Andrea Zonnino

Andrea Zonnino

Auto-generated profile, based on publicly available information

Andrea Zonnino

University of Delaware

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 April 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
AZAndrea Zonnino
Andrea Zonnino
FSFabrizio Sergi
Fabrizio Sergi
Objective: Several forward dynamics estimation approaches have been proposed to estimate individual muscle force. However, characterization of the estimation error that arises when measurements are available only from a subset of the muscles involved in the movement under analysis, as it is the case of the forearm muscles, has been limited. Our objectives were: 1) to quantify the accuracy of forward-dynamics muscle force estimators for forearm muscles; 2) to develop a muscle force estimator that is accurate even when measurements are available only from a subset of muscles acting on a given joint or segment. Methods: We developed a neuromusculoskeletal (NMSK) estimator that integrates forward dynamics estimation with a neural model of muscle co-contraction to estimate individual muscle force during isometric contractions, suitable to operate when measurements are not available for all muscles. We developed a computational framework to assess the effect of physiological variability in muscle co-contraction, cross-talk, and measurement error on the estimator accuracy using a sensitivity analysis. We thus compared the performance of our estimator with the performance of a standard estimator that neglects the contribution of unmeasured muscles. Results: The NMSK estimator reduces the estimation error by 25% in average noise conditions. Moreover, the NMSK estimator is robust against physiological variability in muscle co-contraction and outperforms the standard estimator even when the validity of the neural model is compromised. Conclusion and Significance: In isometric tasks, the NMSK estimator reduces muscle force estimation error compared to a standard estimator, and may enable future applications involving estimation of forearm muscle force during coordinated movements.

1 June 2019
Verified
Conference Paper
Closed access
AZAndrea Zonnino
Andrea Zonnino
DSDaniel R. Smith
Daniel R. Smith
PDPeyton L. Delgorio
Peyton L. Delgorio
CJCurtis L. Johnson
Curtis L. Johnson
FSFabrizio Sergi
Fabrizio Sergi
Non-invasive in-vivo measurement of individual muscle force is limited by the infeasibility of placing force sensing elements in series with the musculo-tendon structures. While different methods based either on shear wave elastography or electromyography have been recently proposed to non-invasively estimate individual muscle forces, they can only be used to quantity forces in a limited set of superficial muscles. As such, they are not suitable to study the neuromuscular control of movements that require coordinated action of multiple muscles. In this work, we present multi-muscle magnetic resonance elastography (MM-MRE), a new technique capable of quantifying force for each muscle in the forearm, thus enabling the study of the neuromuscular control of wrist movements. To quantity individual muscle force, MM-MRE integrates measurements of joint torque provided by an MRI-compatible instrumented handle with muscle-specific measurements of shear wave speed obtained via MRE into a forward dynamic muscle force estimator based on a realistic musculoskeletal model of the forearm. A single-subject pilot experiment demonstrates the possibility of obtaining measurements from individual muscles and establishes that MM-MRE has sufficient sensitivity to detect changes in the muscle specific measurement of shear-wave speed following the application of isometric flexion and extension torques with self-selected intensity.

6 June 2023 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
DSDaniel R. Smith
Daniel R. Smith
CHCody A. Helm
Cody A. Helm
AZAndrea Zonnino
Andrea Zonnino
MMMatthew D.J. McGarry
Matthew D.J. McGarry
CJCurtis L Johnson
Curtis L Johnson
FSFabrizio Sergi
Fabrizio Sergi
Objective: To establish the sensitivity of magnetic resonance elastography (MRE) to active muscle contraction in multiple muscles of the forearm. Methods: We combined MRE of forearm muscles with an MRI-compatible device, the MREbot, to simultaneously measure the mechanical properties of tissues in the forearm and the torque applied by the wrist joint during isometric tasks. We measured shear wave speed of thirteen forearm muscles via MRE in a series of contractile states and wrist postures and fit these outputs to a force estimation algorithm based on a musculoskeletal model. Results: Shear wave speed changed significantly upon several factors, including whether the muscle was recruited as an agonist or antagonist (p = 0.0019), torque amplitude (p = <0.0001), and wrist posture (p = 0.0002). Shear wave speed increased significantly during both agonist (p = <0.0001) and antagonist (p = 0.0448) contraction. Additionally, there was a greater increase in shear wave speed at greater levels of loading. The variations due to these factors indicate the sensitivity to functional loading of muscle. Under the assumption of a quadratic relationship between shear wave speed and muscle force, MRE measurements accounted for an average of 70% of the variance in the measured joint torque. Conclusion: This study shows the ability of MM-MRE to capture variations in individual muscle shear wave speed due to muscle activation and presents a method to estimate individual muscle force through MM-MRE derived measurements of shear wave speed. Significance: MM-MRE could be used to establish normal and abnormal muscle co-contraction patterns in muscles of the forearm controlling hand and wrist function.

