard–Sorensen ion model, available in Geant4 since version 11.0. Nuclear fragmentation tests of interest for carbon ion therapy show differences between Geant4 10.5 and 11.1 in terms of fragment yields. In particular, a higher production of boron fragments is observed with Geant4 11.1, leading to a better agreement with reference data for this fragment. Conclusions: Based on the overall results of our tests, we recommend to use G4EmStandardPhysics_option4 as EM constructor and QGSP_BIC_HP with G4EmStandardPhysics_option4 , for hadrontherapy applications. The Geant4‐DNA physics lists report differences in modeling electron interactions in water, however, the tests have a pure regression testing purpose so no recommendation can be formulated.

8 July 2022 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
JRJose Ramos
Jose Ramos
OGOmar García-García
Omar García-García
JDJorge Domínguez-Kondo
Jorge Domínguez-Kondo
JLJay A LaVerne
Jay A LaVerne
Jan SchuemannJan Schuemann
Jan Schuemann
BFBruce Faddegon
Bruce Faddegon
Current Monte Carlo simulations of DNA damage have been reported only at ambient temperature. The aim of this work is to use TOPAS-nBio to simulate the yields of DNA single-strand breaks (SSBs) and double-strand breaks (DSBs) produced in plasmids under low-LET irradiation incorporating the effect of the temperature changes in the environment. A new feature was implemented in TOPAS-nBio to incorporate reaction rates used in the simulation of the chemical stage of water radiolysis as a function of temperature. The implemented feature was verified by simulating temperature-dependent G -values of chemical species in liquid water from 20 °C to 90 °C. For radiobiology applications, temperature dependent SSB and DSB yields were calculated from 0 °C to 42 °C, the range of available published measured data. For that, supercoiled DNA plasmids dissolved in aerated solutions containing EDTA irradiated by Cobalt-60 gamma-rays were simulated. TOPAS-nBio well reproduced published temperature-dependent G -values in liquid water and the yields of SSB and DSB for the temperature range considered. For strand break simulations, the model shows that the yield of SSB and DSB increased linearly with the temperature at a rate of (2.94 ± 0.17) × 10 −10 Gy –1 Da –1 °C –1 ( R 2 = 0.99) and (0.13 ± 0.01) × 10 −10 Gy –1 Da –1 °C –1 ( R 2 = 0.99), respectively. The extended capability of TOPAS-nBio is a complementary tool to simulate realistic conditions for a large range of environmental temperatures, allowing refined investigations of the biological effects of radiation.