This article presents a Pearson's random walk approach for modelling the electromagnetic emissions of $N$ parallel connected power electronic converters. For the first time, a methodology that enables testing the random walk approach is presented. This methodology is validated in two ways: firstly, via simulations of a simplified setup consisting of 8 half-bridge power electronic converters. Secondly, it is validated with the use of an experimental setup consisting of 3 dc/dc converters. The verification is done in the complex domain, as well as by comparing the magnitude of the common mode current via the theoretical cumulative distribution function and the empirical cumulative distribution function. Finally, the probability of electromagnetic interference reduction at a specific harmonic of the switching frequency is derived.
19 May 2022 in IEEE Transactions on Power Electronics
In many papers, random modulation of power electronic converters is described as an electromagnetic interference (EMI) mitigation technique, which contributes to the assurance of electromagnetic compatibility (EMC) of systems consisting of power electronic converters and serial transmission-based control and measuring devices. However, experimental results as well as theoretical analyses of physical phenomenon suggest that the EMI reduction is ostensible and results from the measuring procedure adopted in standards. This article presents the first known approach to compare the influence of deterministic and random modulation of transmission errors rate in serial communication systems. The comparison is based on the especially developed mathematical models, which are validated experimentally, using a simple setup with a dc/dc converter injecting a noise into the USB/RS232 converter representing a serial transmission scheme. The comparison reveals that for the studied switching frequency range from 10 kHz to 1 MHz, on average, there is no significant difference between random and deterministic modulations with respect to the probability of error rate in serial communication systems. Thus, in such systems, random modulation should not be considered as a valid EMC-assuring technique.
16 April 2026 in IEEE Transactions on Electromagnetic Compatibility
Effective shielding is crucial for a range of applications, such as safeguarding information-sensitive systems and providing protection against the effects of high-altitude, nuclear, or lightning-induced electromagnetic pulses. Since the deterioration of the shield can have serious consequences, real-time monitoring is critical to ensure the continuous shielding integrity. Conventional shielding effectiveness measurement techniques are limited to periodic evaluations, making them unsuitable for real-time monitoring. Furthermore, conventional shielding effectiveness measurements rely on high field strength electromagnetic signals which are not desired for continuous assessment. This article proposes a passive shielding integrity monitoring method particularly designed for on-site conditions, using signals-of-opportunity and software-defined radio-based receivers. Unlike conventional methods, due to its small footprint, the proposed method is able to be applied in operational enclosures with contents. Experimental results have shown the feasibility and adaptability of the proposed method. The proposed method allows the bridging between periodic evaluations and real-time monitoring and helps in mitigating the risks associated with the potential electromagnetic leakage of interfering signals or compromising emanations, thereby significantly enhancing information security for sensitive environments and critical infrastructure.
Field Programmable Gate Arrays are essential components in applications, which require a certain degree of reconfigurability. This feature is achieved by a sea of configurable logic blocks, which realize the desired boolean functions. These blocks require interconnect lanes to realize more complex functions and to exchange data. In consequence, interconnect logic consumes a comparably large amount of each FPGA type, where multiplexers are an integral part. These components can be realized in different ways with different advantages and drawbacks. In this paper, selected multiplexer designs are compared to a versatile, newly developed, data retaining and power saving multiplexer design.
The aim of this paper is to explore the usage of different sampling schemes in order to build a sparse Polynomial Chaos (PC) model for prediction of the oscillation frequency and its corresponding magnitude of the output voltage in a half-bridge buck converter. The 22 parasitic elements of this converter are modelled as random variables following a uniform distribution. As a result, from the considered sampling schemes, an Latin Hypercube Sampling (LHS) and Sobol’ sequences are determined to be the best in prediction of the magnitude, both with respect to accuracy and computational time needed for the creation of the model. The introduced accuracy measure, namely the a posteriori error, shows that the PC model approximates the oscillation frequency well. However, from a visual comparison with a model obtained from 8000 Monte Carlo samples, it can be seen that the PC model is not able to handle such a complex relationship properly.
Mechanical buzzing in alternating current electromagnetic relays may result from internal defects such as core misalignment, mechanical deformation, debris in the air gap, or incomplete contact between mating surfaces. These faults disturb the magnetic conditions inside the relay and reduce proper force compensation. Existing diagnostic methods usually rely on acoustic testing during operation or destructive disassembly, which are time consuming, operator dependent, and unsuitable for large scale inspection. This paper presents a non destructive diagnostic approach based on X ray micro computed tomography. The method uses a normalized radial intensity profile deviation metric derived from the angular averaged intensity distribution of a specimen as a function of radius. It does not require a computer aided design model or machine learning training and depends only on a small reference group of confirmed healthy specimens. The method was tested on healthy and defective electromagnetic relays previously verified by acoustic examination. The proposed metrics enabled clear separation between healthy and damaged specimens. An additional root mean square based variant further improved discrimination by increasing the influence of localized anomalies in the air gap region and reducing the number of reference specimens needed for reliable classification. Additional analyses confirmed the robustness of the method and showed that the diagnostic signal in the gap region reflects a real geometric or material feature rather than a scanner artifact. Sensitivity analysis also confirmed that the air gap region is the main source of classification information.