Linran Zhao

Linran Zhao

Auto-generated profile, based on publicly available information

Linran Zhao

Chandra Family Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, TX, USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 March 2024 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
LZLinran Zhao
Linran Zhao
RSRaymond G. Stephany
Raymond G. Stephany
YHYiming Han
Yiming Han
PAParvez Ahmmed
Parvez Ahmmed
THTzu-Ping Huang
Tzu-Ping Huang
Yaoyao JiaYaoyao Jia
Yaoyao Jia
Utilizing injectable devices for monitoring animal health offers several advantages over traditional wearable devices, including improved signal-to-noise ratio (SNR) and enhanced immunity to motion artifacts. We present a wireless application-specific integrated circuit (ASIC) for injectable devices. The ASIC has multiple physiological sensing modalities including body temperature monitoring, electrocardiography (ECG), and photoplethysmography (PPG). The ASIC fabricated using the CMOS 180 nm process is sized to fit into an injectable microchip implant. The ASIC features a low-power design, drawing an average DC power of 155.3 μW, enabling the ASIC to be wirelessly powered through an inductive link. To capture the ECG signal, we designed the ECG analog frontend (AFE) with 0.3 Hz low cut-off frequency and 45-79 dB adjustable midband gain. To measure PPG, we employ an energy-efficient and safe switched-capacitor-based (SC) light emitting diode (LED) driver to illuminate an LED with milliampere-level current pulses. A SC integrator-based AFE converts the current of photodiode with a programmable transimpedance gain. A resistor-based Wheatstone Bridge (WhB) temperature sensor followed by an instrumentation amplifier (IA) provides 27–47 °C sensing range with 0.02 °C inaccuracy. Recorded physiological signals are sequentially sampled and quantized by a 10-bit analog-to-digital converter (ADC) with the successive approximation register (SAR) architecture. The SAR ADC features an energy-efficient switching scheme and achieves a 57.5 dB signal-to-noise-and-distortion ratio (SNDR) within 1 kHz bandwidth. Then, a back data telemetry transmits the baseband data via a backscatter scheme with intermediate-frequency assistance. The ASIC’s overall functionality and performance has been evaluated through an in vivo experiment.

7 May 2024 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
YHYiming Han
Yiming Han
LZLinran Zhao
Linran Zhao
RSRaymond G. Stephany
Raymond G. Stephany
JHJu-Chun Hsieh
Ju-Chun Hsieh
HWHuiliang Wang
Huiliang Wang
Yaoyao JiaYaoyao Jia
Yaoyao Jia
This paper introduces a wirelessly powered scattered neural recording wearable system that can facilitate continuous, untethered, and long-term electroencephalogram (EEG) recording. The proposed system, including 32 standalone EEG recording devices and a central controller, is incorporated in a wearable form factor. The standalone devices are sparsely distributed on the scalp, allowing for flexible placement and varying quantities to provide extensive spatial coverage and scalability. Each standalone device featuring a low-power EEG recording application-specific integrated circuit (ASIC) wirelessly receives power through a 60 MHz inductive link. The low-power ASIC design (84.6 μW) ensures sufficient wireless power reception through a small receiver (Rx) coil. The 60 MHz inductive link also serves as the data carrier for wireless communication between standalone devices and the central controller, eliminating the need for additional data antennas. All these efforts contribute to the miniaturization of standalone devices with dimensions of 12×12×5 mm 3 , enhancing device wearability. The central controller applies the pulse width modulation (PWM) scheme on the 60 MHz carrier, transmitting user commands at 4 Mbps to EEG recording ASICs. The ASIC employs a novel synchronized PWM demodulator to extract user commands, operating signal digitization and data transmission. The analog frontend (AFE) amplifies the EEG signal with a gain of 45 dB and applies band-pass filtering from 0.03 Hz to 400 Hz, with an input-referred noise (IRN) of 3.62 μV RMS . The amplified EEG signal is then digitized by a 10-bit successive approximation register (SAR) analog-to-digital converter (ADC) with a peak signal-to-noise and distortion ratio (SNDR) of 55.4 dB. The resulting EEG data is transmitted to an external software-defined radio (SDR) Rx through load-shift-keying (LSK) backscatter at 3.75 Mbps. The system’s functionality is fully evaluated in human experiments.

26 March 2023
Verified
Conference Paper
Open access
ABAhmet F. Budak
Ahmet F. Budak
KZKeren Zhu
Keren Zhu
HCHao Chen
Hao Chen
SPSouradip Poddar
Souradip Poddar
LZLinran Zhao
Linran Zhao
DPDavid Z. Pan
David Z. Pan
Recent advances in analog device sizing algorithms show promising results on the automatic schematic design. However, the majority of the sizing algorithms are based on schematic-level simulations and layout-agnostic. The physical layout implementation brings extra parasitics to the analog circuits, leading to discrepancies between schematic and post-layout performance. This performance gap raises questions about the effectiveness of automatic analog device sizing tools. Prior work has leveraged procedural layout generation to account for layout-induced parasitics in the sizing process. However, the need for layout templates makes such methodology limited in application. In this paper, we propose to bridge automatic analog sizing with post-layout performance using state-of-the-art optimization-based analog layout generators. A quantitative study is conducted to measure the impact of layout awareness in state-of-the-art device sizing algorithms. Furthermore, we present our perspectives on the future directions in layout-aware analog circuit schematic design.

