Haider A. Chishty

Haider A. Chishty

Auto-generated profile, based on publicly available information

Haider A. Chishty

Human Robotics Laboratory, Department of Biomedical and Mechanical Engineering, University of Delaware, Newark, DE 19713 USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2021 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
HCHaider A. Chishty
Haider A. Chishty
AZAndrea Zonnino
Andrea Zonnino
AFAndria Farrens
Andria Farrens
FSFabrizio Sergi
Fabrizio Sergi
We present the UDiffWrist (UDW), a low-impedance 2-DOF wrist exoskeleton featuring a cable-differential transmission. To investigate the effect of different design strategies for achieving kinematic compatibility, we developed two versions of this robot: One version (UDW-C) achieves kinematic compatibility only in the case of perfect alignment between human and robot joints. The second version (UDW-NC) connects the human and robot via passive joints to achieve kinematic compatibility regardless of alignment between human and robot joints. Through characterization experiments, we found that the UDW-NC was more robust to misalignments than the UDW-C: the increase in maximum interaction torque associated with misalignments was greater for the UDW-C than the UDW-NC robot (p = 0.003). However, the UDW-NC displayed greater Coulomb friction (p < 0.001). Further, Coulomb friction increased more for the UDW-NC than the UDW-C in the presence of misalignments between the human and robot axes (p < 0.001). We also found that torque transfer was more accurate in the UDW-C than in the UDW-NC. These results suggest that for the small (10 deg) 2-DOF wrist movements considered, the advantages of the UDW-NC in terms of kinematic compatibility are likely overshadowed by the negative effects in friction and torque transfer accuracy.

23 March 2026 in bioRxiv
Verified
Preprint
Open access
HCHaider A. Chishty
Haider A. Chishty
ZLZion D. Lee
Zion D. Lee
UBUday Kiran Balaga
Uday Kiran Balaga
FSFabrizio Sergi
Fabrizio Sergi
Wearable devices for gravity balancing have high potential for impact across domains, including neuromotor rehabilitation and occupational systems. Devices made from compliant mechanisms, optimized to achieve specific compensation moments at target joints, have proven effective, but thus far have solely been optimized towards gravity compensation and not other wearability criteria. In this work, we propose a multi-objective optimization framework, based on particle swarm optimization, to design a soft, gravity balancing shoulder orthosis, while taking into account wearability constraints such as undesired loading directions and device size. Using this custom framework, we pursued multiple stages of orthosis design and optimization, selecting multiple solutions to be translated to real-world prototypes. These solutions were realized via 3D printing with thermoplastic polyurethane and evaluated for mechanical performance on benchtop and in-vivo. In-vivo testing on 6 healthy individuals demonstrated relative reductions in muscle activity for the anterior deltoid and upper trapezius, by 53 % and 71 % respectively when operating the orthosis for static tasks within functional shoulder ranges of motion. Changes in muscle activation were also were observed across other muscles, including the posterior deltoid, as well as in dynamic tasks at different speeds.

21 February 2024 in bioRxiv
Verified
Preprint
Open access
PDF file
HCHaider A. Chishty
Haider A. Chishty
FSFabrizio Sergi
Fabrizio Sergi
Flexion-synergy is a stereotypical movement pattern that inhibits independent joint control for those who have been affected by stroke; this abnormal co-activation of elbow flexors with shoulder abductors significantly reduces range of motion when reaching against gravity. While wearable orthoses based around compliant mechanisms have been shown to accurately compensate for the arm at the shoulder, it is unclear if accurate compensation can also be achieved while minimizing device bulk. In this work, we present a novel, multi-objective simulation-optimization framework towards the goal of designing practical gravity-balancing orthoses for the upper-limb. Our framework includes a custom built VB.NET application to run nonlinear finite element simulations in SolidWorks, and interfaces with a MATLAB-based particle swarm optimizer modified for multiple objectives. The framework is able to identify a set of Pareto-optimal compliant mechanism designs, confirming that compensation accuracy and protrusion minimization are indeed conflicting design objectives. The preliminary execution of the simulation-optimization framework demonstrates a capability of achieving designs that compensate for almost 90% of the arm’s gravity or that exhibit an average protrusion of less than 5% of the arm length, with different trade-offs between these two objectives.