Daniel H. Mac Manus

Daniel H. Mac Manus

Auto-generated profile, based on publicly available information

Daniel H. Mac Manus

Department of Physics University of Otago Dunedin New Zealand

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 August 2017 in Space Weather
Verified
Journal Article
Closed access
PDF file
DMDaniel H. Mac Manus
Daniel H. Mac Manus
CRCraig J. Rodger
Craig J. Rodger
MDMichael Dalzell
Michael Dalzell
ATAlan W. P. Thomson
Alan W. P. Thomson
MCMark A. Clilverd
Mark A. Clilverd
TDTim Divett
Tim Divett

13 October 2017 in Space Weather
Verified
Journal Article
Open access
PDF file
CRCraig J. Rodger
Craig J. Rodger
DMDaniel H. Mac Manus
Daniel H. Mac Manus
MDMichael Dalzell
Michael Dalzell
ATAlan W. P. Thomson
Alan W. P. Thomson
ECEllen Clarke
Ellen Clarke
TDTim Divett
Tim Divett
Geomagnetically induced current (GIC) observations made in New Zealand over 14 years show induction effects associated with a rapidly varying horizontal magnetic field (dBH/dt) during geomagnetic storms. This study analyzes the GIC observations in order to estimate the impact of extreme storms as a hazard to the power system in New Zealand. Analysis is undertaken of GIC in transformer number six in Islington, Christchurch (ISL M6), which had the highest observed currents during the 6 November 2001 storm. Using previously published values of 3,000 nT/min as a representation of an extreme storm with 100 year return period, induced currents of ~455 A were estimated for Islington (with the 95% confidence interval range being ~155–605 A). For 200 year return periods using 5,000 nT/min, current estimates reach ~755 A (confidence interval range 155–910 A). GIC measurements from the much shorter data set collected at transformer number 4 in Halfway Bush, Dunedin, (HWB T4), found induced currents to be consistently a factor of 3 higher than at Islington, suggesting equivalent extreme storm effects of ~460–1,815 A (100 year return) and ~460–2,720 A (200 year return). An estimate was undertaken of likely failure levels for single‐phase transformers, such as HWB T4 when it failed during the 6 November 2001 geomagnetic storm, identifying that induced currents of ~100 A can put such transformer types at risk of damage. Detailed modeling of the New Zealand power system is therefore required to put this regional analysis into a global context.

19 June 2018 in Space Weather
Verified
Journal Article
Open access
PDF file
MCMark A. Clilverd
Mark A. Clilverd
CRCraig J. Rodger
Craig J. Rodger
JBJames B. Brundell
James B. Brundell
MDMichael Dalzell
Michael Dalzell
IMIan Martin
Ian Martin
YOYuki Obana
Yuki Obana
Several periods of geomagnetically induced currents (GICs) were detected in the Halfway Bush substation in Dunedin, South Island, New Zealand, as a result of intense geomagnetic storm activity during 6 to 9 September 2017. Unprecedented data coverage from a unique combination of instrumentation is analyzed, that is, measurements of GIC on the single‐phase bank transformer T4 located within the substation, nearby magnetic field perturbation measurements, very low frequency (VLF) wideband measurements detecting the presence of power system harmonics, and high‐voltage harmonic distortion measurements. Two solar wind shocks occurred within 25 hr, generating four distinct periods of GIC. Two of the GIC events were associated with the arrival of the shocks themselves. These generated large but short‐lived GIC effects that resulted in no observable harmonic generation. Nearby and more distant magnetometers showed good agreement in measuring these global‐scale magnetic field perturbations. However, two subsequent longer‐lasting GIC periods, up to 30 min in duration, generated harmonics detected by the VLF receiver systems, when GIC levels continuously exceeded 15 A in T4. Nearby and more distant magnetometers showed differences in their measurements of the magnetic field perturbations at these times, suggesting the influence of small‐scale ionospheric current structures close to Dunedin. VLF receiver systems picked up harmonics from the substation, up to the 30th harmonic, consistent with observed high‐voltage increases in even harmonic distortion, along with small decreases in odd harmonic distortion.