29 January 2025 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
LZLinran Zhao
Linran Zhao
YGYan Gong
Yan Gong
XLXiang Liu
Xiang Liu
WSWei Shi
Wei Shi
YHYiming Han
Yiming Han
Yaoyao JiaYaoyao Jia
Yaoyao Jia
This article presents the creation of a wireless, miniature implantable opto-electro neural interface device called NeuroFlare, capable of simultaneous neural recording and optical stimulation. NeuroFlare features a low-power, dual-modal application-specific integrated circuit (ASIC) fabricated using the 180-nm CMOS process. To support the power-intensive optical stimulation in NeuroFlare, the ASIC employs a novel linear-charging switched-capacitor stimulation (LC-SCS) structure. The LC-SCS, operating under only a 1.2-V supply voltage, can illuminate the LED with a driving voltage three times the supply voltage and large current pulses of up to 12 mA while maintaining a high charging efficiency of 86.4%. In addition, LC -SCS requires only one off-chip capacitor, greatly facilitating device miniaturization. To accurately record neural signals in the presence of stimulation artifacts, the ASIC employs a delta-sigma modulator ( $\Delta \Sigma $ M)-based recording front end with a wide dynamic range (DR) to directly digitize the neural signals. The $\Delta \Sigma $ M features a 2nd-order loop architecture implemented using a linearized transconductance-capacitor (Gm-C) integrator followed by an active noise-shaping (NS) successive approximation register (SAR) quantizer. The $\Delta \Sigma $ M with a power consumption of $9.8~{\mu }$ W provides a peak DR of 83.7 dB, corresponding to a 400-mVPP linear input range. The $\Delta \Sigma $ M’s 173.8-dB figure of merit (FoMDR) indicates its superior energy efficiency. The ASIC is assembled into a prototype of NeuroFlare measuring $2.8 \,\, {\times } \,\, 3.5 \,\, {\times } \,\, 0.7$ mm3. The recorded light-evoked local field potential (LFP) verified the functionality of NeuroFlare in vivo.

16 November 2023 in IEEE Solid-State Circuits Magazine
Verified
Journal Article
Closed access
Yaoyao JiaYaoyao Jia
Yaoyao Jia
LZLinran Zhao
Linran Zhao
Since the development of the first cardiac pacemaker implant in 1958 [1] , implantable medical devices (IMDs) have assumed a critical role across a broad spectrum of clinical applications [2] , [3] , [4] , [5] . These innovative devices facilitate diagnosis, deliver therapeutic interventions, and promote regenerative processes. Examples abound, from the widely recognized deep brain stimulator to drug delivery systems, vital sign monitoring devices, and cochlear implants. In addition, the significance of IMDs extends into the realm of research, where they have revolutionized scientific approaches and methodologies, particularly in behavioral neuroscience. Cutting-edge IMDs designed for neural interfaces can support advanced neural stimulation and neural recording. Such neural interface IMDs have made significant contributions to deepening our fundamental understanding of brain functions and advancing the development of therapies for various brain injuries and disorders, such as dystonia, depression, and Parkinson’s disease [6] , [7] , [8] .

11 November 2024 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
LZLinran Zhao
Linran Zhao
YGYan Gong
Yan Gong
RSRaymond G. Stephany
Raymond G. Stephany
WSWei Shi
Wei Shi
WLWen Li
Wen Li
Yaoyao JiaYaoyao Jia
Yaoyao Jia
This paper presents an application-specific integrated circuit (ASIC) fabricated using the CMOS 180 nm process to perform simultaneous neural recording and optogenetic stimulation. To perform effective optogenetic stimulation, the ASIC features an advanced switched-capacitor-based stimulation (SCS) driver, called voltage-boosting SCS (VB-SCS). The VB-SCS can drive LED with large current pulses up to 8 mA while reducing the required supply voltage by half, facilitating wireless power reception. To prevent saturation from stimulation-induced artifacts, the ASIC integrates a direct digitizing recording frontend with a high-resolution delta-sigma (ΔΣ) analog-to-digital converter (ADC) that directly digitizes neural signals with a large input dynamic range. This ΔΣ ADC involves a Gm-C integrator followed by a noise-shaping (NS) successive approximation register (SAR) quantizer. Measurement results indicate that this ΔΣ ADC-based direct digitizing frontend can tolerate large artifacts up to 300 mV PP while linearly digitizing neural signals with an effective number of bits (ENOB) of 11.4 bits, consuming 10.8 μW. The ASIC, together with its associated passive components, was assembled into a headstage for in vivo verification, successfully demonstrating the functionality of the ASIC.