Kenneth J. Gustafson

Kenneth J. Gustafson

Auto-generated profile, based on publicly available information

Kenneth J. Gustafson

Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2014 in Physical Medicine and Rehabilitation Clinics of North America
Verified
Journal Article
Closed access
CHChester Ho
Chester Ho
RTRonald Triolo
Ronald Triolo
AEAnastasia Leila Elias
Anastasia Leila Elias
KKKevin L. Kilgore
Kevin L. Kilgore
ADAnthony F. DiMarco
Anthony F. DiMarco
VMVivian K Mushahwar
Vivian K Mushahwar

1 December 2008 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
YGYanina Grinberg
Yanina Grinberg
MSMatthew A. Schiefer
Matthew A. Schiefer
DTDustin J. Tyler
Dustin J. Tyler
KGKenneth J. Gustafson
Kenneth J. Gustafson
The number of applications using neural prosthetic interfaces is expanding. Computer models are a valuable tool to evaluate stimulation techniques and electrode designs. Although our understanding of neural anatomy has improved, its impact on the effects of neural stimulation is not well understood. This study evaluated the effects of fascicle perineurial thickness, diameter, and position on axonal excitation thresholds and population recruitment using finite element models and NEURON simulations. The perineurial thickness of human fascicles was found to be 3.0% plusmn 1.0% of the fascicle diameter. Increased perineurial thickness and fascicle diameter increased activation thresholds. The presence of a large neighboring fascicle caused a significant change in activation of a smaller target fascicle by as much as 80% plusmn 11% of the total axon population. Smaller fascicles were recruited at lower amplitudes than neighboring larger fascicles. These effects were further illustrated in a realistic model of a human femoral nerve surrounded by a nerve cuff electrode. The data suggest that fascicular selectivity is strongly dependent upon the anatomy of the nerve being stimulated. Therefore, accurate representations of nerve anatomy are required to develop more accurate computer models to evaluate and optimize nerve electrode designs for neural prosthesis applications.

1 January 2009 in Journal of Rehabilitation Research and Development
Verified
Journal Article
Closed access
KGKenneth J. Gustafson
Kenneth J. Gustafson
GPGilles C. J. Pinault
Gilles C. J. Pinault
JNJennifer J. Neville
Jennifer J. Neville
ISIshaq Syed
Ishaq Syed
JJJohn A. Davis Jr
John A. Davis Jr
RTRonald J. Triolo
Ronald J. Triolo
Clinical interventions to restore standing or stepping by using nerve cuff stimulation require a detailed knowledge of femoral nerve neuroanatomy. We harvested eight femoral nerves with all distal branches and characterized the branching patterns and diameters. The fascicular representation of each distal nerve was identified and traced proximally to create fascicle maps of the compound femoral nerve in four cadaver specimens. Distal nerves were consistently represented as individual fascicles or distinct groups of fascicles in the compound femoral nerve. Branch-free length of the compound femoral nerve was 1.50 +/- 0.47 cm (mean +/- standard deviation). Compound femoral nerve cross sections were noncircular with major and minor diameters of 10.50 +/- 1.52 mm and 2.30 +/- 0.63 mm, respectively. In vivo intraoperative measurements in six subjects were consistent with cadaver results. Selective stimulation of individual muscles innervated by the femoral nerve may therefore be possible with a single neural prosthesis able to selectively stimulate individual groups of fascicles.

1 January 2012 in Journal of Rehabilitation Research and Development
Verified
Journal Article
Closed access
KGKenneth J. Gustafson
Kenneth J. Gustafson
YGYanina Grinberg
Yanina Grinberg
SJSheeba Joseph
Sheeba Joseph
RTRonald J. Triolo
Ronald J. Triolo
The design of neural prostheses to restore standing balance, prevent foot drop, or provide active propulsion during ambulation requires detailed knowledge of the distal sciatic nerve anatomy. Three complete sciatic nerves and branches were dissected from the piriformis to each muscle entry point to characterize the branching patterns and diameters. Fascicle maps were created from serial sections of each distal terminus below the knee through the anastomosis of the tibial and common fibular nerves above the knee. Similar branching patterns and fascicle maps were observed across specimens. Fascicles innervating primary plantar flexors, dorsiflexors, invertors, and evertors were distinctly separate and functionally organized in the proximal tibial, common fibular, and distal sciatic nerves; however, fascicles from individual muscles were not apparent at these levels. The fascicular organization is conducive to selective stimulation for isolated and/or balanced dorsiflexion, plantar flexion, eversion, and inversion through a single multicontact nerve-cuff electrode. These neuroanatomical data are being used to design nerve-cuff electrodes for selective control of ankle movement and improve current lower-limb neural prostheses.

7 December 2005 in World Journal of Urology
Verified
Journal Article
Closed access
PDF file
KGKenneth J. Gustafson
Kenneth J. Gustafson
PZPaul F. Zelkovic
Paul F. Zelkovic
AFAdrian H. Feng
Adrian H. Feng
CDChristine E. Draper
Christine E. Draper
DBDonald R. Bodner
Donald R. Bodner
WGWarren M. Grill
Warren M. Grill

3 April 2008 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
TBTim M. Bruns
Tim M. Bruns
NBNarendra Bhadra
Narendra Bhadra
KGKenneth J. Gustafson
Kenneth J. Gustafson
We evaluated variable patterns of pudendal nerve (PN) stimuli for reflex bladder excitation. Reflex activation of the bladder has been demonstrated previously with 20-33 Hz continuous stimulation of PN afferents. Neuronal circuits accessed by afferent mediated pathways may respond better to physiological patterned stimuli than continuous stimulation. Unilateral PN nerve cuffs were placed in neurologically intact male cats. PN stimulation (0.5-100 Hz) was performed under isovolumetric conditions at bladder volumes up to the occurrence of distension evoked reflex contractions. Stimulus evoked reflex bladder contractions were elicited in eight cats. Across all experiments, bursting of 2-10 pulses at 100-200 Hz repeated at continuous stimulation frequencies evoked significantly larger bladder responses than continuous (single pulse) stimulation (52.0 plusmn 44.5%). Bladder excitation was also effective at 1 Hz continuous stimuli, which is lower than typically reported. Variable patterned pulse bursting resulted in greater evoked reflex bladder pressures and increased the potential stimulation parameter space for effective bladder excitation. Improved bladder excitation should increase the efficacy of neuroprostheses for bladder control.