Tim Divett

Tim Divett

Auto-generated profile, based on publicly available information

Tim Divett

School of Chemical and Physical Sciences Victoria University of Wellington Wellington New Zealand

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
RVRoss Vennell
Ross Vennell
SFSimon W. Funke
Simon W. Funke
SDScott Draper
Scott Draper
CSCraig Stevens
Craig Stevens
TDTim Divett
Tim Divett

5 August 2017 in Space Weather
Verified
Journal Article
Closed access
PDF file
DMDaniel H. Mac Manus
Daniel H. Mac Manus
CRCraig J. Rodger
Craig J. Rodger
MDMichael Dalzell
Michael Dalzell
ATAlan W. P. Thomson
Alan W. P. Thomson
MCMark A. Clilverd
Mark A. Clilverd
TDTim Divett
Tim Divett

13 October 2017 in Space Weather
Verified
Journal Article
Open access
PDF file
CRCraig J. Rodger
Craig J. Rodger
DMDaniel H. Mac Manus
Daniel H. Mac Manus
MDMichael Dalzell
Michael Dalzell
ATAlan W. P. Thomson
Alan W. P. Thomson
ECEllen Clarke
Ellen Clarke
TDTim Divett
Tim Divett
Geomagnetically induced current (GIC) observations made in New Zealand over 14 years show induction effects associated with a rapidly varying horizontal magnetic field (dBH/dt) during geomagnetic storms. This study analyzes the GIC observations in order to estimate the impact of extreme storms as a hazard to the power system in New Zealand. Analysis is undertaken of GIC in transformer number six in Islington, Christchurch (ISL M6), which had the highest observed currents during the 6 November 2001 storm. Using previously published values of 3,000 nT/min as a representation of an extreme storm with 100 year return period, induced currents of ~455 A were estimated for Islington (with the 95% confidence interval range being ~155–605 A). For 200 year return periods using 5,000 nT/min, current estimates reach ~755 A (confidence interval range 155–910 A). GIC measurements from the much shorter data set collected at transformer number 4 in Halfway Bush, Dunedin, (HWB T4), found induced currents to be consistently a factor of 3 higher than at Islington, suggesting equivalent extreme storm effects of ~460–1,815 A (100 year return) and ~460–2,720 A (200 year return). An estimate was undertaken of likely failure levels for single‐phase transformers, such as HWB T4 when it failed during the 6 November 2001 geomagnetic storm, identifying that induced currents of ~100 A can put such transformer types at risk of damage. Detailed modeling of the New Zealand power system is therefore required to put this regional analysis into a global context.

28 February 2013 in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
Verified
Journal Article
Closed access
PDF file
TDT Divett
T Divett
RVRoss Vennell
Ross Vennell
CSC Stevens
C Stevens
At tidal energy sites, large arrays of hundreds of turbines will be required to generate economically significant amounts of energy. Owing to wake effects within the array, the placement of turbines within will be vital to capturing the maximum energy from the resource. This study presents preliminary results using Gerris, an adaptive mesh flow solver, to investigate the flow through four different arrays of 15 turbines each. The goal is to optimize the position of turbines within an array in an idealized channel. The turbines are represented as areas of increased bottom friction in an adaptive mesh model so that the flow and power capture in tidally reversing flow through large arrays can be studied. The effect of oscillating tides is studied, with interesting dynamics generated as the tidal current reverses direction, forcing turbulent flow through the array. The energy removed from the flow by each of the four arrays is compared over a tidal cycle. A staggered array is found to extract 54 per cent more energy than a non-staggered array. Furthermore, an array positioned to one side of the channel is found to remove a similar amount of energy compared with an array in the centre of the channel.


20 June 2018 in Space Weather
Verified
Journal Article
Open access
PDF file
TDT. Divett
T. Divett
GRG. S. Richardson
G. S. Richardson
CBC. D. Beggan
C. D. Beggan
CRC. J. Rodger
C. J. Rodger
DBD. H. Boteler
D. H. Boteler
MDM. Dalzell
M. Dalzell
During space weather events, geomagnetically induced currents (GICs) can be induced in high‐voltage transmission networks, damaging individual transformers within substations. A common approach to modeling a transmission network has been to assume that every substation can be represented by a single resistance to Earth. We have extended that model by building a transformer‐level network representation of New Zealand's South Island transmission network. We represent every transformer winding at each earthed substation in the network by its known direct current resistance. Using this network representation significantly changes the GIC hazard assessment, compared to assessments based on the earlier assumption. Further, we have calculated the GIC flowing through a single phase of every individual transformer winding in the network. These transformer‐level GIC calculations show variation in GICs between transformers within a substation due to transformer characteristics and connections. The transformer‐level GIC calculations alter the hazard assessment by up to an order of magnitude in some places. In most cases the calculated GIC variations match measured variations in GIC flowing through the same transformers. This comparison with an extensive set of observations demonstrates the importance of transformer‐level GIC calculations in models used for hazard assessment.