27 February 2019 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
AZAndrea Zonnino
Andrea Zonnino
FSFabrizio Sergi
Fabrizio Sergi
The control of joint stiffness is a fundamental mechanism used to control human movements. While many studies have observed how stiffness is modulated for tasks involving shoulder and elbow motion, a limited amount of knowledge is available for wrist movements, though the wrist plays a crucial role in manipulation. We have developed a computational framework based on a realistic musculoskeletal model, which allows one to calculate the passive and active components of the wrist joint stiffness. We first used the framework to validate the musculoskeletal model against experimental measurements of the wrist joint stiffness, and then to study the contribution of different muscle groups to the passive joint stiffness. We finally used the framework to study the effect of muscle cocontraction on the active joint stiffness. The results show that thumb and finger muscles play a crucial role in determining the passive wrist joint stiffness: in the neutral posture, the direction of maximum stiffness aligns with the experimental measurements, and the magnitude increases by 113% when they are included. Moreover, the analysis of the controllability of joint stiffness showed that muscle cocontraction positively correlates with the stiffness magnitude and negatively correlates with the variability of the stiffness orientation (p < 0.01 in both cases). Finally, an exhaustive search showed that with appropriate selection of a muscle activation strategy, the joint stiffness orientation can be arbitrarily modulated. This observation suggests the absence of biomechanical constraints on the controllability of the orientation of the wrist joint stiffness.

27 October 2021 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
HCHaider A. Chishty
Haider A. Chishty
AZAndrea Zonnino
Andrea Zonnino
AFAndria Farrens
Andria Farrens
FSFabrizio Sergi
Fabrizio Sergi
We present the UDiffWrist (UDW), a low-impedance 2-DOF wrist exoskeleton featuring a cable-differential transmission. To investigate the effect of different design strategies for achieving kinematic compatibility, we developed two versions of this robot: One version (UDW-C) achieves kinematic compatibility only in the case of perfect alignment between human and robot joints. The second version (UDW-NC) connects the human and robot via passive joints to achieve kinematic compatibility regardless of alignment between human and robot joints. Through characterization experiments, we found that the UDW-NC was more robust to misalignments than the UDW-C: the increase in maximum interaction torque associated with misalignments was greater for the UDW-C than the UDW-NC robot (p = 0.003). However, the UDW-NC displayed greater Coulomb friction (p < 0.001). Further, Coulomb friction increased more for the UDW-NC than the UDW-C in the presence of misalignments between the human and robot axes (p < 0.001). We also found that torque transfer was more accurate in the UDW-C than in the UDW-NC. These results suggest that for the small (10 deg) 2-DOF wrist movements considered, the advantages of the UDW-NC in terms of kinematic compatibility are likely overshadowed by the negative effects in friction and torque transfer accuracy.

20 March 2019 in bioRxiv
Verified
Preprint
Open access
PDF file
AZAndrea Zonnino
Andrea Zonnino
AFAndria Farrens
Andria Farrens
DRDavid Ress
David Ress
FSFabrizio Sergi
Fabrizio Sergi
Increased reticulospinal (RS) function has been observed to cause both positive and negative outcomes in the recovery of motor function after corticospinal lesions such as stroke. Current knowledge of RF function is limited by the lack of accurate, noninvasive methods for measuring RS function. Recent studies suggest that the RS tract may be involved in processing and generating Long Latency Responses (LLRs). LLRs, elicited by applying precisely controlled perturbations, can act as a reliable stimulus to measure LLR-related brainstem function using fMRI with high signal-to-noise ratio. In this paper, we present StretchfMRI, a new technique that enables simultaneous recording of neural and muscular activity during motor responses conditioned by velocity-controlled robotic perturbations, which allows for direct investigation of the neural correlates of LLRs using fMRI. Via preliminary validation experiments, we demonstrate that our technique can reliably elicit and identify LLRs in two wrist muscles–FCR and ECU. Moreover, via a single-subject pilot experiment, we show that the occurrence of an LLR in a flexor and extensor muscle modulates neural activity in distinct regions of the brainstem. The observed somatotopic organization is in agreement with the double reciprocal model of RS function observed in animal models, in which the right medullary and left pontine reticular formation are responsible for control of the motor activity in flexors and extensors, respectively.