Reverberation chambers create a statistical uniformly distributed field which is very useful for shielding effectiveness measurements. Two adjacent reverberation chambers made of flexible cloth have been developed and are used for shielding effectiveness measurements. The field stirring is achieved by moving the (angle of) the walls. The common wall of the adjacent chambers forms the interface where many different types of materials and structures can be exposed to high field strength. Any leakage in the other chamber is reflected multiple times. This setup makes it possible to achieve a very high dynamic range. A main advantage of this technique compared to the nested reverberation set-up is that measurements can be conducted much faster, and at much lower frequency.
12 June 2025 in IEEE Transactions on Electromagnetic Compatibility
This article presents a comprehensive analysis of the near-field, low-frequency shielding effectiveness characterization of planar materials. The influence of several parameters, including the orientation of the loops (e.g., coplanar versus parallel), distance between the loop and the sample, sample size, and the method of mounting the sample on a shielded cage wall (opening), is investigated. The study employs both measurements and numerical simulations using the low-frequency Finite-Element Method to assess shielding effectiveness over a frequency range of 9 kHz to 10 MHz. The results demonstrate a strong correlation between the measured and simulated shielding effectiveness. Furthermore, the findings indicate that the impact of each parameter varies depending on the orientation of the loops. Based on these insights, the article provides best practices for accurately characterizing the shielding effectiveness of planar materials in the low-frequency range.
19 March 2025 in IEEE Transactions on Electromagnetic Compatibility
One key technique in electromagnetic compatibility is shielding, which serves to create a barrier between different electromagnetic (EM) zones. The EM shielding of a cabinet determines the radiated emission (RE) outside the enclosure based on the contents inside. This article evaluates the shielding effectiveness (SE) of a commercial off-the-shelf (COTS) 19-in cabinet partially filled with COTS equipment, which represents an actual functional cabinet. RE measurements and SE determinations based on these RE results have been conducted on this enclosure. The different RE results from an open (side panels and door removed) and closed cabinet were used to determine its SE. These RE results, along with the determined SE values, are presented and compared with the SE results of an empty 19-in cabinet. Furthermore, the results are compared with SE results obtained using an intentional source inside the partially filled enclosure. This RE and SE evaluation is applicable to other Faraday cage-like enclosures, such as cars, buses, airplanes, ships, satellites, TEMPEST cabinets, and shielded rooms.
13 September 2022 in IEEE Transactions on Electromagnetic Compatibility
This article presents the degradation effects of long-term use of a dual vibrating intrinsic reverberation chamber (dual VIRC) for shielding effectiveness (SE) measurements. At the beginning with a new fresh dual VIRC setup it is possible to achieve a very high dynamic range (DR) but the DR degrades due to long-term use of the dual VIRC. The effect of 10 years use of the dual VIRC on the DR is shown as function of usage time. Also, the effect on the DR of a new dual VIRC with better conductive cloth has been presented.
This paper presents the effect of a reflective environment of the dual vibrating intrinsic reverberation chamber (dual VIRC) on the dynamic range (DR) for shielding effectiveness (SE) measurements. The DR of the same dual VIRC setup is shown for different reflective environments. The effect of leakage of the cloth material of the dual VIRC on the DR in such a reflective environment has been investigated too.
16 April 2026 in IEEE Transactions on Electromagnetic Compatibility
Effective shielding is crucial for a range of applications, such as safeguarding information-sensitive systems and providing protection against the effects of high-altitude, nuclear, or lightning-induced electromagnetic pulses. Since the deterioration of the shield can have serious consequences, real-time monitoring is critical to ensure the continuous shielding integrity. Conventional shielding effectiveness measurement techniques are limited to periodic evaluations, making them unsuitable for real-time monitoring. Furthermore, conventional shielding effectiveness measurements rely on high field strength electromagnetic signals which are not desired for continuous assessment. This article proposes a passive shielding integrity monitoring method particularly designed for on-site conditions, using signals-of-opportunity and software-defined radio-based receivers. Unlike conventional methods, due to its small footprint, the proposed method is able to be applied in operational enclosures with contents. Experimental results have shown the feasibility and adaptability of the proposed method. The proposed method allows the bridging between periodic evaluations and real-time monitoring and helps in mitigating the risks associated with the potential electromagnetic leakage of interfering signals or compromising emanations, thereby significantly enhancing information security for sensitive environments and critical infrastructure.