27 October 2021 in IEEE Transactions on Medical Robotics and Bionics
We present the UDiffWrist (UDW), a low-impedance 2-DOF wrist exoskeleton featuring a cable-differential transmission. To investigate the effect of different design strategies for achieving kinematic compatibility, we developed two versions of this robot: One version (UDW-C) achieves kinematic compatibility only in the case of perfect alignment between human and robot joints. The second version (UDW-NC) connects the human and robot via passive joints to achieve kinematic compatibility regardless of alignment between human and robot joints. Through characterization experiments, we found that the UDW-NC was more robust to misalignments than the UDW-C: the increase in maximum interaction torque associated with misalignments was greater for the UDW-C than the UDW-NC robot (p = 0.003). However, the UDW-NC displayed greater Coulomb friction (p < 0.001). Further, Coulomb friction increased more for the UDW-NC than the UDW-C in the presence of misalignments between the human and robot axes (p < 0.001). We also found that torque transfer was more accurate in the UDW-C than in the UDW-NC. These results suggest that for the small (10 deg) 2-DOF wrist movements considered, the advantages of the UDW-NC in terms of kinematic compatibility are likely overshadowed by the negative effects in friction and torque transfer accuracy.
21 February 2024 in bioRxiv
Flexion-synergy is a stereotypical movement pattern that inhibits independent joint control for those who have been affected by stroke; this abnormal co-activation of elbow flexors with shoulder abductors significantly reduces range of motion when reaching against gravity. While wearable orthoses based around compliant mechanisms have been shown to accurately compensate for the arm at the shoulder, it is unclear if accurate compensation can also be achieved while minimizing device bulk. In this work, we present a novel, multi-objective simulation-optimization framework towards the goal of designing practical gravity-balancing orthoses for the upper-limb. Our framework includes a custom built VB.NET application to run nonlinear finite element simulations in SolidWorks, and interfaces with a MATLAB-based particle swarm optimizer modified for multiple objectives. The framework is able to identify a set of Pareto-optimal compliant mechanism designs, confirming that compensation accuracy and protrusion minimization are indeed conflicting design objectives. The preliminary execution of the simulation-optimization framework demonstrates a capability of achieving designs that compensate for almost 90% of the arm’s gravity or that exhibit an average protrusion of less than 5% of the arm length, with different trade-offs between these two objectives.