20 June 2018 in Space Weather
Verified
Journal Article
Open access
PDF file
TDT. Divett
T. Divett
GRG. S. Richardson
G. S. Richardson
CBC. D. Beggan
C. D. Beggan
CRC. J. Rodger
C. J. Rodger
DBD. H. Boteler
D. H. Boteler
MDM. Dalzell
M. Dalzell
During space weather events, geomagnetically induced currents (GICs) can be induced in high‐voltage transmission networks, damaging individual transformers within substations. A common approach to modeling a transmission network has been to assume that every substation can be represented by a single resistance to Earth. We have extended that model by building a transformer‐level network representation of New Zealand's South Island transmission network. We represent every transformer winding at each earthed substation in the network by its known direct current resistance. Using this network representation significantly changes the GIC hazard assessment, compared to assessments based on the earlier assumption. Further, we have calculated the GIC flowing through a single phase of every individual transformer winding in the network. These transformer‐level GIC calculations show variation in GICs between transformers within a substation due to transformer characteristics and connections. The transformer‐level GIC calculations alter the hazard assessment by up to an order of magnitude in some places. In most cases the calculated GIC variations match measured variations in GIC flowing through the same transformers. This comparison with an extensive set of observations demonstrates the importance of transformer‐level GIC calculations in models used for hazard assessment.

27 December 2022 in Space Weather
Verified
Journal Article
Open access
DMD. H. Mac Manus
D. H. Mac Manus
CRC. J. Rodger
C. J. Rodger
MDM. Dalzell
M. Dalzell
ARA. Renton
A. Renton
GRG. S. Richardson
G. S. Richardson
MCM. A. Clilverd
M. A. Clilverd
Geomagnetically induced currents (GICs) are induced in electrical power transmission networks during geomagnetic disturbances. Understanding the magnitude and duration of the GIC expected during worst‐case extreme storm scenarios is vital to estimate potential damages and disruptions to power networks. In this study we utilize the magnetic field waveforms measured during three large geomagnetic storms and scale them to expected worst case extreme storm magnitudes. Multiple methods are used to simulate the varying magnitude of the magnetic field across the different latitudes of New Zealand. Modeled GIC is produced for nine extreme storm scenarios, each covering 1–1.5 days in duration. Our industry partners, Transpower New Zealand Ltd provided GIC magnitude and duration levels which represent a risk to their transformers. Using these thresholds various extreme storm scenarios predict between 44 and 115 New Zealand transformers (13%–35%) are at risk of damaging levels of GIC. The transformers at risk are largely independent of the extreme storm time‐variations, but depend more on the latitude variation scenario. We show that these at‐risk transformers are not localized to any specific region of New Zealand but extend across all regions and include most of the major population centers. A peak mean absolute GIC over a 60‐min window of 920–2,210 A and an instantaneous 1‐min time resolution maximum GIC of 1,590–4,920 A occurs for a worst‐case extreme storm scenario. We believe this is one of the first studies to combine a reasonable worst‐case extreme geomagnetic storm with validated GIC modeling and industry‐provided GIC risk thresholds.

1 July 2020 in Space Weather
Verified
Journal Article
Open access
PDF file
TDT. Divett
T. Divett
DMD. H. Mac Manus
D. H. Mac Manus
GRG. S. Richardson
G. S. Richardson
CBC. D. Beggan
C. D. Beggan
CRC. J. Rodger
C. J. Rodger
YOY. Obana
Y. Obana
Geomagnetically induced currents (GICs) during a space weather event have previously caused transformer damage in New Zealand. During the 2015 St. Patrick's Day Storm, Transpower NZ Ltd has reliable GIC measurements at 23 different transformers across New Zealand's South Island. These observed GICs show large variability, spatially and within a substation. We compare these GICs with those calculated from a modeled geolectric field using a network model of the transmission network with industry‐provided line, earthing, and transformer resistances. We calculate the modeled geoelectric field from the spectra of magnetic field variations interpolated from measurements during this storm and ground conductance using a thin‐sheet model. Modeled and observed GIC spectra are similar, and coherence exceeds the 95% confidence threshold, for most valid frequencies at 18 of the 23 transformers. Sensitivity analysis shows that modeled GICs are most sensitive to variation in magnetic field input, followed by the variation in land conductivity. The assumption that transmission lines follow straight lines or getting the network resistances exactly right is less significant. Comparing modeled and measured GIC time series highlights that this modeling approach is useful for reconstructing the timing, duration, and relative magnitude of GIC peaks during sudden commencement and substorms. However, the model significantly underestimates the magnitude of these peaks, even for a transformer with good spectral match. This is because of the limited range of frequencies for which the thin‐sheet model is valid and severely limits the usefulness of this modeling approach for accurate prediction of peak GICs.