8 November 2018 in Risk Analysis
Space weather phenomena have been studied in detail in the peer‐reviewed scientific literature. However, there has arguably been scant analysis of the potential socioeconomic impacts of space weather, despite a growing gray literature from different national studies, of varying degrees of methodological rigor. In this analysis, we therefore provide a general framework for assessing the potential socioeconomic impacts of critical infrastructure failure resulting from geomagnetic disturbances, applying it to the British high‐voltage electricity transmission network. Socioeconomic analysis of this threat has hitherto failed to address the general geophysical risk, asset vulnerability, and the network structure of critical infrastructure systems. We overcome this by using a three‐part method that includes (i) estimating the probability of intense magnetospheric substorms, (ii) exploring the vulnerability of electricity transmission assets to geomagnetically induced currents, and (iii) testing the socioeconomic impacts under different levels of space weather forecasting. This has required a multidisciplinary approach, providing a step toward the standardization of space weather risk assessment. We find that for a Carrington‐sized 1‐in‐100‐year event with no space weather forecasting capability, the gross domestic product loss to the United Kingdom could be as high as £15.9 billion, with this figure dropping to £2.9 billion based on current forecasting capability. However, with existing satellites nearing the end of their life, current forecasting capability will decrease in coming years. Therefore, if no further investment takes place, critical infrastructure will become more vulnerable to space weather. Additional investment could provide enhanced forecasting, reducing the economic loss for a Carrington‐sized 1‐in‐100‐year event to £0.9 billion.
30 October 2017 in Space Weather
20 June 2018 in Space Weather
During space weather events, geomagnetically induced currents (GICs) can be induced in high‐voltage transmission networks, damaging individual transformers within substations. A common approach to modeling a transmission network has been to assume that every substation can be represented by a single resistance to Earth. We have extended that model by building a transformer‐level network representation of New Zealand's South Island transmission network. We represent every transformer winding at each earthed substation in the network by its known direct current resistance. Using this network representation significantly changes the GIC hazard assessment, compared to assessments based on the earlier assumption. Further, we have calculated the GIC flowing through a single phase of every individual transformer winding in the network. These transformer‐level GIC calculations show variation in GICs between transformers within a substation due to transformer characteristics and connections. The transformer‐level GIC calculations alter the hazard assessment by up to an order of magnitude in some places. In most cases the calculated GIC variations match measured variations in GIC flowing through the same transformers. This comparison with an extensive set of observations demonstrates the importance of transformer‐level GIC calculations in models used for hazard assessment.
27 December 2022 in Space Weather
Geomagnetically induced currents (GICs) are induced in electrical power transmission networks during geomagnetic disturbances. Understanding the magnitude and duration of the GIC expected during worst‐case extreme storm scenarios is vital to estimate potential damages and disruptions to power networks. In this study we utilize the magnetic field waveforms measured during three large geomagnetic storms and scale them to expected worst case extreme storm magnitudes. Multiple methods are used to simulate the varying magnitude of the magnetic field across the different latitudes of New Zealand. Modeled GIC is produced for nine extreme storm scenarios, each covering 1–1.5 days in duration. Our industry partners, Transpower New Zealand Ltd provided GIC magnitude and duration levels which represent a risk to their transformers. Using these thresholds various extreme storm scenarios predict between 44 and 115 New Zealand transformers (13%–35%) are at risk of damaging levels of GIC. The transformers at risk are largely independent of the extreme storm time‐variations, but depend more on the latitude variation scenario. We show that these at‐risk transformers are not localized to any specific region of New Zealand but extend across all regions and include most of the major population centers. A peak mean absolute GIC over a 60‐min window of 920–2,210 A and an instantaneous 1‐min time resolution maximum GIC of 1,590–4,920 A occurs for a worst‐case extreme storm scenario. We believe this is one of the first studies to combine a reasonable worst‐case extreme geomagnetic storm with validated GIC modeling and industry‐provided GIC risk thresholds.
18 June 2021 in Journal of Space Weather and Space Climate
Significant geoelectric fields are produced by the interaction of rapidly varying magnetic fields with the conductive Earth, particularly during intense geomagnetic activity. Though usually harmless, large or sustained geoelectric fields can damage grounded infrastructure such as high-voltage transformers and pipelines via geomagnetically induced currents (GICs). A key aspect of understanding the effects of space weather on grounded infrastructure is through the spatial and temporal variation of the geoelectric field. Globally, there are few long-term monitoring sites of the geoelectric field, so in 2012 measurements of the horizontal surface field were started at Lerwick, Eskdalemuir and Hartland observatories in the UK. Between 2012 and 2020, the maximum value of the geoelectric field observed was around 1 V/km in Lerwick, 0.5 V/km in Eskdalemuir and 0.1 V/km in Hartland during the March 2015 storm. These long-term observations also allow comparisons with models of the geoelectric field to be made. We use the measurements to compute magnetotelluric impedance transfer functions at each observatory for periods from 20 to 30,000 s. These are then used to predict the geoelectric field at the observatory sites during selected storm times that match the recorded fields very well (correlation around 0.9). We also compute geoelectric field values from a thin-sheet model of Britain, accounting for the diverse geological and bathymetric island setting. We find the thin-sheet model captures the peak and phase of the band-passed geoelectric field reasonably well, with linear correlation of around 0.4 in general. From these two modelling approaches, we generate geoelectric field values for historic storms (March 1989 and October 2003) and find the estimates of past peak geoelectric fields of up to 1.75 V/km in Eskdalemuir. However, evidence from high voltage transformer GIC measurements during these storms suggests these estimates are likely to represent an underestimate of the true value.
5 February 2019 in Space Weather
Geoelectric fields at the Earth's surface caused by geomagnetic storms have the potential to disrupt and damage ground‐based infrastructure such as electrical power distribution networks, pipelines, and railways. Here we model geoelectric fields in Ireland and the UK during both quiet and active time intervals of geomagnetic conditions using measurements from magnetic observatories and electromagnetic tensor relationships. The analysis focused on (1) defining periods of the magnetic field variations that are largely affected by the geomagnetic storms, between 30 and 30,000 s; (2) constraining the electromagnetic tensor relationships that defines the Earth's response to magnetic field variations; (3) implementing and validating two approaches for modeling geoelectric fields based on measurements from magnetic observatories and local and interstation electromagnetic transfer functions; and (4) estimating uncertainties when modeling geoelectric fields. The use of interstation tensor relationships allowed us to differentiate between regional and local geomagnetic sources. We found coherence values of 0.5–0.95, signal‐to‐noise ratio of 1–15 dB, normalized root‐mean‐square values of 0.8–3.4, and root‐mean‐square values of 0.7–84 mV/km. Within these ranges of values, sites in close proximity (<100 km) to a magnetic observatory and not affected by local storms will provide the most accurate results, while sites located at further distances and affected by spatially localized features of the storm will be less accurate. These methods enable us to more accurately model geomagnetically induced currents, and their associated uncertainties, in the British and Irish power networks.